BackgroundFabry disease (FD) is an X-linked recessive hereditary lysosomal storage disorder which results in the accumulation of globotriaosylceramid (Gb3) in tissues of kidney and heart as well as central and peripheral nervous system.Besides prominent renal and cardiac organ involvement, cochlear symptoms like high-frequency hearing loss and tinnitus are frequently found with yet no comprehensive data available in the literature.ObjectiveTo examine hearing loss in patients with FD depending on cardiac and renal function.Material and methodsSingle-center study with 68 FD patients enrolled between 2012 and 2016 at the Department of Oto-Rhino-Laryngology, Plastic, Aesthetic and Reconstructive Head and Neck Surgery of the University of Würzburg. Every subject underwent an oto-rhino-laryngological examination as well as behavioral, electrophysiological and electroacoustical audiological testing. High-frequency thresholds were evaluated by using a modified PTA6 (0.5, 1, 2, 4, 6, 8) and HF-PTA (6, 8 kHz). Renal function was measured by eGFR, cardiac impairment was graduated by NYHA class.ResultsSensorineural hearing loss was detected in 58.8% of the cohort, which occurred typically in sudden episodes and affected especially high frequencies. Hearing loss is asymmetric, beginning unilaterally and affecting the contralateral ear later. Tinnitus was reported by 41.2%. Renal and cardiac impairment influenced the severity of hearing loss (p < 0.05).ConclusionsHigh frequency hearing loss is a common problem in patients with FD. Although not life-threatening, it can seriously reduce quality of life and should be taken into account in diagnosis and therapy. Optimized extensive hearing assessment including higher frequency thresholds should be used.
BackgroundFabry Disease (FD) is an X-linked hereditary lysosomal storage disorder which leads to a multisystemic intralysosomal accumulation of globotriaosylceramid (Gb3). Besides prominent renal and cardiac organ involvement, patients commonly complain about vestibulocochlear symptoms like high-frequency hearing loss, tinnitus and vertigo. However, comprehensive data especially on vertigo remain scarce. The aim of this study was to examine the prevalence and characteristics of vertigo and hearing loss in patients with FD, depending on renal and cardiac parameters and get hints about the site and the pattern of the lesions.MethodsSingle-center study with 57 FD patients. Every patient underwent an oto-rhino-laryngological examination as well as videonystagmography and vestibular evoked myogenic potentials (VEMPs) and audiological measurements using pure tone audiometry and auditory brainstem response audiometry (ABR). Renal function was measured by eGFR, cardiac impairment was graduated by NYHA class.ResultsMore than one out of three patients (35.1%) complained about hearing loss, 54.4% about vertigo and 28.1% about both symptom. In 74% a sensorineural hearing loss of at least 25 dB was found, ABR could exclude any retrocochlear lesion. Caloric testing showed abnormal values in 71.9%, VEMPs were pathological in 68%. A correlation between the side or the shape of hearing loss and pathological vestibular testing could not be revealed.ConclusionsHearing loss and vertigo show a high prevalence in FD. While hearing loss seems due to a cochlear lesion, peripheral vestibular as well as central nervous pathologies cause vertigo. Thus, both the site of lesion and the pathophysiological patterns seem to differ.Electronic supplementary materialThe online version of this article (10.1186/s13023-018-0882-7) contains supplementary material, which is available to authorized users.
This study aimed to evaluate the feasibility and accuracy of electromagnetic navigation at the lateral skull base in combination with flat panel volume computed tomography (fpVCT) datasets. A mastoidectomy and a posterior tympanotomy were performed on 10 samples of fresh frozen temporal bones. For registration, four self-drilling titanium screws were applied as fiducial markers. Multi-slice computed tomography (MSCT; 600 µm), conventional flat panel volume computed tomography (fpVCT; 466 µm), micro-fpVCT (197 µm) and secondary reconstructed fpVCT (100 µM) scans were performed and data were loaded into the navigation system. The resulting fiducial registration error (FRE) was analysed, and control of the navigation accuracy was performed. The registration process was very quick and reliable with the screws as fiducials. Compared to using the MSCT data, the micro-fpVCT data led to significantly lower FRE values, whereas conventional fpVCT and secondary reconstructed fpVCT data had no advantage in terms of accuracy. For all imaging modalities, there was no relevant visual deviation when targeting defined anatomical points with a navigation probe. fpVCT data are very well suited for electromagnetic navigation at the lateral skull base. The use of titanium screws as fiducial markers turned out to be ideal for comparing different imaging methods. A further evaluation of this approach by a clinical trial is required.
Standard in der Versorgung mit einem Cochleaimplantat (CI) ist eine postoperative Lagekontrolle des Elektrodenträgers. Dadurch soll die angestrebte komplette Insertion aller Elektrodenkontakte und deren intracochleäre Position dokumentiert werden. Eine genaue Darstellung der anatomischen Details ist bei einer konventionellen Röntgenaufnahme nicht möglich, bei der üblichen High-Resolution-Computertomographie gibt nicht selten ausgeprägte Metallartefakte. Die Flachdetektor-Computertomographie (FD-CT) ist neue bildgebende Methode, die ein hohes Auflösungsvermögen und eine Metallartefaktreduktion bietet.
Standard in der Versorgung mit einem Cochleaimplantat (CI) ist eine postoperative Lagekontrolle des Elektrodenträgers. Dadurch soll die angestrebte komplette Insertion aller Elektrodenkontakte und deren intracochleäre Position dokumentiert werden. Eine genaue Darstellung der anatomischen Details ist bei einer konventionellen Röntgenaufnahme nicht möglich, bei der üblichen High-Resolution-Computertomographie gibt nicht selten ausgeprägte Metallartefakte. Die Flachdetektor-Computertomographie (FD-CT) ist neue bildgebende Methode, die ein hohes Auflösungsvermögen und eine Metallartefaktreduktion bietet.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.