Elsevier has created a COVID-19 resource centre with free information in English and Mandarin on the novel coronavirus COVID-19. The COVID-19 resource centre is hosted on Elsevier Connect, the company's public news and information website. Elsevier hereby grants permission to make all its COVID-19-related research that is available on the COVID-19 resource centre-including this research content-immediately available in PubMed Central and other publicly funded repositories, such as the WHO COVID database with rights for unrestricted research re-use and analyses in any form or by any means with acknowledgement of the original source. These permissions are granted for free by Elsevier for as long as the COVID-19 resource centre remains active.
The ProGastro Cd assay (Prodesse, Inc., Waukesha, WI) is a new commercial TaqMan PCR assay that detects tcdB. The ProGastro Cd assay was compared to the Wampole Clostridium difficile toxin B test (TOX-B test; TechLab, Blacksburg, VA), a cell culture cytotoxicity neutralization assay (CCCNA), and to anaerobic toxigenic bacterial culture, as the "gold standard," for 285 clinical stool specimens. Assays were independently performed according to manufacturers' directions. A 1.0-ml sample was removed from the stool specimen, of which 20 l was used for extraction on the NucliSENS easyMAG platform (bioMérieux, Inc., Durham, NC) for the Prodesse ProGastro Cd assay and 200 l of the stool filtrate was used for the TOX-B CCCNA. Anaerobic toxigenic culture was done by heating an additional 1.0 ml of the stool sample to 80°C for 10 min before inoculation onto modified cycloserine, cefoxitin, and fructose agar with horse blood (Remel, Lenexa, KS) and into a prereduced chopped meat glucose broth (BBL, BD Diagnostics, Sparks, MD). The prevalence of toxin-producing strains of C. difficile was 15.7% (n ؍ 44) as determined by anaerobic toxigenic culture. The sensitivity, specificity, and positive and negative predictive values of the Prodesse ProGastro Cd assay compared to the TOX-B test were 83.3%, 95.6%, 69.4%, and 98%, respectively. Compared to toxigenic culture, the sensitivity, specificity, and positive and negative predictive values of the Prodesse ProGastro Cd assay were 77.3%, 99.2%, 94.4%, and 95.9%, respectively, and those of the TOX-B test were 63.6%, 99.2%, 93.3%, and 93.6%, respectively. Although no statistical difference (Fisher's exact test) was detected (P ؍ 0.242) between the sensitivities of the Prodesse ProGastro Cd assay and a standard CCCNA compared to anaerobic culture for the detection of toxigenic C. difficile, the Prodesse ProGastro Cd assay did detect more toxigenic C. difficile isolates than the CCCNA.
Rapid (2.5-to 3.5-h) enzyme immunoassays (EIAs) for the detection of Clostridium dif/icile toxins have been developed. We report the results of simultaneous testing of 700 fresh stool specimens by the tissue culture cytotoxin assay and four EIAs (Bartels Prima System C. diJficile Toxin A EIA, Cambridge Biotech Cytoclone A+B EIA, Meridian Diagnostics Premier C. diJicile Toxin A EIA, and TechLab C. dijficile Tox-A Test EIA). In cases of disagreement, culturing for toxigenic C. dijficile was performed. A total of 61 (8.7%) specimens from 46 patients were positive for C. difficile toxin. The sensitivity of the cytotoxin assay was 87%, and that of culture was 93%. In comparison with the cytotoxin assay results, the sensitivity and specificity of the EIAs were as follows: Bartels, 87 and 96%; Cambridge, 89 and 99%; Meridian, 87 and 98%; and TechLab, 87 and 95%, respectively. In comparison with the cytotoxin assay plus toxigenic culture results, the sensitivity and specificity of the EIAs were as follows: Bartels, 84 and 97%; Cambridge, 85 and 99%YO; Meridian, 79 and 98%; and TechLab, 80 and 96%, respectively. The EIAs varied in positive predictive values (PPVs). A high PPV was seen with the Cambridge EIA (96%); lower PPVs were seen with the TechLab (64%), Bartels (72%), and Meridian (80%) EIAs because of high false-positive rates. The negative predictive values (98 to 99%o) were excellent with all EIAs. Results were indeterminant with 0.3% of the samples by the Meridian EIA and 3% by all the other EIAs. Although the EIAs were less sensitive than the cytotoxin assay, they provide same-day results and may be useful in laboratories without tissue culture facilities.
Highlights SARS-CoV-2 molecular assays are the current gold standard for diagnosis and large scale screening. Performance of the highly automated high throughput NeuMoDx assay for SARS-CoV-2 was evaluated. Data collected from three centers: Johns Hopkins Hospital, St. Jude Children’s Research Hospital, and the Wadsworth Center.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.