The end-tidal carbon dioxide partial pressure (PCO2) response curves for the flow velocity in the middle cerebral artery were studied in 31 normal subjects with transcranial Doppler techniques. An exponential curve with an exponent of 0.034 mm Hg-1 was found to be a good fit to the recorded data. By means of this relationship, recordings of flow velocity in cerebral arteries can be normalized to a standard value of PCO2. Physiological aspects of cerebrovascular reactivity to PCO2 and the clinical implications of the PCO2 response curve are discussed. The normal material provides a reference for assessing pathological responses.
Noninvasive transcranial Doppler recordings were correlated to the angiographic findings in 77 patients with carotid artery disease. Stenoses reducing the luminal area of the internal carotid artery by 75% or more also reduced the pulsatility transmission index (PTI) of the ipsilateral middle cerebral artery (MCA). The PTI is the pulsatility index of the artery under study expressed as a percent of the pulsatility index of another intracranial artery with presumed unimpeded inflow in the same individual. For stenoses in the 75% to 89% category. PTI reduction was significantly greater in patients with bilateral carotid stenosis, indicating an impaired potential for collateral flow in these patients. The PTI reduction probably reflects both the pressure drop across the stenosis and the cerebral autoregulatory response. Two criteria proved useful in demonstrating collateral MCA supply through the circle of Willis. On the recipient side, retrograde flow in the proximal anterior cerebral artery was demonstrated in 29 of the 31 patients when this flow pattern was disclosed angiographically. In 26 of these patients, the anterior cerebral artery on the supplying side also had clearly increased flow velocity. Increased flow velocities in the proximal posterior cerebral artery were present in 26 of the 30 vessels that were acting as a collateral channel to the ipsilateral MCA.
Results from 1,039 combined cervical and transcranial Doppler examinations are reported. Satisfactory transcranial signals were not found in 2.7% of the cases. Compared with angiography, the accuracy of transcranial criteria in assessing collateral flow over the circle of Willis was 94 and 88% for anterior and posterior circulation, respectively. The method also appeared very promising for detection of lesions of the intracranial arteries although the number of such cases with angiographic verification was limited in the present series. Arterial narrowing due to cerebral vasospasm was diagnosed with a sensitivity of 80%. In patients with ruptured intracranial aneurysms, an incidence of 93% arterial narrowing in basal cerebral arteries was found. Patients with subarachnold hemorrhage and no aneurysm on angiography also showed arterial narrowing with an incidence of 56%. It was possible to monitor the time course and severity of cerebral vasospasm. Arteriovenous malformations were characterized by Doppler findings of high velocities and low pulsatilities. These lesions were diagnosed with an accuracy of 95%. (Stroke 1987;18:1018-1024)
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.