Since its initial isolation in Uganda in 1937 through the present, West Nile virus (WNV) has become an important cause of human and animal disease worldwide. WNV, an enveloped virus of the genus Flavivirus, is naturally maintained in an enzootic cycle between birds and mosquitoes, with occasional epizootic spillover causing disease in humans and horses. The mosquito vectors for WNV are widely distributed worldwide, and the known geographic range of WNV transmission and disease has continued to increase over the past 77 years. While most human infections with WNV are asymptomatic, severe neurological disease may develop resulting in long-term sequelae or death. Surveillance and preventive measures are an ongoing need to reduce the public health impact of WNV in areas with the potential for transmission.
Imatinib interruption results in rapid progression in most patients with advanced GIST, and cannot be recommended in routine practice unless patient experience significant toxicity
ESBL-producing E. coli is a significant cause of bloodstream infection in hospitalized and nonhospitalized patients in the context of the emergence of CTX-M enzymes. Empirical treatment of sepsis potentially caused by E. coli may need to be reconsidered in areas where such ESBL-producing isolates are present.
Background. Transient elastometry (TE) is accurate for detecting significant liver fibrosis and cirrhosis in hepatitis C virus (HCV)-monoinfected patients. However, this procedure has been insufficiently validated in patients with human immunodeficiency virus (HIV) and HCV coinfection. The purpose of this study was to validate reported cutoff values of TE that discriminate significant liver fibrosis and cirrhosis in HIV-HCV-coinfected subjects.Methods. Liver stiffness measurements were obtained for 169 HIV-HCV-coinfected adult patients who had undergone a liver biopsy or who had received a nonhistologic diagnosis of cirrhosis within 12 months before or after a liver stiffness measurement. Patients had received no prior therapy for HCV infection.Results. TE measurements ranged from 3.6 kPa to 75 kPa. The area under the receiver operating characteristic curve was 0.87 (95% confidence interval, 0.84-0.93) for significant liver fibrosis and 0.95 (95% confidence interval, 0.92-0.99) for cirrhosis. To diagnose significant liver fibrosis, a cutoff value of 7.2 kPa was associated with a positive predictive value of 88% and a negative predictive value of 75%. Thirty-four patients (20%) were misclassified when this cutoff value was used. Thirteen (24%) of 54 patients with liver stiffness values !7.2 kPa had significant liver fibrosis detected by liver biopsy. To diagnose cirrhosis, a cutoff value of 14.6 kPa was associated with a positive predictive value of 86% and a negative predictive value of 94%. Thus, 13 patients (10%) had disease that was misclassified using this cutoff value.Conclusions. We found that the diagnostic accuracy of TE was high for detecting cirrhosis and good for diagnosis of significant liver fibrosis. However, the performance of TE was low for discriminating mild fibrosis from significant liver fibrosis, which might limit the applicability of this technique in clinical practice.
The compliance to clinical practice guidelines and relapse-free survival of sarcoma patients are significantly better when the initial treatment is guided by a pre-therapeutic specialized MDTB.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.