BackgroundNormal coronary flow velocity reserve (CFVR) (≥ 2) obtained in the left anterior descending coronary artery (LAD) from transthoracic echocardiography is associated with a good prognosis, but there is no study correlating CFVR with submaximal target heart rate (HR).ObjectiveTo evaluate the prognostic value of CFVR obtained in the LAD of patients with preserved (>50%) left ventricular ejection fraction (LVEF) who completed a dobutamine stress echocardiography (DSE), considering target HR.MethodsProspective study of patients with preserved LVEF and CFVR obtained in the LAD who completed DSE. In Group I (GI = 31), normal CFVR was obtained before achieving target HR, and, in Group II (GII = 28), after that. Group III (G III=24) reached target HR, but CFVR was abnormal. Death, acute coronary insufficiency, coronary intervention, coronary angiography without further intervention, and hospitalization were considered events.ResultsIn 28 ± 4 months, there were 18 (21.6%) events: 6% (2/31) in GI, 18% (5/28) in GII, and 46% (11/24) in GIII. There were 4 (4.8%) deaths, 6 (7.2%) coronary interventions and 8 (9.6%) coronary angiographies without further intervention. In event-free survival by regression analysis, GIII had more events than GI (p < 0.001) and GII (p < 0.045), with no difference between GI and GII (p = 0.160). After adjustment, the only difference was between GIII and GI (p = 0.012).ConclusionIn patients with preserved LVEF and who completed their DSE, normal CFVR obtained before achieving target HR was associated with better prognosis.
SummaryBackground: The patent internal thoracic artery graft (ITAG) usually has a diastolic fraction (DF) > 50% of the flow. The functional assessment can be evaluated by the coronary reserve index (CRI).
Background A coronary flow velocity reserve (CFVR) ≥ 2 is adequate to infer a favorable prognosis or the absence of significant coronary artery disease. Objective To identify parameters which are relevant to obtain CFVR (adequate or inadequate) in the left anterior descending coronary artery (LAD) during dobutamine stress echocardiography (DSE). Methods 100 patients referred for detection of myocardial ischemia by DSE were evaluated; they were instructed to discontinue the use of β-blockers 72 hours prior to the test. CFVR was calculated as a ratio of the diastolic peak velocity (cm/s) (DPV) on DSE (DPV-DSE) to baseline DPV at rest (DPV-Rest). In group I, CFVR was < 2 and, in group II, CFVR was ≥ 2. The Fisher's exact test and Student's t test were used for the statistical analyses. P values < 0.05 were considered statistically significant. Results At rest, the time (in seconds) to obtain Doppler in LAD in groups I and II was not different (53±31 vs. 45±32; p=0.23). During DSE, LAD was recorded in 92 patients. Group I patients were older (65.9±9.3 vs. 61.2±10.8 years; p=0.04), had lower ejection fraction (61±10 vs. 66±6%; p=0.005), higher DPV-Rest (36.81±08 vs. 25.63 ± 06cm/s; p<0.0001) and lower CFVR (1.67 ± 0.24 vs. 2.53 ± 0.57; p<0.0001), but no difference was observed regarding DPVDSE (61.40±16 vs. 64.23±16cm/s; p=0.42). β-blocker discontinuation was associated with a 4-fold higher chance of a CFVR < 2 (OR= 4; 95% CI [1.171-13.63], p=0.027). Conclusion DPV-Rest was the main parameter to determine an adequate CFVR. β-blocker discontinuation was significantly associated with inadequate CFVR. The high feasibility and the time to record the LAD corroborate the use of this methodology.
