Our study did not show a significant increase in mortality in patients whose surgery was delayed by more than 2 days. However, in the context of other published work, we would continue to recommend early surgery to minimize length of stay and complications.
Summary Delirium is a common complication following hip fracture surgery. We introduced a peri‐operative care bundle that standardised management in the emergency department, operating theatre and ward. This incorporated: use of fascia iliaca blocks; rationalisation of analgesia; avoidance of drugs known to trigger delirium; a regular education program for staff; and continuous auditing of compliance. The study was conducted between June 2017 and December 2018. We recruited 150 patients before (control group) and 150 patients after (care bundle group) the introduction of the care bundle. In patients having surgery for a hip fracture, there was a lower incidence of delirium on the third postoperative day in the care bundle group compared with the control group (33 patients (22%) vs. 49 patients (33%)), respectively; p = 0.04). Patients in the care bundle group had an adjusted OR of 2.2 (95%CI 1.1–4.4) (p = 0.03) for the avoidance of delirium on the third postoperative day. There was no difference between groups for the secondary outcome measures (measured at 30 days postoperatively) including: all‐cause mortality; composite morbidity; institutionalisation; and walking status. During the study period, compliance with elements of the care bundle improved in the emergency department (49 patients (33%) compared with 85 patients (59%); p < 0.001) and anaesthetic department (40 patients (27%) compared with 104 patients (69%); p < 0.001), while orthogeriatrics maintained a high level of compliance (140 patients (93%) compared with 143 patients (95%); p = 0.45). There was a clinically and statistically significant reduction in the incidence of delirium following hip fracture surgery in patients treated with a multidisciplinary care bundle.
Anterior exposure of the thoracic spine using a mini-open thoracotomy and retropleural approach coupled with a limited bony resection surrounding the giant disc, without corpectomy or instrumentation, represents an effective, safe, and appropriate surgical treatment for the resection of giant thoracic discs.
Pedicle screw fixation has achieved significant popularity amongst spinal surgeons for both single and multi-level spinal fusion. Misplacement and pedicle cortical violation occurs in over 20% of screw placement and can result in potential complications such as dysthesia, paraparesis or paraplegia. There have been many advances in techniques available for navigating through the pedicle; however, these techniques are not without drawbacks. A new electrical conductivity-measuring device, previously evaluated on the porcine model to detect the pedicle violation, was evaluated amongst nine European Hospitals to be used in conjunction with the methods currently used in that centre. This new device is based on two original principles; the device is integrated in the drilling or screwing tool. The technology allows real-time detection of perforation through two independent parameters, impedance variation and evoked muscle contractions. Data was collected twofold. Initially, the surgeon was given the device and a comparison was made between the devices ability to detect a breech and the surgeon's ability to detect one using his traditional methods of pedicle preparation. In the second module of the study, the surgeon was limited to using the electrical conductivity detection device as their sole guide to detect pedicle breaches. A comparison was made between the detection ability of the device and the other detection possibilities. Post-operative fine cut CT scanning was used to detect the pedicle breaches. Overall, the 11 trial surgeons performed a total of 521 pedicle drillings on 97 patients. Initially there were 147 drillings with 23 breaches detected. The detection rate of these breaches were 22/23 for the device compared to 10/23 by the surgeon. Over both parts of the study 64 breaches (12.3%) were confirmed on post-operative CT imaging. The electrical conductivity detection device detected 63 of the 64 breaches (98.4%). There was one false negative and four false positives. This gives the device an overall sensitivity of 98% and specificity of 99% for detecting a pedicle breach. The negative predictive value was 99.8%, with a positive predictive value of 94%. No adverse event was noted with the use of the electrical conductivity device. Electrical conductivity monitoring may provide a
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.