PurposeSince the introduction of positron emission tomography (PET) imaging with 68Ga-PSMA-HBED-CC (=68Ga-DKFZ-PSMA-11), this method has been regarded as a significant step forward in the diagnosis of recurrent prostate cancer (PCa). However, published data exist for small patient cohorts only. The aim of this evaluation was to analyse the diagnostic value of 68Ga-PSMA-ligand PET/CT in a large cohort and the influence of several possibly interacting variables.MethodsWe performed a retrospective analysis in 319 patients who underwent 68Ga-PSMA-ligand PET/CT from 2011 to 2014. Potential influences of several factors such as prostate-specific antigen (PSA) level and doubling time (DT), Gleason score (GSC), androgen deprivation therapy (ADT), age and amount of injected tracer were evaluated. Histological verification was performed in 42 patients after the 68Ga-PSMA-ligand PET/CT. Tracer uptake was measured in 901 representative tumour lesions.ResultsIn 82.8 % of the patients at least one lesion indicative of PCa was detected. Tumor-detection was positively associated with PSA level and ADT. GSC and PSA-DT were not associated with tumor-detection. The average maximum standardized uptake value (SUVmax) of tumour lesions was 13.3 ± 14.6 (0.7–122.5). Amongst lesions investigated by histology, 30 were false-negative in 4 different patients, and all other lesions (n = 416) were true-positive or true-negative. A lesion-based analysis of sensitivity, specificity, negative predictive value (NPV) and positive predictive value (PPV) revealed values of 76.6 %, 100 %, 91.4 % and 100 %. A patient-based analysis revealed a sensitivity of 88.1 %. Of 116 patients available for follow-up, 50 received local therapy after 68Ga-PSMA-ligand PET/CT.Conclusion68Ga-PSMA-ligand PET/CT can detect recurrent PCa in a high number of patients. In addition, the radiotracer is highly specific for PCa. Tumour detection is positively associated with PSA and ADT. 68Ga-PSMA-ligand PET/CT can help delay systemic therapy of PCa.Electronic supplementary materialThe online version of this article (doi:10.1007/s00259-014-2949-6) contains supplementary material, which is available to authorized users.
The aim of this guideline is to provide standards for the recommendation, performance, interpretation and reporting of Ga-PSMA PET/CT for prostate cancer imaging. These recommendations will help to improve accuracy, precision, and repeatability ofGa-PSMA PET/CT for prostate cancer essentially needed for implementation of this modality in science and routine clinical practice.
PurposeThe prostate-specific membrane antigen (PSMA) targeted positron-emitting-tomography (PET) tracer 68Ga-PSMA-11 shows great promise in the detection of prostate cancer. However, 68Ga has several shortcomings as a radiolabel including short half-life and non-ideal energies, and this has motivated consideration of 18F-labelled analogs. 18F-PSMA-1007 was selected among several 18F-PSMA-ligand candidate compounds because it demonstrated high labelling yields, outstanding tumor uptake and fast, non-urinary background clearance. Here, we describe the properties of 18F-PSMA-1007 in human volunteers and patients.MethodsRadiation dosimetry of 18F-PSMA-1007 was determined in three healthy volunteers who underwent whole-body PET-scans and concomitant blood and urine sampling. Following this, ten patients with high-risk prostate cancer underwent 18F-PSMA-1007 PET/CT (1 h and 3 h p.i.) and normal organ biodistribution and tumor uptakes were examined. Eight patients underwent prostatectomy with extended pelvic lymphadenectomy. Uptake in intra-prostatic lesions and lymph node metastases were correlated with final histopathology, including PSMA immunostaining.ResultsWith an effective dose of approximately 4.4–5.5 mSv per 200–250 MBq examination, 18F-PSMA-1007 behaves similar to other PSMA-PET agents as well as to other 18F-labelled PET-tracers. In comparison to other PSMA-targeting PET-tracers, 18F-PSMA-1007 has reduced urinary clearance enabling excellent assessment of the prostate. Similar to 18F-DCFPyL and with slightly slower clearance kinetics than PSMA-11, favorable tumor-to-background ratios are observed 2–3 h after injection. In eight patients, diagnostic findings were successfully validated by histopathology. 18F-PSMA-1007 PET/CT detected 18 of 19 lymph node metastases in the pelvis, including nodes as small as 1 mm in diameter.Conclusion 18F-PSMA-1007 performs at least comparably to 68Ga-PSMA-11, but its longer half-life combined with its superior energy characteristics and non-urinary excretion overcomes some practical limitations of 68Ga-labelled PSMA-targeted tracers.Electronic supplementary materialThe online version of this article (doi:10.1007/s00259-016-3573-4) contains supplementary material, which is available to authorized users.
