Medications delivered by continuous infusion, particularly those that are weight based, can contribute to medication errors in the intensive care unit. A large proportion (87.6%) of doses for weight-based infusions was calculated based on estimated or unreliable admission weights. There were no severe consequences resulting from the errors observed in this 1 month investigation; however, depending on the pharmacokinetic characteristics of the drug being administered, there is a potential to deliver artificially low or high doses resulting in subtherapeutic or adverse effects.
The i.v. insulin infusion protocols developed and implemented in the ICUs at three institutions successfully achieved acceptance and compliance by physicians and nurses. The factors attributed to the success were multidisciplinary involvement, the continuous education of nursing staff, the vigilant involvement of a pharmacist, and flexibility in revising the protocol.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.