Density gradient centrifugation is a high-resolution technique for the separation and characterization of large molecules and stable complexes. We have analyzed various nanotube structures by preparative centrifugation in sodium metatungstate-water solutions. Bundled, isolated and acid-treated single-walled nanotubes (SWNTs) and multiwall nanotubes (MWNTs) formed sharp bands at well-defined densities. The structure of the material in each band was confirmed by transmission electron microscopy and Raman spectroscopy. Our data suggest respective densities of 1.87, 2.13, 1.74, and 2.1 g/cm(3) for bundled, isolated, and acid-treated SWNTs and MWNTs. These measured results compare well with their calculated densities.
Optical imaging requires appropriate light sources. For image-guided surgery, in particular fluorescence-guided surgery, a high fluence rate, a long working distance, computer control, and precise control of wavelength are required. In this article, we describe the development of light-emitting diode (LED)-based light sources that meet these criteria. These light sources are enabled by a compact LED module that includes an integrated linear driver, heat dissipation technology, and real-time temperature monitoring. Measuring only 27 mm wide by 29 mm high and weighing only 14.7 g, each module provides up to 6,500 lx of white (400-650 nm) light and up to 157 mW of filtered fluorescence excitation light while maintaining an operating temperature < or = 50 degrees C. We also describe software that can be used to design multimodule light housings and an embedded processor that permits computer control and temperature monitoring. With these tools, we constructed a 76-module, sterilizable, three-wavelength surgical light source capable of providing up to 40,000 lx of white light, 4.0 mW/cm2 of 670 nm near-infrared (NIR) fluorescence excitation light, and 14.0 mW/cm2 of 760 nm NIR fluorescence excitation light over a 15 cm diameter field of view. Using this light source, we demonstrated NIR fluorescence-guided surgery in a large-animal model.
We report a new method of measuring the amplitude and phase of oscillations of individual multiwall carbon nanotubes (MWNTs). As in many other experiments, we excite the oscillations electrostatically, but we show that we can detect the amplitude and phase of the resulting oscillation electrically. As an example, we present measurements of the fundamental and first two overtones of the diving board resonance of a MWNT at 0.339, 2.42, and 5.31 MHz in ambient conditions. The corresponding quality factors were 67, 36, and 25.
Precise determination of the resonant frequency, phase, and quality factor in micromechanical and nanomechanical oscillators would permit, among other things, (i) the detection of trace amounts of adsorbed molecules through a shift in the resonant frequency, and (ii) pressure variations in the environment which affect the mechanical damping of the oscillator. The major difficulty in making these measurements in many cases is the ancillary equipment such as lasers or high magnetic fields that must be used. Being able to make precise measurements with a fully electrical actuation and detection method would greatly extend the usefulness of these oscillators. Detecting the oscillation through changes in the capacitance between the oscillator and a counter electrode is difficult because the static capacitance between them as well as the parasitic capacitance of the rest of the circuitry overwhelm the detection. We have found that the charge on a microcantilever or nanocantilever when driven by a nearby counter electrode contains higher harmonics of the driving signal with appreciable amplitude. This allows detection at frequencies well removed from the driving frequency, which increases the signal to background ratio by approximately three orders of magnitude. With this method, we show clear electrical detection of mechanical oscillations in ambient conditions for two systems: Si-based microcantilevers and multiwalled carbon nanotube based nanocantilevers.
We describe an integrated microwave imaging system that can provide spatial maps of dielectric properties of heterogeneous media with tomographically collected data. The hardware system (800-1200 MHz) was built based on a lock-in amplifier with 16 fixed antennas. The reconstruction algorithm was implemented using a Newton iterative method with combined Marquardt-Tikhonov regularizations. System performance was evaluated using heterogeneous media mimicking human breast tissue. Finite element method coupled with the Bayliss and Turkel radiation boundary conditions were applied to compute the electric field distribution in the heterogeneous media of interest. The results show that inclusions embedded in a 76-diameter background medium can be quantitatively reconstructed from both simulated and experimental data. Quantitative analysis of the microwave images obtained suggests that an inclusion of 14 mm in diameter is the smallest object that can be fully characterized presently using experimental data, while objects as small as 10 mm in diameter can be quantitatively resolved with simulated data.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.