The objective of this study was to evaluate a new technique of sizing atrial septal defects (ASDs) for transcatheter device closure. ASD closure using the Amplatzer septal occluder (ASO) device is commonly performed. Complications, including arrhythmias, pericardial effusions, and perforations, may be related to oversizing ASDs and choosing larger devices. Two methods were used to size ASDs using a compliant balloon. In some patients, the balloon was inflated until a waist was visible [(+)waist]; in others, only until no shunting was demonstrable by echocardiogram [echo; (-)waist]. The device was selected and implanted using standard procedure and echo guidance. One hundred seventeen patients underwent secundum ASD closure with an ASO device. There were 43 patients in the (-)waist group and 74 in the (+)waist group. All devices were implanted successfully. The initial echo ASD diameter was larger in the (-)waist group compared to the (+)waist group (P = 0.01). There was a smaller difference between the initial echo and balloon-sized ASD diameters in the (-)waist group (P < 0.02). ASO device size implanted (in mm greater than echo ASD diameter) was smaller in the (-)waist group (P < 0.01). There were 0/43 complications in the (-)waist group and 5/74 in the (+)waist group. The complete closure rate was the same in both groups. Sizing an ASD by inflating a compliant balloon just until shunting is eliminated, and not until a waist is visible, results in less overstretching of the ASD and selection of a smaller ASO device, achieving similar closure rates and potentially fewer complications.
The American College of Cardiology Adult Congenital and Pediatric Cardiology (ACPC) Section had attempted to create quality metrics (QM) for ambulatory pediatric practice, but limited evidence made the process difficult. The ACPC sought to develop QMs for ambulatory pediatric cardiology practice. Five areas of interest were identified, and QMs were developed in a 2-step review process. In the first step, an expert panel, using the modified RAND-UCLA methodology, rated each QM for feasibility and validity. The second step sought input from ACPC Section members; final approval was by a vote of the ACPC Council. Work groups proposed a total of 44 QMs. Thirty-one metrics passed the RAND process and, after the open comment period, the ACPC council approved 18 metrics. The project resulted in successful development of QMs in ambulatory pediatric cardiology for a range of ambulatory domains.
Patients presenting beyond the neonatal period with left heart obstructive defects and intact atrial septum or restrictive ASD present a challenging problem. We report a safe and effective technique for relief of left atrial hypertension in infants using premounted intravascular stents. All patients had immediate marked hemodynamic improvement.
Mycotic aneurysms are rare in patients with congenital heart disease, but may occur in those with aortic coarctation and abnormal aortic valve. Rapid diagnosis of mycotic aneurysm is of extreme importance given the significant reported incidence of morbidity and mortality across all age groups. Aortic aneurysm is uncommon before the second decade of life, and here we report a 10-year-old male patient with new diagnosis of aortic coarctation and bicuspid aortic valve, who developed a rapidly enlarging mycotic aneurysm from Streptococcus pneumoniae. Cardiac magnetic resonance imaging was crucial in making the diagnosis, as well as in follow-up.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.