This study compared the effects of two mechanical surface preparation techniques, air abrasion and Nd:YAG laser, with the use of two adhesive systems, self-etch and etch and rinse, on the repair bond strengths of an indirect composite resin. One hundred fifty cylindrical samples of an indirect composite resin were prepared and randomly divided into six groups (n = 25). In groups 1-3, the composite resin surfaces were respectively prepared as follows: no roughening, roughening by air abrasion, and roughening by Nd:YAG laser, followed by application of an etch-and-rinse adhesive. In groups 4-6, the preparation techniques were respectively the same as those in groups 1-3, followed by application of a self-etch adhesive. Subsequently, a direct composite resin was added and repair bond strengths were measured. Data were analyzed with two-way ANOVA and post hoc Tukey's test. Mean bond strength value was significant based on the preparation technique (P < 0.001), i.e., in air abrasion and Nd:YAG laser groups, bond strengths were significantly higher compared to no-preparation groups (P < 0.0005). There were significant differences in bond strength values between air abrasion and Nd:YAG laser groups, with significantly higher values in air abrasion groups (P < 0.0005). However, there were no significant differences in bond strength values between the adhesive systems. Furthermore, the cumulative effects of the adhesive system and the surface preparation technique were not significant. Surface preparation of the indirect composite resin with air abrasion and Nd:YAG laser resulted in a significant increase in the repair bond strength, with air abrasion being more effective. There were no significant differences in bond strength between the two adhesives.
Success in sandwich technique procedures can be achieved through an acceptable bond between the materials. The aim of this study was to compare the effect of 35% phosphoric acid and Er,Cr:YSGG laser on shear bond strength of conventional glass-ionomer cement (GIC) and resin-modified glass-ionomer cement (RMGIC) to composite resin in sandwich technique. Sixty-six specimens were prepared from each type of glass-ionomer cements and divided into three treatment groups as follows: without pretreatment, acid etching by 35% phosphoric acid for 15 s, and 1-W Er,Cr:YSGG laser treatment for 15 s with a 600-μm-diameter tip aligned perpendicular to the target area at a distance of 1 mm from the surface. Energy density of laser irradiation was 17.7 J/cm(2). Two specimens in each group were prepared for evaluation under a scanning electron microscope (SEM) after surface treatment and the remainder underwent bonding procedure with a bonding agent and composite resin. Then the shear bond strength was measured at a crosshead speed of 0.5 mm/min. Two-factor analysis of variance and post-hoc Tukey test showed that the cement type, surface treatment method, and the interaction of these two factors significantly affect the shear bond strength between glass-ionomer cements and composite resin (p < 0.05). Surface treatment with phosphoric acid or Er,Cr:YSGG laser increased the shear bond strength of GIC to composite resin; however, in RMGIC only laser etching resulted in significantly higher bond strength. These findings were supported by SEM results. The fracture mode was evaluated under a stereomicroscope at ×20.
Horizontal pins alone, or with flowable composite, have no effect on the fracture resistance of endodontically-treated maxillary premolars restored with resin composite. SUMMARYMany endodontically-treated teeth require quick, simple, low-cost restorations. This study evaluated the effect of horizontal pins and flowable composites on the fracture resistance of endodontically-treated maxillary premolars directly restored with resin composite.In this in vitro study, 64 intact human maxillary premolars, extracted for orthodontic reasons, were randomly divided into four groups of 16.Standard access cavities were prepared in such a way that the buccal cusp had a buccolingual thickness of 3 mm measured at the height of contour. The palatal cusp was reduced to 1.5 mm coronal to CEJ. The specimens were prepared as follows:Group 1: resin composite restoration without horizontal self-threading pins or flowable composite (control group).Group 2: resin composite restoration without horizontal self-threading pins but with a 2 mm thickness of the flowable composite. Subsequent to thermocycling, all specimens were loaded to failure. The data were analyzed using a two-factor ANOVA test (α=0.05).The maximum mean of fracture resistance was in Group 1 (632.86 ± 119.46 N), and the minimum value was related to Group 3 (533.49 ± 168.07 N). There was not a statistically significant difference between the groups (p>0.05).Conclusion: Neither horizontal pin placement nor flowable composite had a significant effect on increasing the fracture resistance of endodontically-treated maxillary premolars restored with composite.
Aim The aim of the present study was to evaluate the effect of the use of composite fibers (glass fiber and polyethylene fiber) at the gingival third of mesio-occlusodistal (MOD) cavities on the fracture resistance of endodontically treated premolars. Materials and methods A total of 45 extracted premolars underwent endodontic treatment. MOD cavities, 2.5 ± 0.2 mm thick at the buccal and lingual heights of contour, were prepared, with the gingival cavosurface margin 1.5 mm coronal to the cementoenamel junction. Then the teeth were randomly divided into three groups. In group 1, the cavities were restored with Z250 composite resin without the use of any fibers. In groups 2 and 3, the teeth were restored in the same manner as that in group 1 after placement of glass fiber and polyethylene fiber at the gingival third of the cavities, respectively. Subsequent to thermocycling, fracture resistance of the specimens was measured in Newton (N). Statistical analysis Data were analyzed with one-way ANOVA and a post hoc Tukey test at a significance level of p < 0.05. Results There were significant differences in the means of fracture resistance values between the three groups (p = 0.001). Statistically significant differences were observed in the fracture resistance between group 2 and groups 1 and 3 (p < 0.05). However, the differences between groups 1 and 3 were not significant (p = 0.25). Conclusion The type of fiber influenced the fracture resistance of endodontically treated human premolars. Clinical significance Using glass and/or polyethylene fibers in the gingival third of composite restorations leads to different results in fracture resistance of endodontically treated maxillary premolars. How to cite this article Oskoee PA, Chaharom MEE, Kimyai S, Oskoee JS, Varasteh S. Effect of Two Types of Composite Fibers on Fracture Resistance of Endodontically Treated Maxillary Premolars: An in vitro Study. J Contemp Dent Pract 2011;12(1):30-34.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.