Obligatory measurements of the potential alpha energy concentration of short-lived radon progeny have been performing in the Polish underground mines since 1989. In consideration of economic aspects, an attempt was made from the very beginning to combine it with measurements of the dust concentration. Therefore the developed measuring units were an integral part of the dust samplers complying with the requirements of the State Mining Authority to apply them in underground mines. This way the developed devices could fulfil two measurement tasks simultaneously: measurement of the dust concentration and potential alpha energy concentration of short-lived radon progeny. The new device based on the thermoluminescence detectors is able to cooperate with the dust samplers made by the SKC company and equipped with a cyclone making it possible to operate them constantly for one working day. The lower limit of detection was equal about 0.04 microJ m(-3) at a 95% confidence level and 1 h pumping.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.