Background Exercise after paralysis can help prevent secondary health complications, but achieving adequate exercise volumes and intensities is difficult with loss of motor control. Existing electrical stimulation-driven cycling systems involve the paralyzed musculature but result in rapid force decline and muscle fatigue, limiting their effectiveness. This study explores the effects of selective stimulation patterns delivered through multi-contact nerve cuff electrodes on functional exercise output, with the goal of increasing work performed and power maintained within each bout of exercise. Methods Three people with spinal cord injury and implanted stimulation systems performed cycling trials using conventional (S-Max), low overlap (S-Low), low duty cycle (C-Max), and/or combined low overlap and low duty cycle (C-Low) stimulation patterns. Outcome measures include total work (W), end power (Pend), power fluctuation indices (PFI), charge accumulation (Q), and efficiency (η). Mann–Whitney tests were used for statistical comparisons of W and Pend between a selective pattern and S-Max. Welch’s ANOVAs were used to evaluate differences in PFIs among all patterns tested within a participant (n ≥ 90 per stimulation condition). Results At least one selective pattern significantly (p < 0.05) increased W and Pend over S-Max in each participant. All selective patterns also reduced Q and increased η compared with S-Max for all participants. C-Max significantly (p < 0.01) increased PFI, indicating a decrease in ride smoothness with low duty cycle patterns. Conclusions Selective stimulation patterns can increase work performed and power sustained by paralyzed muscles prior to fatigue with increased stimulation efficiency. While still effective, low duty cycle patterns can cause inconsistent power outputs each pedal stroke, but this can be managed by utilizing optimized stimulation levels. Increasing work and sustained power each exercise session has the potential to ultimately improve the physiological benefits of stimulation-driven exercise.
Neural stimulation systems are often limited by rapid muscle fatigue. Selective nerve cuff electrodes can target independent yet synergistic motor unit pools (MUPs), which can be used in duty-cycle reducing stimulation paradigms to prolong joint moment output. Objective: This study investigates waveform parameters within moment-prolonging paradigms and determines strategies for their optimal implementation. Methods: Composite flat-interface nerve cuff electrodes (C-FINEs) were chronically implanted on feline proximal sciatic nerves. Cyclic stimulation tests determined effects of stimulation period and duty cycle in different MUP types. Ideal parameters were then used in duty-cycle reducing carousel stimulation. Time to 50% reduction in moment (T50), moment overshoot, and moment ripple were determined for constant, open-loop carousel, and moment feedback-controlled closedloop carousel stimulation. Results: A stimulation period of 1 s best maintained joint moment for all MUPs. Low (25%) duty cycles consistently improved joint moment maintenance, though allowable duty cycle varied among MUPs by gross muscle and fiber type. Both open-and closed-loop carousel stimulation significantly increased T50 over constant stimulation. Closed-loop carousel significantly decreased moment overshoot over the other conditions, and significantly decreased moment ripple compared with open-loop stimulation. Conclusion: Selectivity-enabled carousel stimulation prolongs joint moment over conventional constant stimulation. Appropriate waveform parameters can be quickly determined for individual MUPs and stimulation can be controlled for additional performance improvements with this paradigm. Significance: Providing prolonged, stable joint moment and muscle output to recipients of motor neuroprostheses will improve clinical outcomes, increase independence, and positively impact quality of life.
Neuroprostheses that activate musculature of the lower extremities can enable standing and movement after paralysis. Current systems are functionally limited by rapid muscle fatigue induced by conventional, non-varying stimulus waveforms. Previous work has shown that sum of phase-shifted sinusoids (SOPS) stimulation, which selectively modulates activation of individual motor unit pools (MUPs) to lower the duty cycle of each while maintaining a high net muscle output, improves joint moment maintenance but introduces greater instability over conventional stimulation. In this case study, implementation of SOPS stimulation with a real-time feedback controller successfully decreased joint moment instability and further prolonged joint moment output with increased stimulation efficiency over open-loop approaches in one participant with spinal cord injury. These findings demonstrate the potential for closed-loop SOPS to improve functionality of neuroprosthetic systems.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.