A study was conducted on 20 patients who underwent tricuspid valve replacement (TVR) with the St. Jude Medical (SJM) valve. Isolated TVR was performed on 9 patients, and additional mitral, or mitral and aortic valve replacements were performed on 11 patients. Four patients (20%) died in the early postoperative period, but there were no deaths related to the SJM valve in the tricuspid position. The mean follow-up period of the 16 survivors was 74.4 months, and there have been no deaths during the follow-up period. The postoperative actuarial survival rate was 80%, 10 years after surgery. Three patients, representing 0.25%/patient-months, developed valve thrombosis, the valve thrombosis-free rate being 72.8%, 10 years after surgery, while entrapment of a leaflet by endothelial pannus was found in one patient, representing 0.08%/patient-months. Thus, the incidence of all prosthetic valve-related complications was 0.34%/patient-months, and the postoperative complication-free rate was 65.3%, 10 years after surgery. The medium-term follow-up study of TVR with the SJM valve revealed no prosthetic valve-related deaths and a relatively low incidence of prosthetic valve-related complications. However, as with other mechanical valves, valve thrombosis was a major risk posed by the SJM valve in the tricuspid position.
Between January 1982 and November 1992, 38 patients received simultaneous mitral valve replacement (MVR) and left atrial plication (LAP) because of giant left atrium accompanying mitral lesion. Their ages ranged from 33 to 70 years, and the mitral lesion was caused by rheumatic heart disease in all patients. MVR was performed with a St. Jude Medical prosthesis for all patients and the left atrial wall was plicated with running 3-0 Nespolene to reduce the width to 3 to 5 cm. Respiration requiring mechanical ventilation more than 48 hours after operation occurred in four patients (10.5%) and postoperative low cardiac output requiring a high dose of dopamine HCl or intraaortic balloon pumping in nine patients (23.7%). The left atrial diameter measured by echocardiogram was a mean of 7.3 +/- 1.0 cm before operation and 5.8 +/- 1.0 cm postoperatively. The cardiothoracic ratio on the chest roentgenogram registered a preoperative mean of 73.3% +/- 9.8% and was 65.7% +/- 8.4% after operation. The pre- and postoperative values were significantly different (p < 0.01). The postoperative exercise level was a mean of 5.3 metabolic units for 24 patients and the postoperative New York Heart Association functional classification indicated Class I or II for 37 patients with no evidence of left atrial thrombus except in the case of one early death. LAP with MVR for patients with giant left atrium due to mitral lesion appeared to result in improvement in respiratory and circulatory functions.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.