Rationale: Isoforms I and II of the glycolytic enzyme hexokinase (HKI and HKII) are known to associate with mitochondria. It is unknown whether mitochondria-bound hexokinase is mandatory for ischemic preconditioning and normal functioning of the intact, beating heart. Objective: We hypothesized that reducing mitochondrial hexokinase would abrogate ischemic preconditioning and disrupt myocardial function. Methods and Results: Ex vivo perfused HKII؉/؊ hearts exhibited increased cell death after ischemia and reperfusion injury compared with wild-type hearts; however, ischemic preconditioning was unaffected. To investigate acute reductions in mitochondrial HKII levels, wild-type hearts were treated with a TAT control peptide or a TAT-HK peptide that contained the binding motif of HKII to mitochondria, thereby disrupting the mitochondrial HKII association. Mitochondrial hexokinase was determined by HKI and HKII immunogold labeling and electron microscopy analysis. Low-dose (200 nmol/L) TAT-HK treatment significantly decreased mitochondrial HKII levels without affecting baseline cardiac function but dramatically increased ischemiareperfusion injury and prevented the protective effects of ischemic preconditioning. Treatment for 15 minutes with high-dose (10 mol/L) TAT-HK resulted in acute mitochondrial depolarization, mitochondrial swelling, profound contractile impairment, and severe cardiac disintegration. The detrimental effects of TAT-HK treatment were mimicked by mitochondrial membrane depolarization after mild mitochondrial uncoupling that did not cause direct mitochondrial permeability transition opening. Conclusions:Acute low-dose dissociation of HKII from mitochondria in heart prevented ischemic preconditioning, whereas high-dose HKII dissociation caused cessation of cardiac contraction and tissue disruption, likely through an acute mitochondrial membrane depolarization mechanism. The results suggest that the association of HKII with mitochondria is essential for the protective effects of ischemic preconditioning and normal cardiac function through maintenance of mitochondrial potential. (Circ Res. 2011;108:1165-1169.)
Blood flow is distributed through the heart muscle via a system of vessels forming the coronary circulation. The perfusion of the myocardium can be hampered by atherosclerosis creating localized obstructions in the epicardial vessels or by microvascular disease. In early stages of the disease, these impediments to blood flow are offset by dilation of the resistance vessels, which normally compensates for a decrease in perfusion pressure or increased metabolism. However, this dilatory reserve can become exhausted, which in general occurs first at the deeper layers of the heart wall where intramural vessels are subjected to compressive forces related to heart contraction. In the catheterization laboratory, guide wires of 0.33 mm diameter are available that are equipped with a pressure and flow velocity sensor at the tip, which can be positioned distal to the stenosis. These signals provide information about the impediment of the stenosis on coronary flow and allow for the evaluation of the status of the microcirculation. However, the interpretation of these signals is strongly model-dependent and therefore it is of paramount importance to develop realistic models reflecting the anatomy and unique physiology of the coronary circulation.
Due to spectral overlap, the number of fluorescent labels for imaging cryomicrotome detection was limited to 4. The aim of this study was to increase the separation of fluorescent labels. In the new imaging cryomicrotome, the sample is cut in slices of 40 μm. Six images are taken for each cutting plane. Correction for spectral overlap is based on linear combinations of fluorescent images. Locations of microspheres are determined by using the system point spread function. Five differently colored microspheres were injected in vivo distributed over two major coronaries, the left anterior descending and left circumflex artery. Under absence of collateral flow, microspheres outside of target perfusion territories were not found and the procedure did not generate false positive detection when spectral overlap was relevant. In silico-generated microspheres were used to test the effect of background image, transparency correction, and color separation. The percentage of microspheres undetected was 2.3 ± 0.8% in the presence and 1.5 ± 0.4% in the absence of background structures with a density of 900 microspheres per color per cm3. The image analysis method presented here, allows for an increased number of experimental conditions that can be investigated in studies of regional myocardial perfusion.
