PurposeTo investigate the vascular microcirculation changes in the retinal nerve fiber layer (RNFL) in normal, glaucoma suspect, and open-angle glaucoma (OAG) groups using optical coherence tomography–based microangiography (OMAG).MethodsOne eye from each subject was scanned with a Cirrus HD-OCT 5000–based OMAG prototype system montage scanning protocol centered at the optic nerve head (ONH). Blood flow signals were extracted using OMAG algorithm. Retinal nerve fiber layer vascular microcirculation was measured by calculating the blood flux index and vessel area density within a 1.2-mm width annulus centered at the ONH with exclusion of big retinal vessels. One-way ANOVA were performed to analyze the RNFL microcirculation among groups. Linear-regression models were constructed to analyze the correlation between RNFL microcirculation and clinical parameters. Discrimination capabilities of the flow metrics were assessed with the area under the receiver operating characteristic curve (AROC).ResultsTwenty normal, 26 glaucoma suspect, and 42 OAG subjects were enrolled. Eyes from OAG subjects and glaucoma suspects showed significantly lower blood flux index compared with normal eyes (P ≤ 0.0015). Retinal nerve fiber layer blood flow metrics showed significant correlations with visual field indices and structural changes in glaucomatous eyes (P ≤ 0.0123). Similar discrimination capability of blood flux index compared with RNFL thickness was found in both disease groups.ConclusionsPeripapillary RNFL vascular microcirculation measured as blood flux index by OMAG showed significant differences among OAG, glaucoma suspect, and normal controls and was significantly correlated with functional and structural defects. Retinal nerve fiber layer microcirculation measurement using OMAG may help physicians monitor glaucoma.
PurposeTo investigate optic disc perfusion differences in normal, primary open-angle glaucoma (POAG), and normal tension glaucoma (NTG) eyes using optical microangiography (OMAG) based optical coherence tomography (OCT) angiography technique.DesignCross-sectional, observational study.SubjectsTwenty-eight normal, 30 POAG, and 31 NTG subjects.MethodsOne eye from each subject was scanned with a 68 kHz Cirrus HD-OCT 5,000-based OMAG prototype system centered at the optic nerve head (ONH) (Carl Zeiss Meditec Inc, Dublin, CA). Microvascular images were generated from the OMAG dataset by detecting the differences in OCT signal between consecutive B-scans. The pre-laminar layer (preLC) was isolated by a semi-automatic segmentation program.Main Outcome MeasuresOptic disc perfusion, quantified as flux, vessel area density, and normalized flux (flux normalized by the vessel area) within the ONH.ResultsGlaucomatous eyes had significantly lower optic disc perfusion in preLC in all three perfusion metrics (p<0.0001) compared to normal eyes. The visual field (VF) mean deviation (MD) and pattern standard deviation (PSD) were similar between the POAG and NTG groups, and no differences in optic disc perfusion were observed between POAG and NTG. Univariate analysis revealed significant correlation between optic disc perfusion and VF MD, VF PSD, and rim area in both POAG and NTG groups (p≤0.0288). However, normalized optic disc perfusion was correlated with some structural measures (retinal nerve fiber layer thickness and ONH cup/disc ratio) only in POAG eyes.ConclusionsOptic disc perfusion detected with OMAG was significantly reduced in POAG and NTG groups compared to normal controls, but no difference was seen between POAG and NTG groups with similar levels of VF damage. Disc perfusion was significantly correlated with VF MD, VF PSD, and rim area in glaucomatous eyes. Vascular changes at the optic disc as measured using OMAG may provide useful information for diagnosis and monitoring of glaucoma.
IMPORTANCE Understanding the differences in vascular microcirculation of the peripapillary retinal nerve fiber layer (RNFL) between the hemispheres in eyes with glaucoma with single-hemifield visual field (VF) defects may provide insight into the pathophysiology of glaucoma.OBJECTIVE To investigate the changes in the microcirculation of the peripapillary RNFL of eyes with glaucoma by using optical microangiography. DESIGN, SETTING, AND PARTICIPANTSEyes with glaucoma and single-hemifield VF defect and normal eyes underwent scanning using an optical microangiography system covering a 6.7 × 6.7-mm 2 area centered at the optic nerve head. The RNFL microcirculation was measured within an annulus region centered at the optic nerve head divided into superior and inferior hemispheres. Blood flux index (the mean flow signal intensity in the vessels) and vessel area density (the percentage of the detected vessels in the annulus) were measured. MAIN OUTCOMES AND MEASURESDifferences in microcirculation between the hemispheres in eyes with glaucoma and normal eyes and correlations among blood flow metrics, VF thresholds, and clinical optical coherence tomography structural measurements were assessed.RESULTS Twenty-one eyes from 21 patients with glaucoma (7 men and 14 women; mean [SD] age, 63.7 [9.9] years) and 20 eyes from 20 healthy control individuals (9 men and 11 women; mean [SD] age, 68.3 [10.7] years) were studied. In eyes with glaucoma, the abnormal hemisphere showed a thinner RNFL (mean [SE] difference, 23.5 [4.5] μm; 95% CI, 15.1-32.0 μm; P < .001), lower RNFL blood flux index (mean [SE] difference, 0.04 [0.01]; 95% CI, 0.02-0.05; P < .001), and less vessel area density (mean [SE] difference, 0.08% [0.02%]; 95% CI, 0.05%-0.10%; P < .001) than did the normal hemisphere. Compared with normal eyes, reduced RNFL microcirculation was found in the normal hemisphere of eyes with glaucoma, measured by mean [SE] differences in blood flux index (0.06 [0.01]; 95% CI, 0.04-0.09; P < .001) and vessel area density (0.04% [0.02%]; 95% CI, 0.02%-0.08%; P = .003) but not in RNFL thickness (3.4 [4.7] μm; 95% CI, −6.2 to 12.9 μm; P = .48). Strong correlations were found between the blood flux index and VF mean deviation (Spearman ρ = 0.44; P = .045) and RNFL thickness (Spearman ρ = 0.65; P = .001) in the normal hemisphere of the eye with glaucoma.CONCLUSIONS AND RELEVANCE Reduced RNFL microcirculation was detected in the normal hemisphere of eyes with glaucoma, with strong correspondence with VF loss and RNFL thinning. Although the results suggest that vascular dysfunction precedes structural changes seen in glaucoma, longitudinal studies would be needed to confirm this finding.
Background: To investigate the differences of perfusion in the optic nerve head (ONH) between normal and glaucomatous eyes using optical microangiography (OMAG) based optical coherence tomography (OCT) angiography technique.Methods: One eye from each subject was scanned with a 68 kHz Cirrus 5000 HD-OCT-based OMAG prototype system centered at the ONH (Carl Zeiss Meditec Inc, Dublin, CA, USA). Microvascular images were generated from the OMAG dataset by detecting the differences in OCT signal between consecutive B-scans. The pre-laminar layer (preLC) was isolated by a semi-automatic segmentation program. En face OMAG images for preLC were generated using signals with highest blood flow signal intensity. ONH Results: Twenty normal and 21 glaucoma subjects were enrolled. Glaucomatous eyes had significantly lower ONH perfusion in preLC in all three perfusion metrics compared to normal eyes (P≤0.0003).Significant correlations between ONH perfusion and disease severity as well as structural changes were detected in glaucomatous eyes (P≤0.012).Conclusions: ONH perfusion detected by OMAG showed significant differences between glaucoma and normal controls and was significantly correlated with disease severity and structural defects in glaucomatous eyes. ONH perfusion measurement using OMAG may provide useful information for detection and monitoring of glaucoma.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.