IntroductionTo compare the differences in setup errors measured with electronic portal image (EPI) and cone‐beam computed tomography (CBCT) in patients undergoing tangential breast radiotherapy (RT). Relationship between setup errors, body mass index (BMI) and breast size was assessed.MethodsTwenty‐five patients undergoing postoperative RT to the breast were consented for this study. Weekly CBCT scans were acquired and retrospectively registered to the planning CT in three dimensions, first using bony anatomy for bony registration (CBCT‐B) and again using breast tissue outline for soft tissue registration (CBCT‐S). Digitally reconstructed radiographs (DRR) generated from CBCT to simulate EPI were compared to the planning DRR using bony anatomy in the V (parallel to the cranio‐caudal axis) and U (perpendicular to V) planes. The systematic (Σ) and random (σ) errors were calculated and correlated with BMI and breast size.ResultsThe systematic and random errors for EPI (Σ V = 3.7 mm, Σ U = 2.8 mm and σ V = 2.9 mm, σ U = 2.5) and CBCT‐B (Σ V = 3.5 mm, Σ U = 3.4 mm and σ V = 2.8 mm, σ U = 2.8) were of similar magnitude in the V and U planes. Similarly, the differences in setup errors for CBCT‐B and CBCT‐S in three dimensions were less than 1 mm. Only CBCT‐S setup error correlated with BMI and breast size.Conclusions CBCT and EPI show insignificant variation in their ability to detect setup error. These findings suggest no significant differences that would make one modality considered superior over the other and EPI should remain the standard of care for most patients. However, there is a correlation with breast size, BMI and setup error as detected by CBCT‐S, justifying the use of CBCT‐S for larger patients.
To quantify the impact of treatment delivery uncertainties on lung stereotactic ablative body radiotherapy (SABR) plans for step-and-shoot intensity-modulated radiotherapy (ssIMRT) and volumetric modulated arc therapy (VMAT). Baseline ssIMRT and VMAT treatment plans were generated for a cohort of 18 lung SABR patients. Modified plans were generated for each baseline plan by systematically varying gantry and collimator angles between - 5 and + 5 degrees, as well as multi-leaf collimator (MLC) leaf position errors of magnitude between 1 and 5 mm in both directions (i.e. leaf banks shifted either in the same (Type 1) or opposite (Type 2) directions). Planning target volume (PTV), spinal cord and healthy lung dose-volume histogram (DVH) metrics were compared between the modified and baseline plans. Collimator and gantry angle uncertainties did not significantly impact any of the PTV DVH metrics considered. MLC shifts of 5 mm resulted in average V changes of [Formula: see text] (Type 1) and [Formula: see text] (Type 2) and average [Formula: see text] changes of [Formula: see text] (Type 1) and [Formula: see text] (Type 2) for ssIMRT and VMAT plans. Comparatively, MLC shifts of - 2 mm resulted in average [Formula: see text] changes of [Formula: see text] (Type 1) and [Formula: see text] (Type 2) and average [Formula: see text] changes of [Formula: see text] (Type 1) and [Formula: see text] (Type 2) for ssIMRT and VMAT plans. ssIMRT gantry angle uncertainties impacted spinal cord DVH metrics the most, with increases in [Formula: see text] of [Formula: see text] occurring for a 1 degree shift. Type 2 MLC modifications impacted all OAR DVH metrics substantially with differences in spinal cord [Formula: see text] (ssIMRT) and healthy lung [Formula: see text] (VMAT) exceeding [Formula: see text] for 5 mm shifts. Uncertainties in MLC leaf positions affected target and OAR DVH metrics more than collimator or gantry angle uncertainties for lung SABR plans. Less patient-to-patient variation occurred from delivery uncertainties in VMAT than ssIMRT.
University officials are increasingly considering selling alcoholic beverages at campus football stadiums. To inform this decision, we report on offenses occurring at a campus football stadium and surrounding community on game day weekends between 2009 and 2013. Campus police log data for 35 home football weekends were examined, accounting for 1,940 distinct incidents. There was a general upward trend in crime incidents. On average, 330 total crime incidents occurred when alcohol was not sold (2009-2011) compared to 475 annually when alcohol was sold (2012-2013). Liquor law violations and alcohol consumption by a minor were the two most frequently cited offenses. Liquor law violations (317) was highest after alcohol sales initiated. Police incidents were markedly higher when playing a traditional football rival at home. College administrators, health officials, athletic departments, and local law enforcement must work together to weigh the potential benefit of enhanced financial profit against the risk of increased alcohol-related crime.
Introduction Hypofractionated radiotherapy (RT) in the setting of early invasive breast cancer has been shown to have similar local control rates and cosmetic outcomes as conventionally fractionated RT. This study compares ipsilateral recurrence rates between hypofractionated and conventional RT, with and without a boost. The effect of hypofractionated RT and chest wall separation (CWS) on cosmetic outcome was also assessed. Methods All patients with ductal carcinoma in situ (DCIS) treated between 1998 and 2012 across two sites of a single cancer institution were retrospectively studied. Patients were analysed according to those receiving conventional RT (≤2 Gy per fraction) and those receiving hypofractionated RT (>2 Gy per fraction), as well as the presence or absence of a tumour bed boost. Data were collected through electronic medical records and local cancer registry. Cosmetic outcome was scored by physicians on a four‐point scale during clinical follow‐up appointments. Results One hundred and ninety‐seven patients were treated for DCIS during the study period. One hundred and forty‐one were treated with conventional RT, and 56 with hypofractionated RT. After a median follow up of 4.4 years, there were 12 ipsilateral recurrences, of which seven were invasive disease and five DCIS. Ten recurrences occurred in patients who received conventional RT (7.1% recurrence rate) and two in those who received hypofractionated RT (3.6% recurrence rate) (P = 0.48). Cosmetic outcomes were not significantly different between conventional and hypofractionated RT (P = 0.06). Conclusions Hypofractionation represents a suitable alternative for treating DCIS in the absence of randomised data.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.