The magnitude and clinical significance of Hepatitis C virus (HCV) infection in dialysis patients is controversial and underestimated. This study was conducted in order to evaluate the correlation between HCV replication and antibody response to HCV in dialysis patients. HCV infection in dialysis patients was evaluated over a period of 3 years and compared to HCV infection in Liver Clinic patients. Sera were collected from 310 dialysis patients and tested for anti-HCV and HCV-RNA. In addition, HCV genotype and HCV viral load were determined in HCV-RNA-positive sera. Anti-HCV was detected in 43 (14%) of the dialysis patients. Of these, 37 (86%) were HCV-RNA-positive. Among the 267 HCV-seronegative dialysis patients, 25 (9%) were found to be HCV-RNA-positive in more than one sample during the study. These patients were characterized by low viral load; at least two orders of magnitude lower than in the group of HCV-seropositives. In contrast, in the Liver Clinic patients, HCV-RNA was found exclusively in HCV-seropositive patients. Comparison of the genotype pattern in the two groups did not reveal a difference. Our results suggest that HCV infection in dialysis units may be underestimated due to cases of low viral load, depending on the method of RNA extraction and sensitivity of the test used. Low viral load might contribute to the lack of humoral immune response seen in some dialysis patients.
We describe four patients who developed an encephalopathic syndrome characterized by obtundation or stupor, myoclonic jerks, and asterixis in association with cefuroxime therapy. Three patients had renal failure. These cases suggest that cefuroxime in overdose or in conventional doses in patients with renal failure can cause a reversible encephalopathy. This syndrome may have been unrecognized because it usually occurs in severely ill patients with additional causes for encephalopathy.
Cryptic hepatitis C virus (HCV) infection relates to patients infected chronically with HCV that are seronegative but have HCV-RNA. These patients are not identified by the standard serological tests for HCV, which are based on detection of antibodies to core, NS3 and NS5 antigens. They will, therefore, be wrongly diagnosed as non-infected, and are considered as a potential risk for others. Cryptic HCV infection in dialysis units occurs frequently and, due to medical procedures, is a major factor for contracting the virus when unrecognised. This study was conducted in order to assess the humoral immune responses to E2-antigen in sera of patients infected chronically with HCV. Recombinant E2 protein in enzyme linked immunosorbent assay (ELISA) and Western blot (WB) were used to test the occurrence of anti-E2 antibodies in the sera of patients from the liver clinic and of dialysis patients. The presence of E2 antibodies was found to be correlated with the presence of HCV-RNA and with viral load. Antibodies to the E2 protein could be detected in as many as 30% of the sera from dialysis patients with cryptic HCV infection (HCV-RNA only). The results suggest that detection of anti-E2 antibodies may enhance significantly HCV serological standard testing; especially among patients on dialysis, and that antibodies to envelope E2 protein appear to depend on and correlate with the presence of HCV particles.
Background: Cuffed-tunneled hemodialysis (HD) catheters are recommended as a bridging therapy until peripheral access is available, but their long-term use is controversial. Aim: To evaluate the complications and lifetime of twin-tunneled HD catheters and to identify parameters which could predict their outcome. Methods: 29 chronic HD patients (19 female and 10 male) were inserted with twin hemodialysis catheters (28 Tesio, 1 Schon Duoflow), followed for up to 9 months or until catheter loss, and evaluated for severe catheter-related complications necessitating catheter removal. Since the most common severe complication was catheter-related infection, we retrospectively examined whether parameters such as age, gender, duration of end-stage renal disease, delivered dose of dialysis, nutrition, diabetes and indices of social support correlate with this outcome. Results: Severe catheter infection requiring catheter removal occurred in 11 patients (10 female). Of these infected female patients, 9 were elderly (≧67 years) and in 6 of those, catheter infection was fatal (54% of infected cases). At 9 months, severe catheter infection and related patient death rates were 38 and 21%, respectively. Severe catheter infection was significantly related to less social support (p < 0.005), older age, female gender, lower nPCR (all p < 0.05), and tended to be related to shorter end-stage renal disease duration prior to catheter insertion (p = 0.06). Conclusion: This study demonstrated that twin HD catheters are associated with a high incidence of severe catheter-related infections which was most significantly related to social-support as well as inadequate nutrition, older age and female gender. Therefore, we suggest early removal of the catheter, enhancement of social support and dietary counseling for the elderly and lonely HD patients using this type of catheter.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.