The influence of variables that might affect the accuracy of pulse oximetry (SpO 2 ) recordings in critically ill patients is not well established. We sought to describe the relationship between paired SpO 2 /SaO 2 (oxygen saturation via arterial blood gas analysis) in adult intensive care unit (ICU) patients and to describe the diagnostic performance of SpO 2 in detecting low SaO 2 and PaO 2 . A paired SpO 2 /SaO 2 measurement was obtained from 404 adults in ICU. Measurements were used to calculate bias, precision, and limits of agreement. Associations between bias and variables including vasopressor and inotrope use, capillary refill time, hand temperature, pulse pressure, body temperature, oximeter model, and skin colour were estimated. There was no overall statistically significant bias in paired SpO 2 /SaO 2 measurements; observed limits of agreement were +/-4.4%. However, body temperature, oximeter model, and skin colour, were statistically significantly associated with the degree of bias. SpO 2 <89% had a sensitivity of 3/7 (42.9%; 95% confidence intervals, CI, 9.9% to 81.6%) and a specificity of 344/384 (89.6%; 95% CI 86.1% to 92.5%) for detecting SaO 2 <89%. The absence of statistically significant bias in paired SpO 2 /SaO 2 in adult ICU patients provides support for the use of pulse oximetry to titrate oxygen therapy. However, SpO 2 recordings alone should be used cautiously when SaO 2 recordings of 4.4% higher or lower than the observed SpO 2 would be of concern. A range of variables relevant to the critically ill had little or no effect on bias.
Extracorporeal membrane oxygenation (ECMO) is a support modality used within the pediatric cardiac ICU population as a bridge to recovery or decision in the setting of acute myocardial decompensation, support for combined cardiopulmonary failure or in the setting of refractory cardiopulmonary arrest. Patients with univentricular physiology are at particular risk for decompensation requiring ECMO support. This review will focus upon current evidence and techniques for ECMO support of single ventricle patients who have undergone a stage II bidirectional Glenn procedure or the stage III Fontan procedure.
In extracorporeal life support (ECLS), there are two main types of oxygenators in clinical use for neonates: polymethylpentene (PMP) hollow fiber and polypropylene (PP) hollow fiber. A retrospective study was performed on neonates (n = 44) who had undergone ECLS for noncardiac indications from 2009 to 2015. Between the two groups (PMP n = 21, PP n = 23), the PP oxygenators failed 91% of the time, whereas the PMP oxygenators failed 43% of the time (p < 0.05). Analysis suggests PMP oxygenators are less prone to failure than PP oxygenators, and they require fewer number of oxygenator changes during a neonatal ECLS.
Iron deficiency anemia has been associated with a secondary and potentially reversible cardiomyopathy. The pathophysiologic paradigm has been that the hematologic disease begets cardiac dysfunction. There may be, however, a point at which myocardial injury is irreversible in susceptible individuals. We present the case of a 4-year-old, developmentally normal, child who presented with iron deficiency anemia and a dilated cardiomyopathy with congestive heart failure. Despite appropriate correction of the anemia, the patient developed decompensated heart failure requiring milrinone therapy and eventual heart transplantation. This report will alert clinicians to the potential for irreversible adverse cardiac remodeling and the importance of close pediatric cardiology consultation and serial assessment in order to implement appropriate heart failure therapy.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.