Many patients with incomplete spinal cord injury (iSCI) have impaired gait and balance capacity, which may impact daily functioning. Reduced walking speed and impaired gait stability are considered important underlying factors for reduced daily functioning. With conventional therapy, patients are limited in training gait stability, but this can be trained on a treadmill in a virtual environment, such as with the Gait Real-time Analysis Interactive Lab (GRAIL). Our objective was to evaluate the effect of 6-weeks GRAIL-training on gait and dynamic balance in ambulatory iSCI patients. In addition, the long-term effect was assessed. Fifteen patients with chronic iSCI participated. The GRAIL training consisted of 12 one-hour training sessions during a 6-week period. Patients performed 2 minute walking tests on the GRAIL in a self-paced mode at the 2nd, and 3rd (baseline measurements) and at the 12th training session. Ten patients performed an additional measurement after 6 months. The primary outcome was walking speed. Secondary outcomes were stride length, stride frequency, step width, and balance confidence. In addition, biomechanical gait stability measures based on the position of the center of mass (CoM) or the extrapolated center of mass (XCoM) relative to the center of pressure (CoP) or the base of support (BoS) were derived: dynamic stability margin (DSM), XCoM-CoP distance in anterior-posterior (AP) and medial-lateral (ML) directions, and CoM-CoP inclination angles in AP and ML directions. The effect of GRAIL-training was tested with a one-way repeated measures ANOVA (α = 0.05) and post-hoc paired samples t-tests (α = 0.017). Walking speed was higher after GRAIL training (1.04 m/s) compared to both baseline measurements (0.85 and 0.93 m/s) (p < 0.001). Significant improvements were also found for stride length (p < 0.001) and stability measures in AP direction (XCoM-CoPAP (p < 0.001) and CoM-CoPAP−angle (p < 0.001)). Stride frequency (p = 0.27), step width (p = 0.19), and stability measures DSM (p = 0.06), XCoM-CoPML (p = 0.97), and CoM-CoPML−angle (p = 0.69) did not improve. Balance confidence was increased after GRAIL training (p = 0.001). The effects were remained at 6 months. Increased walking speed, stride length, AP gait stability, and balance confidence suggest that GRAIL-training improves gait and dynamic balance in patients with chronic iSCI. In contrast, stability measures in ML direction did not respond to GRAIL-training.
The aim of this study was to objectively assess and compare gait capacity and gait performance in rehabilitation inpatients with stroke or incomplete spinal cord injury (iSCI) using inertial measurement units (IMUs). We investigated how gait capacity (what someone can do) is related to gait performance (what someone does). Twenty-two inpatients (11 strokes, 11 iSCI) wore ankle positioned IMUs during the daytime to assess gait. Participants completed two circuits to assess gait capacity. These were videotaped to certify the validity of the IMU algorithm. Regression analyses were used to investigate if gait capacity was associated with gait performance (i.e., walking activity and spontaneous gait characteristics beyond therapy time). The ankle positioned IMUs validly assessed the number of steps, walking time, gait speed, and stride length (r ≥ 0.81). The walking activity was strongly (r ≥ 0.76) related to capacity-based gait speed. Maximum spontaneous gait speed and stride length were similar to gait capacity. However, the average spontaneous gait speed was half the capacity-based gait speed. Gait capacity can validly be assessed using IMUs and is strongly related to gait performance in rehabilitation inpatients with neurological disorders. Measuring gait performance with IMUs provides valuable additional information about walking activity and spontaneous gait characteristics to inform about functional recovery.
