OBJECTIVEGlucagon delivery in closed-loop control of type 1 diabetes is effective in minimizing hypoglycemia. However, high insulin concentration lowers the hyperglycemic effect of glucagon, and small doses of glucagon in this setting are ineffective. There are no studies clearly defining the relationship between insulin levels, subcutaneous glucagon, and blood glucose.RESEARCH DESIGN AND METHODSUsing a euglycemic clamp technique in 11 subjects with type 1 diabetes, we examined endogenous glucose production (EGP) of glucagon (25, 75, 125, and 175 μg) at three insulin infusion rates (0.016, 0.032, and 0.05 units/kg/h) in a randomized, crossover study. Infused 6,6-dideuterated glucose was measured every 10 min, and EGP was determined using a validated glucoregulatory model. Area under the curve (AUC) for glucose production was the primary outcome, estimated over 60 min.RESULTSAt low insulin levels, EGP rose proportionately with glucagon dose, from 5 ± 68 to 112 ± 152 mg/kg (P = 0.038 linear trend), whereas at high levels, there was no increase in glucose output (19 ± 53 to 26 ± 38 mg/kg, P = NS). Peak glucagon serum levels and AUC correlated well with dose (r2 = 0.63, P < 0.001), as did insulin levels with insulin infusion rates (r2 = 0.59, P < 0.001).CONCLUSIONSEGP increases steeply with glucagon doses between 25 and 175 μg at lower insulin infusion rates. However, high insulin infusion rates prevent these doses of glucagon from significantly increasing glucose output and may reduce glucagon effectiveness in preventing hypoglycemia when used in the artificial pancreas.
Automated control of blood glucose in patients with type 1 diabetes has not yet been fully implemented. The aim of this study was to design and clinically evaluate a system that integrates a control algorithm with off-the-shelf subcutaneous sensors and pumps to automate the delivery of the hormones glucagon and insulin in response to continuous glucose sensor measurements. The automated component of the system runs an adaptive proportional derivative control algorithm which determines hormone delivery rates based on the sensed glucose measurements and the meal announcements by the patient. We provide details about the system design and the control algorithm, which incorporates both a fading memory proportional derivative controller (FMPD) and an adaptive system for estimating changing sensitivity to insulin based on a glucoregulatory model of insulin action. For an inpatient study carried out in eight subjects using Dexcom SEVEN PLUS sensors, pre-study HbA1c averaged 7.6, which translates to an estimated average glucose of 171 mg/dL. In contrast, during use of the automated system, after initial stabilization, glucose averaged 145 mg/dL and subjects were kept within the euglycemic range (between 70 and 180 mg/dL) for 73.1% of the time, indicating improved glycemic control. A further study on five additional subjects in which we used a newer and more reliable glucose sensor (Dexcom G4 PLATINUM) and made improvements to the insulin and glucagon pump communication system resulted in elimination of hypoglycemic events. For this G4 study, the system was able to maintain subjects’ glucose levels within the near-euglycemic range for 71.6% of the study duration and the mean venous glucose level was 151 mg/dL.
To be effective in type 1 diabetes, algorithms must be able to limit hyperglycemic excursions resulting from medical and emotional stress. We tested an algorithm that estimates insulin sensitivity at regular intervals and continually adjusts gain factors of a fading memory proportional-derivative (FMPD) algorithm. In order to assess whether the algorithm could appropriately adapt and limit the degree of hyperglycemia, we administered oral hydrocortisone repeatedly to create insulin resistance. We compared this indirect adaptive proportionalderivative (APD) algorithm to the FMPD algorithm, which used fixed gain parameters. Each subject with type 1 diabetes (n = 14) was studied on two occasions, each for 33 h.The APD algorithm consistently identified a fall in insulin sensitivity after hydrocortisone. The gain factors and insulin infusion rates were appropriately increased, leading to satisfactory glycemic control after adaptation (premeal glucose on day 2, 148 ± 6 mg/dl). After sufficient time was allowed for adaptation, the late postprandial glucose increment was significantly lower than when measured shortly after the onset of the steroid effect. In addition, during the controlled comparison, glycemia was significantly lower with the APD algorithm than with the FMPD algorithm. No increase in hypoglycemic frequency was found in the APD-only arm.An afferent system of duplicate amperometric sensors demonstrated a high degree of accuracy; the mean absolute relative difference of the sensor used to control the algorithm was 9.6 ± 0.5%. We conclude that an adaptive algorithm that frequently estimates insulin sensitivity and adjusts gain factors is capable of minimizing corticosteroid-induced stress hyperglycemia.
A soy-based formula containing 2.45 g protein/100 kcal and approximately 640 mumol of total sulfur containing amino acids/100 kcal adequately meets the protein needs of term infants from 2 to 112 days of age.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.