Optical coherence tomography (OCT) in the spectral domain is demonstrated simultaneously at two wavelength bands centered at 800 nm and 1250 nm. A novel commercial supercontinuum laser is applied as a single low coherence broadband light source. The emission spectrum of the source is shaped by optical and spatial filtering in order to achieve an adequate double peak spectrum containing the wavelength bands 700 - 900 nm and 1100 - 1400 nm for dual-band OCT imaging and thus reducing the radiation exposure of the sample. Each wavelength band is analyzed with an individual spectrometer at an A-scan rate of about 12 kHz which enables real-time imaging for the examination of moving samples. A common path optical setup optimized for both spectral regions with a separate single fiber-based scanning unit was realized which facilitates flexible handling and easy access to the measurement area. The free-space axial resolutions were measured to be less than 4.5 microm and 7 microm at 800 nm and 1250 nm, respectively. Three-dimensional imaging ten times faster than previously reported with a signal-to-noise-ratio of above 90 dB is achieved simultaneously in both wavelength bands. Spectral domain dual-band OCT combines real-time imaging with high resolution at 800 nm and enhanced penetration depth at 1250 nm and therefore provides a well suited tool for in vivo vasodynamic measurements. Further, spatially resolved spectral features of the sample are obtained by means of comparing the backscattering properties at two different wavelength bands. The ability of dual-band OCT to enhance tissue contrast and the sensitivity of this imaging modality to wavelength-dependent sample birefringence is demonstrated.
In acute lung injury (ALI), pressure support ventilation (PSV) may improve oxygenation compared with pressure-controlled ventilation (PCV), and benefit from random variation of pressure support (noisy PSV). We investigated the effects of PCV, PSV, and noisy PSV on gas exchange as well as the distribution of lung aeration and perfusion in 12 pigs with ALI induced by saline lung lavage in supine position. After injury, animals were mechanically ventilated with PCV, PSV, and noisy PSV for 1 h/mode in random sequence. The driving pressure was set to a mean tidal volume of 6 ml/kg and positive end-expiratory pressure to 8 cmH₂O in all modes. Functional variables were measured, and the distribution of lung aeration was determined by static and dynamic computed tomography (CT), whereas the distribution of pulmonary blood flow (PBF) was determined by intravenously administered fluorescent microspheres. PSV and noisy PSV improved oxygenation and reduced venous admixture compared with PCV. Mechanical ventilation with PSV and noisy PSV did not decrease nonaerated areas but led to a redistribution of PBF from dorsal to ventral lung regions and reduced tidal reaeration and hyperinflation compared with PCV. Noisy PSV further improved oxygenation and redistributed PBF from caudal to cranial lung regions compared with conventional PSV. We conclude that assisted ventilation with PSV and noisy PSV improves oxygenation compared with PCV through redistribution of PBF from dependent to nondependent zones without lung recruitment. Random variation of pressure support further redistributes PBF and improves oxygenation compared with conventional PSV.
IntroductionThere is an increasing interest in biphasic positive airway pressure with spontaneous breathing (BIPAP+SBmean), which is a combination of time-cycled controlled breaths at two levels of continuous positive airway pressure (BIPAP+SBcontrolled) and non-assisted spontaneous breathing (BIPAP+SBspont), in the early phase of acute lung injury (ALI). However, pressure support ventilation (PSV) remains the most commonly used mode of assisted ventilation. To date, the effects of BIPAP+SBmean and PSV on regional lung aeration and ventilation during ALI are only poorly defined.MethodsIn 10 anesthetized juvenile pigs, ALI was induced by surfactant depletion. BIPAP+SBmean and PSV were performed in a random sequence (1 h each) at comparable mean airway pressures and minute volumes. Gas exchange, hemodynamics, and inspiratory effort were determined and dynamic computed tomography scans obtained. Aeration and ventilation were calculated in four zones along the ventral-dorsal axis at lung apex, hilum and base.ResultsCompared to PSV, BIPAP+SBmean resulted in: 1) lower mean tidal volume, comparable oxygenation and hemodynamics, and increased PaCO2 and inspiratory effort; 2) less nonaerated areas at end-expiration; 3) decreased tidal hyperaeration and re-aeration; 4) similar distributions of ventilation. During BIPAP+SBmean: i) BIPAP+SBspont had lower tidal volumes and higher rates than BIPAP+SBcontrolled; ii) BIPAP+SBspont and BIPAP+SBcontrolled had similar distributions of ventilation and aeration; iii) BIPAP+SBcontrolled resulted in increased tidal re-aeration and hyperareation, compared to PSV. BIPAP+SBspont showed an opposite pattern.ConclusionsIn this model of ALI, the reduction of tidal re-aeration and hyperaeration during BIPAP+SBmean compared to PSV is not due to decreased nonaerated areas at end-expiration or different distribution of ventilation, but to lower tidal volumes during BIPAP+SBspont. The ratio between spontaneous to controlled breaths seems to play a pivotal role in reducing tidal re-aeration and hyperaeration during BIPAP+SBmean.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.