a b s t r a c tPurpose: To determine whether voluntary deep-inspiratory breath-hold (v_DIBH) and deep-inspiratory breath-hold with the active breathing coordinator™ (ABC_DIBH) in patients undergoing left breast radiotherapy are comparable in terms of normal-tissue sparing, positional reproducibility and feasibility of delivery. Methods: Following surgery for early breast cancer, patients underwent planning-CT scans in v_DIBH and ABC_DIBH. Patients were randomised to receive one technique for fractions 1-7 and the second technique for fractions 8-15 (40 Gy/15 fractions total). Daily electronic portal imaging (EPI) was performed and matched to digitally-reconstructed radiographs. Cone-beam CT (CBCT) images were acquired for 6/15 fractions and matched to planning-CT data. Population systematic (R) and random errors (r) were estimated. Heart, left-anterior-descending coronary artery, and lung doses were calculated. Patient comfort, radiographer satisfaction and scanning/treatment times were recorded. Within-patient comparisons between the two techniques used the paired t-test or Wilcoxon signed-rank test. Results: Twenty-three patients were recruited. All completed treatment with both techniques. EPIderived R were 61.8 mm (v_DIBH) and 62.0 mm (ABC_DIBH) and r 62.5 mm (v_DIBH) and 62.2 mm (ABC_DIBH) (all p non-significant). CBCT-derived R were 63.9 mm (v_DIBH) and 64.9 mm (ABC_DIBH) and r 6 4.1 mm (v_DIBH) and 6 3.8 mm (ABC_DIBH). There was no significant difference between techniques in terms of normal-tissue doses (all p non-significant). Patients and radiographers preferred v_DIBH (p = 0.007, p = 0.03, respectively). Scanning/treatment setup times were shorter for v_DIBH (p = 0.02, p = 0.04, respectively). Conclusions: v_DIBH and ABC_DIBH are comparable in terms of positional reproducibility and normal tissue sparing. v_DIBH is preferred by patients and radiographers, takes less time to deliver, and is cheaper than ABC_DIBH.
This work is a feasibility study to use a four-dimensional computed tomography (4D CT) dataset generated by a continuous motion model for treatment planning in lung radiotherapy. The model-based 4D CT data were derived from multiple breathing cycles. Four patients were included in this retrospective study. Treatment plans were optimized at end-exhale for each patient and the effect of respiratory motion on the dose delivery investigated. The accuracy of the delivered dose as determined by the number of intermediate respiratory phases used for the calculation was considered. The time-averaged geometry of the anatomy representing the mid-ventilation phase of the breathing cycle was generated using the motion model and a treatment plan was optimized for this phase for one patient. With respiratory motion included, the mid-ventilation plan achieved better target coverage than the plan optimized at end-exhale when standard margins were used to expand the clinical target volume (CTV) to planning target volume (PTV). Using a margin to account for set-up uncertainty only, resulted in poorer target coverage and healthy tissue sparing. For this patient cohort, the results suggest that conventional three-dimensional treatment planning was sufficient to maintain target coverage despite respiratory motion. The motion model has proved a useful tool in 4D treatment planning.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.