Background and Aim
Dialysis patients are a high-risk population and have a reduced immune response to vaccination against SARS-CoV-2. The aim of this study was to assess the humoral response to homologous Gam-COVID-Vac (Sputnik V) and heterologous Sputnik V/mRNA-1273 (Moderna) vaccination in dialysis patients. The vaccination scheme depended on dose availability and the prioritization of risk populations as established by the Argentine Ministry of Health.
Methods
Previous COVID-19 infection was determined in symptomatic patients. Binding IgG antibodies against the spike (S) receptor-binding domain (RBD) of SARS-CoV-2 (anti-S-RBD) concentration was assessed between 3 and 16 weeks after the boost dose. Anti-S-RBD antibodies were quantified using the Abbott Diagnostics SARS-CoV-2 IgG II Quant chemiluminescent microparticle immunoassay (CMIA) on an Architect i2000 SR and an Alinity I analyzer (Abbott Diagnostics, Abbott Park, Illinois, USA). To standardize the results to WHO binding antibody units (BAU), a correction factor for Abbott arbitrary units (AU) was applied where 1 BAU/mL equals 0.142 AU, as previously established by Abbott with the WHO international standard NIBSC 20–136. Following the manufacturer’s recommendations, samples were considered reactive for anti-S-RBD when titers were above 50 AU/mL (7.2 BAU/mL). An 80% protective effect (PROT-80) against symptomatic SARS-CoV-2 infection was assumed when anti-S-RBD titers were 506 BAU/ml or higher. Charlson Comorbidity Index (CCI) score was classified as mild = 1–2, moderate = 3–4, and severe ≥ 5. Side effects were evaluated until day 7 by patients´ self-reported questionnaire.
Results
One hundred seven participants were enrolled [
n
= 84 homologous (SpV/SpV), nn 23 heterologous (SpV/Mod)]. Median (IQR) age was 64 (50–75) years old and 79 (73.8%) were male. Additionally, 19 (22.6%) of the SpV/SpV and 4 (17.4%) of the SpV/Mod group had a prior confirmed SARS-CoV-2 infection (
p
= 0.589). In the overall population, 103 patients reached seroconversion (96.3%). Anti-S-RBD IgG median titers (IQR) were higher in the heterologous [1222 (288–5680) BAU/mL] than in the homologous scheme [447 (100–1551) BAU/mL],
p
= 0.022. In a linear model adjusted for age, gender, days from first vaccination to boost dose and days from the boost dose to the anti-S-RBD IgG determination, previous SARS-COV-2 infection (B: 2062.2; CI95: 1231.8–2892.6;
p
< 0.001), and SpV/Mod vaccination scheme (B: 1294.6; CI95: 435.58–2147.6;
p
= 0.003) were independently associated with anti-S-RBD levels. Finally, a higher frequency of adverse effects was associated with the heterologous scheme, although they were well tolerated by all individuals.
Conclusions
The present study provides evidence that the homologous SpV/SpV and heterologous SpV/Mod schemes showed good e...
Introduction: The humoral response to vaccines is the most used tool to evaluate the protection against SARS-CoV-2 infection. Dialysis patients are a high-risk population and have a reduced immune response to vaccination.
Objective: To assess the humoral response to homologous Gam-COVID-Vac (Sputnik V) and heterologous Sputnik V/mRNA-1273 (Moderna) vaccination in dialysis patients.
Methods: SARS-CoV-2 anti-spike IgG (RBD) concentration was estimated 3-16 weeks after complete vaccination. Reactogenicity was evaluated until day 7 by patients self-reported side events.
Results: 107 participants were enrolled [n=84 homologous (SpV/SpV), n=23 heterologous (SpV/Mod)]. Median (IQR) age was 64 (50-75) years old and 79 (73.8%) were male. Additionally, 19 (22.6%) of the SpV/SpV and 4 (17.4%) of the SpV/Mod group had a prior confirmed SARS-CoV-2 infection (p=0.589). In the overall population, 103 patients reached seroconversion (96.3%). Anti-S-RBD IgG median titers (IQR) were higher in the heterologous [1222 (288-5680) BAU/mL] than in the homologous scheme [447 (100-1551) BAU/mL], p=0.022. In a linear model adjusted for age and gender, previous SARS-COV-2 infection (B: 1944.3; CI95: 1136.2-2753.4; p<0.001), and SpV/Mod vaccination scheme (B: 1241.5; CI95: 420.39-2062.6; p=0.003) were independently associated with anti-S-RBD levels. Finally, a higher frequency of adverse effects was associated with the heterologous scheme, although they were well tolerated by all individuals.
Conclusion: The present study provides evidence that the homologous SpV/SpV and heterologous SpV/Mod schemes showed good efficacy and safety under dialysis conditions. These results could be useful for future vaccination strategies, especially aimed at this risk group.
Introduction.The COVID-19 pandemic has brought to light the need for rapid diagnostic tests. The gold standard test is reverse transcription-polymerase chain reaction (RT-PCR). RT-PCR requires equipment and trained personnel, and results may take a long waiting time. The BD Veritor® System is a rapid chromatographic method used for the detection of severe acute respiratory syndrome coronavirus 2 antigen in symptomatic individuals. The primary objective of this study is to assess the sensitivity and specificity of the antigen test (AT) compared to the RT-PCR in the pediatric population.
Population and methods.Prospective study with a diagnostic test. All children younger than 17 years in the first 5 days of symptom onset, who consulted between July 2021 and February 2022, were included. A minimum of 300 specimens was estimated to achieve an accuracy of ±8.76% and ±3.68% for sensitivity and specificity, respectively. Specimens were analyzed in parallel using both methodologies.Results. Of 316 paired samples, 33 were positive by both methods; 6 were positive only by RT-PCR. The specificity of the AT was 100%; sensitivity was 84.6%, with a positive and negative predictive value of 100% and 98%, respectively.
Conclusions.The AT proved to be useful in the diagnosis of pediatric patients with COVID-19 in the first 5 days of symptom onset, although those with a negative AT and high clinical suspicion should confirm their result with a RT-PCR.Clinical trial registration: PRIISA.BA -Record number: 4912 -Date of registration: 07/07/2021.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.