Smoking cigarettes is a major risk factor in the development and progression of cardiovascular disease (CVD) and chronic obstructive pulmonary disease (COPD). Modified risk tobacco products (MRTPs) are being developed to reduce smoking-related health risks. The goal of this study was to investigate hallmarks of COPD and CVD over an 8-month period in apolipoprotein E-deficient mice exposed to conventional cigarette smoke (CS) or to the aerosol of a candidate MRTP, tobacco heating system (THS) 2.2. In addition to chronic exposure, cessation or switching to THS2.2 after 2 months of CS exposure was assessed. Engaging a systems toxicology approach, exposure effects were investigated using physiology and histology combined with transcriptomics, lipidomics, and proteomics. CS induced nasal epithelial hyperplasia and metaplasia, lung inflammation, and emphysematous changes (impaired pulmonary function and alveolar damage). Atherogenic effects of CS exposure included altered lipid profiles and aortic plaque formation. Exposure to THS2.2 aerosol (nicotine concentration matched to CS, 29.9 mg/m3) neither induced lung inflammation or emphysema nor did it consistently change the lipid profile or enhance the plaque area. Cessation or switching to THS2.2 reversed the inflammatory responses and halted progression of initial emphysematous changes and the aortic plaque area. Biological processes, including senescence, inflammation, and proliferation, were significantly impacted by CS but not by THS2.2 aerosol. Both, cessation and switching to THS2.2 reduced these perturbations to almost sham exposure levels. In conclusion, in this mouse model cessation or switching to THS2.2 retarded the progression of CS-induced atherosclerotic and emphysematous changes, while THS2.2 aerosol alone had minimal adverse effects.
While the toxicity of the main constituents of electronic cigarette (ECIG) liquids, nicotine, propylene glycol (PG), and vegetable glycerin (VG), has been assessed individually in separate studies, limited data on the inhalation toxicity of them is available when in mixtures. In this 90-day subchronic inhalation study, Sprague-Dawley rats were nose-only exposed to filtered air, nebulized vehicle (saline), or three concentrations of PG/VG mixtures, with and without nicotine. Standard toxicological endpoints were complemented by molecular analyses using transcriptomics, proteomics, and lipidomics. Compared with vehicle exposure, the PG/VG aerosols showed only very limited biological effects with no signs of toxicity. Addition of nicotine to the PG/VG aerosols resulted in effects in line with nicotine effects observed in previous studies, including up-regulation of xenobiotic enzymes (Cyp1a1/Fmo3) in the lung and metabolic effects, such as reduced serum lipid concentrations and expression changes of hepatic metabolic enzymes. No toxicologically relevant effects of PG/VG aerosols (up to 1.520 mg PG/L + 1.890 mg VG/L) were observed, and no adverse effects for PG/VG/nicotine were observed up to 438/544/6.6 mg/kg/day. This study demonstrates how complementary systems toxicology analyses can reveal, even in the absence of observable adverse effects, subtoxic and adaptive responses to pharmacologically active compounds such as nicotine.
Various electronic nicotine delivery systems (ENDS), of which electronic cigarettes (e-cigs) are the most recognized prototype, have been quickly gaining ground on conventional cigarettes because they are perceived as less harmful. Research assessing the potential effects of ENDS exposure in humans is currently limited and inconclusive. New products are emerging with numerous variations in designs and performance parameters within and across brands. Acknowledging these challenges, we present here a proposed framework for an in vitro systems toxicology assessment of e-liquids and their aerosols, intended to complement the battery of assays for standard toxicity assessments. The proposed framework utilizes high-throughput toxicity assessments of e-liquids and their aerosols, in which the device-to-device variability is minimized, and a systems-level investigation of the cellular mechanisms of toxicity is an integral part. An analytical chemistry investigation is also included as a part of the framework to provide accurate and reliable chemistry data solidifying the toxicological assessment. In its simplest form, the framework comprises of three main layers: (1) high-throughput toxicity screening of e-liquids using primary human cell culture systems; (2) toxicity-related mechanistic assessment of selected e-liquids, and (3) toxicity-related mechanistic assessment of their aerosols using organotypic air–liquid interface airway culture systems. A systems toxicology assessment approach is leveraged to enable in-depth analyses of the toxicity-related cellular mechanisms of e-liquids and their aerosols. We present example use cases to demonstrate the suitability of the framework for a robust in vitro assessment of e-liquids and their aerosols.
BackgroundOnly a few exposure systems are presently available that enable cigarette smoke exposure of living cells at the air–liquid interface, of which one of the most versatile is the Vitrocell® system (Vitrocell® Systems GmbH). To assess its performance and optimize the exposure conditions, we characterized a Vitrocell® 24/48 system connected to a 30-port carousel smoking machine. The Vitrocell® 24/48 system allows for simultaneous exposure of 48 cell culture inserts using dilution airflow rates of 0–3.0 L/min and exposes six inserts per dilution. These flow rates represent cigarette smoke concentrations of 7–100%.ResultsBy characterizing the exposure inside the Vitrocell® 24/48, we verified that (I) the cigarette smoke aerosol distribution is uniform across all inserts, (II) the utility of Vitrocell® crystal quartz microbalances for determining the online deposition of particle mass on the inserts, and (III) the amount of particles deposited per surface area and the amounts of trapped carbonyls and nicotine were concentration dependent. At a fixed dilution airflow of 0.5 L/min, the results showed a coefficient of variation of 12.2% between inserts of the Vitrocell® 24/48 module, excluding variations caused by different runs. Although nicotine and carbonyl concentrations were linear over the tested dilution range, particle mass deposition increased nonlinearly. The observed effect on cell viability was well-correlated with increasing concentration of cigarette smoke.ConclusionsOverall, the obtained results highlight the suitability of the Vitrocell® 24/48 system to assess the effect of cigarette smoke on cells under air–liquid interface exposure conditions, which is closely related to the conditions occurring in human airways.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.