BackgroundCardiovascular disease is a leading cause of death in the world and in Brazil. Myocardial scintigraphy is an important noninvasive method for detecting ischemia in symptomatic patients, but its use in asymptomatic ones or those with atypical symptoms is yet to be defined.ObjectiveTo verify the presence of major cardiac events in asymptomatic patients or those with atypical symptoms (atypical chest pain or dyspnea) that underwent myocardial scintigraphy (MS), over a period of 8 years. Secondary objectives were to identify cardiac risk factors associated with myocardial scintigraphy abnormalities and possible predictors for major cardiac events in this group.MethodsThis was a retrospective, observational study using the medical records of 892 patients that underwent myocardial scintigraphy between 2005 and 2011 and who were followed until 2013 for assessment of major cardiac events and risk factors associated with myocardial scintigraphy abnormalities. Statistical analysis was performed by Fisher’s exact test, logistic regression and Kaplan-Meyer survival curves, with statistical significance being set at p ≤ 0.05.ResultsOf the total sample, 52.1% were men, 86.9% were hypertensive, 72.4% had hyperlipidemia, 33.6% were diabetic, and 12.2% were smokers; 44.5% had known coronary artery disease; and 70% had high Framingham score, 21.8% had moderate and 8% had low risk. Of the myocardial scintigraphies, 58.6% were normal, 26.1% suggestive of fibrosis and 15.3% suggestive of ischemia. At evolution, 13 patients (1.5%) had non-fatal myocardial infarction and six individuals (0.7%) died. The group with normal myocardial scintigraphy showed longer period of time free of major cardiac events, non-fatal myocardial infarction (p = 0.036) and death. Fibrosis in the myocardial scintigraphy determined a 2.4-fold increased risk of non-fatal myocardial infarction and five-fold higher risk of death (odds ratio: 2.4 and 5.7, respectively; p = 0.043).ConclusionThe occurrence of major cardiac events in 8 years was small. Patients with fibrosis at MS had more major events, whereas patients with normal MS result had fewer major cardiac events, with higher survival.
Fundamento: Durante o ecocardiograma sob estresse com dobutamina, podem ocorrer efeitos adversos e exames inconclusivos. Objetivo: Avaliar em uma grande população geral a segurança e a exequibilidade do ecocardiograma sob estresse com dobutamina. Métodos: Estudo de 10.006 ecocardiogramas sob estresse com dobutamina realizados no período de julho de 1996 a setembro de 2007. A dobutamina foi administrada em quatro estágios (10, 20, 30 e 40 μcg.kg-1.min-1) para pesquisa de isquemia miocárdica e iniciada com 5 μcg.kg- ¹.min-1 apenas na análise de viabilidade miocárdica. A atropina foi iniciada conforme os protocolos vigentes. Foram verificados dados clínicos, hemodinâmicos e efeitos adversos associados ao ecocardiograma sob estresse com dobutamina. Resultados: Durante os ecocardiogramas sob estresse com dobutamina, ocorreu angina típica (8,9%), pico hipertensivo (1,7%), ectopias ventriculares isoladas (31%), taquiarritmia supraventricular (1,89%), fibrilação atrial (0,76%) e taquicardia ventricular não sustentada (0,6%). Os efeitos adversos citados foram mais frequentes nos pacientes com ecocardiogramas sob estresse com dobutamina positivos para isquemia. A desaceleração sinusal paradoxal (0,16%) não ocorreu em ecocardiogramas sob estresse com dobutamina positivo. As três complicações graves ocorreram em ecocardiogramas sob estresse com dobutamina positivos para isquemia. Foram dois casos (0,02%) com fibrilação ventricular e um caso de síndrome coronariana aguda (0,01%). Não houve caso de taquicardia ventricular sustentada, ruptura cardíaca, assistolia ou óbito. Comparados aos exames concluídos, nos inconclusivos, os pacientes usaram menos atropina (81,5% versus 49,9%; p< 0,001) e mais betabloqueador (4,7% versus 19%; p< 0,001), apresentando mais pico hipertensivo (1,1% versus 14,2%; p = 0,0001) e taquicardia ventricular não sustentada (0,5% versus 2,2%; p< 0,001). Conclusão: O ecocardiograma sob estresse com dobutamina realizado de forma apropriada é seguro e apresenta elevada exequibilidade.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.