Despite many advances in the past years, the treatment of metastatic prostate cancer still remains challenging. In recent years, prostate-specific membrane antigen (PSMA) inhibitors were intensively studied to develop low-molecular-weight ligands for imaging prostate cancer lesions by PET or SPECT. However, the endoradiotherapeutic use of these compounds requires optimization with regard to the radionuclide-chelating agent and the linker moiety between chelator and pharmacophore, which influence the overall pharmacokinetic properties of the resulting radioligand. In an effort to realize both detection and optimal treatment of prostate cancer, a tailor-made novel naphthyl-containing DOTA-conjugated PSMA inhibitor has been developed. Methods: The peptidomimetic structure was synthesized by solid-phase peptide chemistry and characterized using reversedphase high-performance liquid chromatography and matrix-assisted laser desorption/ionization mass spectrometry. Subsequent 67/68 Ga and 177 Lu labeling resulted in radiochemical yields of greater than 97% or greater than 99%, respectively. Competitive binding and internalization experiments were performed using the PSMA-positive LNCaP cell line. The in vivo biodistribution and dynamic small-animal PET imaging studies were investigated in BALB/c nu/nu mice bearing LNCaP xenografts. Results: The chemically modified PSMA inhibitor PSMA-617 demonstrated high radiolytic stability for at least 72 h. A high inhibition potency (equilibrium dissociation constant [K i ] 5 2.34 ± 2.94 nM on LNCaP; K i 5 0.37 ± 0.21 nM enzymatically determined) and highly efficient internalization into LNCaP cells were demonstrated. The small-animal PET measurements showed high tumor-tobackground contrasts as early as 1 h after injection. Organ distribution revealed specific uptake in LNCaP tumors and in the kidneys 1 h after injection. With regard to therapeutic use, the compound exhibited a rapid clearance from the kidneys from 113.3 ± 24.4 at 1 h to 2.13 ± 1.36 percentage injected dose per gram at 24 h. The favorable pharmacokinetics of the molecule led to tumor-to-background ratios of 1,058 (tumor to blood) and 529 (tumor to muscle), respectively, 24 h after injection. Conclusion: The tailor-made DOTA-conjugated PSMA inhibitor PSMA-617 presented here is sustainably refined and advanced with respect to its tumor-targeting and pharmacokinetic properties by systematic chemical modification of the linker region. Therefore, this radiotracer is suitable for a first-in-human theranostic application and may help to improve the clinical management of prostate cancer in the future.
The salivary glands and kidneys showed high, but not critical, absorbed doses after RLT with (177)Lu-DKFZ-PSMA-617. We suggest that (177)Lu-DKFZ-PSMA-617 is suitable for radiotherapy, offering tumour-to-kidney ratios comparable to those with RLT agents currently available for the treatment of neuroendocrine tumours. Our dosimetry results suggest that (177)Lu-DKFZ-PSMA-617 treatment with higher activities and more cycles is possible without the risk of damaging the kidneys.
PurposeSince the clinical introduction of 68Ga-PSMA-11 PET/CT, this imaging method has rapidly spread and is now regarded as a significant step forward in the diagnosis of recurrent prostate cancer (PCa). The aim of this study was to analyse the influence of several variables with possible influence on PSMA ligand uptake in a large cohort.MethodsWe performed a retrospective analysis of 1007 consecutive patients who were scanned with 68Ga-PSMA-11 PET/CT (1 h after injection) from January 2014 to January 2017 to detect recurrent disease. Patients with untreated primary PCa or patients referred for PSMA radioligand therapy were excluded. The possible effects of different variables including PSA level and PSA doubling time (PSADT), PSA velocity (PSAVel), Gleason score (GSC, including separate analysis of GSC 7a and 7b), ongoing androgen deprivation therapy (ADT), patient age and amount of injected activity were evaluated.ResultsIn 79.5% of patients at least one lesion with characteristics suggestive of recurrent PCa was detected. A pathological (positive) PET/CT scan was associated with PSA level and ADT. GSC, amount of injected activity, patient age, PSADT and PSAVel were not associated with a positive PET/CT scan in multivariate analysis.Conclusion 68Ga-PSMA-11 PET/CT detects tumour lesions in a high percentage of patients with recurrent PCa. Tumour detection is clearly associated with PSA level and ADT. Only a tendency for an association without statistical significance was found between higher GSC and a higher probability of a pathological PET/CT scan. No associations were found between a pathological 68Ga-PSMA-11 PET/CT scan and patient age, amount of injected activity, PSADT or PSAVel. Electronic supplementary materialThe online version of this article (doi:10.1007/s00259-017-3711-7) contains supplementary material, which is available to authorized users.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
334 Leonard St
Brooklyn, NY 11211
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.