The generation of Mn4+ in α-Al2O3:Mn3+ by soft X-ray exposure is demonstrated with a large dynamic range of the X-ray generated Mn4+ luminescence signal, indicating the potential use of α-Al2O3:Mn3+...
Cars of a variety of brands are usually parked at a fixed but increasing distance in the periphery of nuclear installations. Herein we focus on the potential use of car windscreens for post-accident dose reconstruction from unplanned nuclear events and natural disasters, also in regard to unexpected events arising during large-scale use of radioactive and nuclear materials. The situation requires identification of analytical techniques that could both readily and reliably be used to assess absorbed dose, sufficient to prompt remedial action where necessary. Samples from three widely used car brands—Honda, Toyota and Proton—are studied in respect of their thermoluminescence (TL) yield. Key TL dosimetric features in the gamma-ray dose range of 1–100 Gy are examined. An ERESCO model 200 MF4-RW X-ray machine has also been used for energy response studies; a Harshaw 3500 TLD reader equipped with WinREMS software was used for the luminescence measurements. All brands exhibit linearity of TL yield versus dose, the samples from Honda showing the greatest response followed by that of the Toyota and Proton brands. The marked energy dependence reflects the effect of the strongly Z-dependent photoelectric effect. Signal fading was investigated over a period of 28 days, the Toyota and Proton brand windshield glass showing a relatively low loss at 52.1% and 52.6% respectively compared to a 56.7% loss for that of the Honda samples. This work forms the first such demonstration of the potential of car windshield glass as a retrospective accident dosimeter.
Accidents resulting in widespread dispersal of radioactive materials have given rise to a need for materials that are convenient in allowing individual dose assessment. The present study examines natural Dead Sea salt adopted as a model thermoluminescence dosimetry system. Samples were prepared in two different forms, loose-raw and loose-ground, subsequently exposed to 60 Co gamma-rays, delivering doses in the range 2-10 Gy. Key thermoluminescence (TL) properties were examined, including glow curves, dose response, sensitivity, reproducibility and fading. Glow curves shapes were found to be independent of given dose, prominent TL peaks for the raw and ground samples appearing in the temperature ranges 361-385 ºC and 366-401 ºC, respectively. The deconvolution of glow curves has been undertaken using GlowFit, resulting in ten overlapping first-order kinetic glow peaks. For both sample forms, the integrated TL yield displays linearity of response with dose, the loose-raw salt showing some 2.5 × the sensitivity of the ground salt. The samples showed similar degrees of fading, with respective residual signals 28 days post-irradiation of 66% and 62% for the ground and raw forms respectively; conversely, confronted by light-induced fading the respective signal losses were 62% and 80%. The effective atomic number of the Dead Sea salt of 16.3 is comparable to that of TLD-200 (Z eff 16.3), suitable as an environmental radiation monitor in accident situations but requiring careful calibration in the reconstruction of soft tissue dose (soft tissue Z eff 7.2). Sample luminescence studies were carried out via Raman and Photoluminescence spectroscopy as well as X-ray diffraction, ionizing radiation dependent variation in lattice structure being found to influence TL response.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.