In this proof-of-concept study we combine two optical techniques to enable assessment of structure and composition of human skin in vivo: Pulsed photothermal radiometry (PPTR), which involves measurements of transient dynamics in mid-infrared emission from sample surface after exposure to a light pulse, and diffuse reflectance spectroscopy (DRS) in visible part of the spectrum. The analysis involves simultaneous fitting of measured PPTR signals and DRS with corresponding predictions of a Monte Carlo model of light-tissue interaction. By using a four-layer optical model of skin we obtain a good match between the experimental and model data when scattering properties of the epidermis and dermis are also optimized on an individual basis. The assessed parameter values correlate well with literature data and demonstrate the expected trends in controlled tests involving temporary obstruction of peripheral blood circulation using a pressure cuff, and acute as well as seasonal sun tanning.
We are combining two optical techniques, pulsed photothermal radiometry (PPTR) and diffuse reflectance spectroscopy (DRS), for noninvasive assessment of the structure and composition of human skin in vivo. The analysis involves simultaneous multidimensional fitting of the measured PPTR signals and DRS spectra with predictions of a numerical model of light transport (Monte Carlo) in a four-layer model optical model of human skin, accounting for the epidermis, papillary and reticular dermis, and subcutis. The assessed epidermal thickness values were tested by coregistration with a multiphoton microscope, which provides vertical sectioning capability based on two-photon excited fluorescence and second-harmonic generation in selected skin components. The comparison shows that these values correspond well to the maximal epidermal thicknesses measured in the multiphoton microscopy images, the rete ridges.
Monitoring core body temperature (Tc) during training and competitions, especially in a hot environment, can help enhance an athlete’s performance, as well as lower the risk for heat stroke. Accordingly, a noninvasive sensor that allows reliable monitoring of Tc would be highly beneficial in this context. One such novel non-invasive sensor was recently introduced onto the market (CORE, greenTEG, Rümlang, Switzerland), but, to our knowledge, a validation study of this device has not yet been reported. Therefore, the purpose of this study was to evaluate the validity and reliability of the CORE sensor. In Study I, 12 males were subjected to a low-to-moderate heat load by performing, on two separate occasions several days apart, two identical 60-min bouts of steady-state cycling in the laboratory at 19 °C and 30% relative humidity. In Study II, 13 males were subjected to moderate-to-high heat load by performing 90 min of cycling in the laboratory at 31 °C and 39% relative humidity. In both cases the core body temperatures indicated by the CORE sensor were compared to the corresponding values obtained using a rectal sensor (Trec). The first major finding was that the reliability of the CORE sensor is acceptable, since the mean bias between the two identical trials of exercise (0.02 °C) was not statistically significant. However, under both levels of heat load, the body temperature indicated by the CORE sensor did not agree well with Trec, with approximately 50% of all paired measurements differing by more than the predefined threshold for validity of ≤ 0.3 °C. In conclusion, the results obtained do not support the manufacturer’s claim that the CORE sensor provides a valid measure of core body temperature.
The purpose of this double-blinded, crossover randomized and counterbalanced study was to compare the effects of ingesting a tepid commercially available carbohydrate-mentholcontaining sports drink (menthol) and an isocaloric carbohydrate-containing sports drink (placebo) on thermal perception and cycling endurance capacity "in a simulated home virtual cycling environment". It was hypothesized that the addition of menthol would improve indicators of thermal perception and improve endurance exercise capacity. Twelve healthy, endurance-trained males (age 29 ± 5 years, height 181 ± 6 cm, body mass 79 ± 2 kg and V ̇O2 max 57.3 ± 6.4 mL kg −1 min −1 ) completed two experimental trials on a stationary bicycle without external air flow. Each trial consisted of (1) cycling for 60 min at 90% of the first ventilatory threshold while receiving a fixed amount of menthol or placebo every 10 min followed immediately by (2) cycling until volitional exhaustion (TTE) at 105% of the intensity corresponding to the respiratory compensation point. TTE did not differ between both conditions (541 ± 177 and 566 ± 150 s for menthol and placebo; p > 0.05) and neither did ratings of perceived thermal comfort or thermal sensation (p > 0.05). Also, the rectal temperature at the end of TTE was comparable between menthol and placebo trials (38.7 ± 0.2°C and 38.7 ± 0.3°C, respectively; p > 0.05). The present results demonstrate that the addition of menthol to commercially available sports drink does not improve thermal comfort or endurance exercise capacity during ∼65 min of intense virtual cycling.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.