The aim of this study was to develop a novel method to reconstruct 3-D coronary vasculature from cryomicrotome images, comprised of two distinct sets of data-fluorescent microsphere beads and coronary vasculature. Fluorescent beads and cast injected into the vasculature were separately imaged with different filter settings to obtain the microsphere and vascular data, respectively. To extract the vascular anatomy, light scattering in the tissue was modelled using a point spread function (PSF). The PSF was parametrized by optical tissue excitation and emission attenuation coefficients, which were estimated by fitting simulated images of microspheres convolved with the PSF model to the experimental microsphere images. These parameters were then applied within a new model-based method for vessel radius estimation. Current state-of-the-art radii estimation methods and the proposed model-based method were applied on vessel phantoms. In this validation study, the full-width half-maximum method of radii estimation, when performed on the raw data without correcting for the optical blurring, resulted in 42.9% error on average for the 170 μm vessel. In comparison, the model-based method resulted in 0.6% error on average for the same phantom. Whole-organ porcine coronary vasculature was automatically reconstructed with the new model-based vascular extraction method.
BackgroundCardiovascular Magnetic Resonance (CMR) myocardial perfusion imaging has the potential to evolve into a method allowing full quantification of myocardial blood flow (MBF) in clinical routine. Multiple quantification pathways have been proposed. However at present it remains unclear which algorithm is the most accurate. An isolated perfused, magnetic resonance (MR) compatible pig heart model allows very accurate titration of MBF and in combination with high-resolution assessment of fluorescently-labeled microspheres represents a near optimal platform for validation. We sought to investigate which algorithm is most suited to quantify myocardial perfusion by CMR at 1.5 and 3 Tesla using state of the art CMR perfusion techniques and quantification algorithms.MethodsFirst-pass perfusion CMR was performed in an MR compatible blood perfused pig heart model. We acquired perfusion images at physiological flow (“rest”), reduced flow (“ischaemia”) and during adenosine-induced hyperaemia (“hyperaemia”) as well as during coronary occlusion. Perfusion CMR was performed at 1.5 Tesla (n = 4 animals) and at 3 Tesla (n = 4 animals). Fluorescently-labeled microspheres and externally controlled coronary blood flow served as reference standards for comparison of different quantification strategies, namely Fermi function deconvolution (Fermi), autoregressive moving average modelling (ARMA), exponential basis deconvolution (Exponential) and B-spline basis deconvolution (B-spline).ResultsAll CMR derived MBF estimates significantly correlated with microsphere results. The best correlation was achieved with Fermi function deconvolution both at 1.5 Tesla (r = 0.93, p < 0.001) and at 3 Tesla (r = 0.9, p < 0.001). Fermi correlated significantly better with the microspheres than all other methods at 3 Tesla (p < 0.002). B-spline performed worse than Fermi and Exponential at 1.5 Tesla and showed the weakest correlation to microspheres (r = 0.74, p < 0.001). All other comparisons were not significant. At 3 Tesla exponential deconvolution performed worst (r = 0.49, p < 0.001).ConclusionsCMR derived quantitative blood flow estimates correlate with true myocardial blood flow in a controlled animal model. Amongst the different techniques, Fermi function deconvolution was the most accurate technique at both field strengths. Perfusion CMR based on Fermi function deconvolution may therefore emerge as a useful clinical tool providing accurate quantitative blood flow assessment.
Blood flow distribution within the myocardium and the location and extent of areas at risk in case of coronary artery disease are dependent on the distribution and morphology of intramural vascular crowns. Knowledge of the intramural vasculature is essential in novel multiscale and multiphysics modeling of the heart. For this study, eight canine hearts were analyzed with an imaging cryomicrotome, developed to acquire high-resolution spatial data on three-dimensional vascular structures. The obtained vasculature was skeletonized, and for each penetrating artery starting from the epicardium, the dependent vascular crown was defined. Three-dimensional Voronoi tessellation was applied with the end points of the terminal segments as center points. The centroid of end points in each branch allowed classification of the corresponding perfusion territories in subendocardial, midmyocardial, and subepicardial. Subendocardial regions have relatively few territories of about 0.5 ml in volume having their own penetrating artery at the epicardium, whereas the subepicardium is perfused by a multitude of small perfusion territories, in the order of 0.01 ml. Vascular volume density of small arteries up till 400 μm was 3.2% at the subendocardium territories but only 0.8% in the subepicardium territories. Their higher volume density corresponds to compensation for flow impeding forces by cardiac contraction. These density differences result in different scaling law properties of vascular volume and tissue mass per territory type. This novel three-dimensional quantitative analysis may form the basis for patient-specific computational models on coronary perfusion and aid the interpretation of image-based clinical methods for assessing the transmural perfusion distribution.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.