Background Impaired balance during walking is a common problem in people with incomplete spinal cord injury (iSCI). To improve walking capacity, it is crucial to characterize balance control and how it is affected in this population. The foot placement strategy, a dominant mechanism to maintain balance in the mediolateral (ML) direction during walking, can be affected in people with iSCI due to impaired sensorimotor control. This study aimed to determine if the ML foot placement strategy is impaired in people with iSCI compared to healthy controls. Methods People with iSCI (n = 28) and healthy controls (n = 19) performed a two-minute walk test at a self-paced walking speed on an instrumented treadmill. Healthy controls performed one extra test at a fixed speed set at 50% of their preferred speed. To study the foot placement strategy of a participant, linear regression was used to predict the ML foot placement based on the ML center of mass position and velocity. The accuracy of the foot placement strategy was evaluated by the root mean square error between the predicted and actual foot placements and was referred to as foot placement deviation. Independent t-tests were performed to compare foot placement deviation of people with iSCI versus healthy controls walking at two different walking speeds. Results Foot placement deviation was significantly higher in people with iSCI compared to healthy controls independent of walking speed. Participants with iSCI walking in the self-paced condition exhibited 0.40 cm (51%) and 0.33 cm (38%) higher foot placement deviation compared to healthy controls walking in the self-paced and the fixed-speed 50% condition, respectively. Conclusions Higher foot placement deviation in people with iSCI indicates an impaired ML foot placement strategy in individuals with iSCI compared to healthy controls.
Recovery of the walking function is one of the most common rehabilitation goals of neurological patients. Sufficient and adequate sleep is a prerequisite for recovery or training. To objectively monitor patients’ progress, a combination of different sensors measuring continuously over time is needed. A sensor-based technological platform offers possibilities to monitor gait and sleep. Implementation in clinical practice is of utmost relevance and has scarcely been studied. Therefore, this study examined the feasibility of a sensor-based technological platform within the clinical setting. Participants (12 incomplete spinal cord injury (iSCI), 13 stroke) were asked to wear inertial measurement units (IMUs) around the ankles during daytime and the bed sensor was placed under their mattress for one week. Feasibility was established based on missing data, error cause, and user experience. Percentage of missing measurement days and nights was 14% and 4%, respectively. Main cause of lost measurement days was related to missing IMU sensor data. Participants were not impeded, did not experience any discomfort, and found the sensors easy to use. The sensor-based technological platform is feasible to use within the clinical rehabilitation setting for continuously monitoring gait and sleep of iSCI and stroke patients.
Background Since adequate sleep is essential for optimal inpatient rehabilitation, there is an increased interest in sleep assessment. Unobtrusive, contactless, portable bed sensors show great potential for objective sleep analysis. Objective The aim of this study was to investigate the feasibility of a bed sensor for continuous sleep monitoring overnight in a clinical rehabilitation center. Methods Patients with incomplete spinal cord injury (iSCI) or stroke were monitored overnight for a 1-week period during their in-hospital rehabilitation using the Emfit QS bed sensor. Feasibility was examined based on missing measurement nights, coverage percentages, and missing periods of heart rate (HR) and respiratory rate (RR). Furthermore, descriptive data of sleep-related parameters (nocturnal HR, RR, movement activity, and bed exits) were reported. Results In total, 24 participants (12 iSCI, 12 stroke) were measured. Of the 132 nights, 5 (3.8%) missed sensor data due to Wi-Fi (2), slipping away (1), or unknown (2) errors. Coverage percentages of HR and RR were 97% and 93% for iSCI and 99% and 97% for stroke participants. Two-thirds of the missing HR and RR periods had a short duration of ≤120 seconds. Patients with an iSCI had an average nocturnal HR of 72 (SD 13) beats per minute (bpm), RR of 16 (SD 3) cycles per minute (cpm), and movement activity of 239 (SD 116) activity points, and had 86 reported and 84 recorded bed exits. Patients with a stroke had an average nocturnal HR of 61 (SD 8) bpm, RR of 15 (SD 1) cpm, and movement activity of 136 (SD 49) activity points, and 42 reported and 57 recorded bed exits. Patients with an iSCI had significantly higher nocturnal HR (t18=−2.1, P=.04) and movement activity (t18=−1.2, P=.02) compared to stroke patients. Furthermore, there was a difference between self-reported and recorded bed exits per night in 26% and 38% of the nights for iSCI and stroke patients, respectively. Conclusions It is feasible to implement the bed sensor for continuous sleep monitoring in the clinical rehabilitation setting. This study provides a good foundation for further bed sensor development addressing sleep types and sleep disorders to optimize care for rehabilitants.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.