| on behalf of the TiN study groupThis is an open access article under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non-commercial and no modifications or adaptations are made. AbstractBackground: Patients with congenital blood platelet disorders (CPDs) demonstrate a predominantly mucocutaneous bleeding tendency. Repeated bleeds throughout life can have a significant impact on health status-related quality of life (HR-QoL), but few studies have investigated HR-QoL in patients with CPDs. Objectives:To determine HR-QoL in patients with suspected or confirmed CPDs as compared with the general Dutch population and to assess the association between bleeding phenotype and HR-QoL.Methods: Data were derived from the Thrombocytopathy in the Netherlands (TiN) study, a cross-sectional study of individuals suspected for a congenital platelet defect. TiN patients with an increased ISTH Bleeding Assessment Tool (ISTH-BAT) score (>3 in men and > 5 in women) were included for analysis. HR-QoL was assessed with the Short Form (SF)-36 survey. Bleeding symptoms were evaluated with the ISTH-BAT, resulting in a bleeding score. Results:One hundred fifty-six patients were analyzed, of whom 126 (81%) were women. Sixty-two patients (40%) had a confirmed CPD. Compared to the general Dutch population, patients with a suspected or confirmed CPD reported decreased physical functioning, limitations in daily activities due to physical health problems, limitations in social activities, decreased energy levels and fatigue, pain, and lower general health status. HR-QoL was not correlated with the ISTH-BAT score and was similar in patients with a confirmed CPD and those in whom a CPD could not be diagnosed. Conclusion:A bleeding tendency in patients with a suspected or confirmed CPD significantly impacts HR-QoL, independent of a confirmed explanatory diagnosis. K E Y W O R D Sbleeding tendency, congenital blood platelet disorders, health status, quality of life, SF-36 | 101 BLAAUWGEERS Et AL. S U PP O RTI N G I N FO R M ATI O NAdditional supporting information may be found online in the Supporting Information section.
Introduction Standardized bleeding assessment tools (BATs), such as the International Society for Thrombosis and Hemostasis (ISTH)-BAT, are screening instruments used during the diagnostic workup of suspected bleeding disorders. A self-administered ISTH-BAT (self-BAT) would enhance screening and save time during an outpatient clinic visit. Aim This study was aimed to investigate the reliability and feasibility of the self-BAT. Methods The electronic self-BAT was created from the ISTH-BAT and paper-version of self-BAT and optimized by patients and physicians. Patients with a (suspected) congenital platelet defect (CPD), who had previously undergone physician-administered ISTH-BAT assessment, were invited to complete the self-BAT. Optimal self-BAT cut-off values to detect a bleeding tendency, as defined by the ISTH-BAT, were evaluated by receiver operator characteristic (ROC) curve analysis to reach a sensitivity ≥95%. Reliability was tested by assessing sensitivity, specificity, and intraclass correlation (ICC). Feasibility was evaluated on comprehension and length of self-BAT. Results Both versions of the BAT were completed by 156 patients. Optimal cut-off values for self-BAT to define a bleeding tendency were found to be identical to those of the ISTH-BAT. Normal/abnormal scores of the ISTH-BAT and self-BAT were agreed in 88.5% (138/156, 95% confidence interval [CI]: 0.83–0.93) of patients. The sensitivity and specificity of the self-BAT to detect a bleeding tendency were 96.9 and 48.1%, respectively. The ICC was 0.73. Self-BAT questions were graded by 96.8% (151/156) as “very easy,” “easy,” and “satisfactory” and questionnaire length as “exactly right” by 91% (142/156) of patients. Conclusion In patients with a (suspected) CPD, the self-BAT is sufficiently reliable and feasible to detect a bleeding tendency, which supports its use as a screening tool.
Background δ‐storage pool disease (δ‐SPD) is a bleeding disorder characterized by a reduced number of platelet‐dense granules. The diagnosis of δ‐SPD depends on the measurement of platelet ADP content, but this test is time consuming and requires a relatively large blood volume. Flow cytometric analysis of platelet mepacrine uptake is a potential alternative, but this approach lacks validation, which precludes its use in a diagnostic setting. Objectives To evaluate the performance of platelet mepacrine uptake as a diagnostic test for δ‐SPD. Patients/Methods Mepacrine fluorescence was determined with flow cytometry before and after platelet activation in 156 patients with a suspected platelet function disorder and compared with platelet ADP content as a reference test. Performance was analyzed with a receiver operating characteristic (ROC) curve. Results Eleven of 156 patients had δ‐SPD based on platelet ADP content. Mepacrine fluorescence was inferior to platelet ADP content in identifying patients with δ‐SPD, but both mepacrine uptake (area under the ROC curve [AUC] 0.87) and mepacrine release after platelet activation (AUC 0.80) had good discriminative ability. In our tertiary reference center, mepacrine uptake showed high negative predicitive value (97%) with low positive predictive value (35%). Combined with a negative likelihood ratio of 0.1, these data indicate that mepacrine uptake can be used to exclude δ‐SPD in patients with a bleeding tendency. Conclusion Mepacrine fluorescence can be used as a screening tool to exclude δ‐SPD in a large number of patients with a suspected platelet function disorder.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.