Phone: +34 963877650 Fax: +34 963877659 e-mail: vidolrui@mot.upv.es 1 all the parameters, changing each time one specific value. In these sensitivity studies, maximum ideal and real Rankine efficiency value of 19% and 6% were obtained respectively.
This paper deals with the evaluation and analysis of a bottoming ORC cycle coupled to an IC engine by means of conventional and advanced exergy analysis. Using experimental data of an ORC coupled to a 2 l turbocharged engine, both conventional and advanced exergy analysis are carried out. Splitting the exergy in the advanced exergy analysis into unavoidable and avoidable provides a measure of the potential of improving the efficiency of this component. On the other hand, splitting the exergy into endogenous and exogenous provides information between interactions among system components. The result of this study shows that there is a high potential of improvement in this type of cycles. Although, from the conventional analysis, the exergy destruction rate of boiler is greater than the one of the expander, condenser and pump, the advanced exergy analysis suggests that the first priority of improvement should be given to the expander, followed by the pump, the condenser and the boiler. A total amount of 3.75 kW (36.5%) of exergy destruction rate could be lowered, taking account that only the avoidable part of the exergy destruction rate can be reduced.
This paper deals with the thermodynamic analysis of an Absorption Refrigeration Cycle used to cool down the temperature of the intake air in an Internal Combustion Engine using as a heat source the exhaust gas of the engine. The solution of ammonia-water has been selected due to the stability for a wide range of operating temperatures and pressures and the low freezing point. The effects of operating temperatures, pressures, concentrations of strong and weak solutions in the Absorption Refrigeration Cycle were examined to achieve proper heat rejection to the ambient. Potential of increasing Internal Combustion Engine efficiency and reduce pollutant emissions was estimated by means of theoretical models and experimental tests. In order to provide boundary conditions for the absorption refrigeration cycle and to simulate its effect on engine performance, a 0D thermodynamic model was used to reproduce the engine performance when the intake air is cooled. Furthermore, a detailed experimental work was carried out to validate the results in real engine operation. Theoretical results show how the absorption refrigeration system decreases the intake air flow temperature down to a temperature around 5 °C and even lower by using the bottoming waste heat energy available in the exhaust gases in a wide range of engine operating conditions. In addition, the theoretical analysis estimates the potential of the strategy for increasing the engine indicated efficiency in levels up to 4% also at the operating conditions under evaluation. Finally, this predicted benefit in engine indicated efficiency has been experimentally confirmed by direct testing.
This paper presents a mathematical model of a bottoming Organic Rankine Cycle coupled to a 2l turbocharged gasoline engine to optimize the cycle from a thermoeconomic and sizing point of view. These criteria were optimized with different cycle values. Therefore, a methodology to optimize the ORC coupled to Waste Heat Recovery systems in vehicle applications is presented using a multiobjective optimization algorithm. Multi-objective optimization results show that the optimum solution depend on the importance of each objective to the final solution. Considering thermo-economic criteria as the main objective, greater sizes will be required. Considering sizing criteria as the main objective, higher thermoeconomic parameters will be obtained. Therefore, in order to select a singlesolution from the Pareto frontier, a multiple attribute decision-making method (TOPSIS) was implemented in order to take into account the preferences of the Decision Maker. Considering the weight factors 0.5 for Specific Investment Cost (SIC), 0.3 for the area of the heat exchangers (Atot) and 0.2 for Volume Coefficient (VC) and the boundaries of this particular application, the result is optimized with
This paper deals with the experimental testing of a bottoming Organic Rankine Cycle (ORC) integrate in a 2 liter turbocharged gasoline engine using ethanol as working fluid. The main components of the cycle are a boiler, a condenser, a pump and a swash-plate expander. Both steady and transient tests were performed in three engine operating points to understand the behavior and inertia of the system. Pressure-Volume diagram during these transients were presented and analyzed. Operating parameters of the expander, such as expander speed and boiler power, were shifted. The objective of these tests is to understand the inertia of the system and to have a robust control in all the possible transient tests.New European Driving Cycle was tested with and without the expander because
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.