This work describes the fabrication and evaluation of a poly(dimethyl)siloxane (PDMS)-based device that enables the discrete injection of a sample plug from a continuous-flow stream into a microchannel for subsequent analysis by electrophoresis. Devices were fabricated by aligning valving and flow channel layers followed by plasma sealing the combined layers onto a glass plate that contained fittings for the introduction of liquid sample and nitrogen gas. The design incorporates a reduced-volume pneumatic valve that actuates (on the order of hundreds of milliseconds) to allow analyte from a continuously flowing sampling channel to be injected into a separation channel for electrophoresis. The injector design was optimized to include a pushback channel to flush away stagnant sample associated with the injector dead volume. The effect of the valve actuation time, the pushback voltage, and the sampling stream flow rate on the performance of the device was characterized. Using the optimized design and an injection frequency of 0.64 Hz showed that the injection process is reproducible (RSD of 1.77%, n = 15). Concentration change experiments using fluorescein as the analyte showed that the device could achieve a lag time as small as 14 s. Finally, to demonstrate the potential uses of this device, the microchip was coupled to a microdialysis probe to monitor a concentration change and sample a fluorescein dye mixture.
Here, we show that an array of endothelial cells, addressable by an underlying microfluidic network of channels containing red blood cells, can be employed as an in vitro model of in vivo circulation to monitor cellular communication between different cell types in the drug discovery process.
Nitric oxide (NO) is a biologically important short-lived reactive species that has been shown to be involved in a large number of physiological processes. The production of NO is substantially increased in immune and other cell types through the upregulation of inducible nitric oxide synthase (iNOS) caused by exposure to stimulating agents such as lipopolysaccharide (LPS). NO production in cells is most frequently measured via fluorescence microscopy using diaminofluorescein-based probes. Capillary electrophoresis with laser-induced fluorescence detection has been used previously to separate and quantitate the fluorescence derivatives of NO from potential interferences in single neurons. In this paper, microchip electrophoresis (ME) coupled to laser-induced fluorescence (LIF) detection is evaluated as a method for measurement of the NO production by Jurkat cells under control and stimulating conditions. ME is ideal for such analyses due to its fast and efficient separations, low volume requirements, and ultimate compatibility with single cell chemical cytometry systems. In these studies, 4-amino-5-methylamino-2 0 ,7 0 -difluorofluorescein diacetate (DAF-FM DA) was employed for the detection of NO, and 6-carboxyfluorescein diacetate (6-CFDA) was employed as an internal standard. Jurkat cells were stimulated using lipopolysaccharide (LPS) to produce NO, and bulk cell analysis was accomplished using ME-LIF. Stimulated cells exhibited an approximately 2.5-fold increase in intracellular NO production compared to the native cells. A NO standard prepared using diethylamine NONOate (DEA/NO) salt was used to construct a calibration curve for quantitation of NO in cell lysate. Using this calibration curve, the average intracellular NO concentrations for LPS-stimulated and native Jurkat cells were calculated to be 1.5 mM and 0.6 mM, respectively.
The combination of microchip electrophoresis (ME) with amperometric detection leads to a number of analytical challenges that are associated with isolating the detector from the high voltages used for the separation. While methods such as end-channel alignment and the use of decouplers have been employed, they have limitations. A less common method has been to utilize an electrically isolated potentiostat. This approach allows placement of the working electrode directly in the separation channel without using a decoupler. This paper explores the use of microchip electrophoresis and electrochemical detection (ME-EC) with an electrically isolated potentiostat for the separation and in-channel detection of several biologically important anions. The separation employed negative polarity voltages and tetradecyltrimethylammonium bromide (TTAB, as a buffer modifier) for the separation of nitrite (NO2-), glutathione (GSH), ascorbic acid (AA), and tyrosine (Tyr). A half-wave potential (E½) shift of approximately negative 500 mV was observed for NO2- and H2O2 standards in the in-channel configuration compared to end channel. Higher separation efficiencies were observed for both NO2- and H2O2 with the in-channel detection configuration. The limits of detection were approximately two-fold lower and the sensitivity was approximately two-fold higher for in-channel detection of nitrite when compared to end-channel. The application of this microfluidic device for the separation and detection of biomarkers related to oxidative stress is described.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.