The relationship between intensity of inflammatory stimulation and production of α2-macroglobulin (α2M) and α1-acid glycoprotein (AAG) in rats was investigated. Sprague-Dawley rats were injected with turpentine oil at doses of 0.05, 0.2 or 0.4 mL/rat. Serum levels of α2M, interleukin (IL)-6 and cytokine-induced neutrophil chemoattractant-1 (CINC-1) were measured by enzyme-linked immunosorbent assay, and AAG was measured by single radial immunodiffusion. Peak serum levels of α2M and AAG in rats injected at 0.05 mL/rat were significantly lower than those at 0.2 or 0.4 mL/rat. However, no significant differences were observed for peak serum levels of these acute-phase proteins between 0.2 and 0.4 mL/rat. Furthermore, peak serum levels of IL-6 and CINC-1 in rats injected at 0.05 mL/rat were significantly lower than those at 0.2 or 0.4 mL/rat. Thus, the production of these acute-phase proteins has upper limits, even under increased strength of inflammatory stimulation in rats injected with turpentine oil.
A capillary reversed passive latex agglutination test (capillary RPLA) was developed which allows quantification of serum C-reactive protein (CRP) within approximately 15 min. The logarithmic regression line (calibration curve) obtained after measuring each CRP concentration three times in twofold dilutions of a standard canine serum containing 222 micrograms/ml of CRP was y = 6.394 + 0.030x (r = 0.995). Capillary RPLA permitted quantification of CRP in the range 6.9-222 micrograms/ml. The coefficients of variation ranged from 10.28% to 12.40%. The recovery rates (percentage recovery) of CRP by capillary RPLA were within the range 87% to 106%. On measuring the CRP concentrations in sera from 78 dogs by capillary RPLA, single radial immunodiffusion (SRID) and enzyme-linked immunosorbent assay (ELISA), close correlations were demonstrated between SRID and capillary RPLA (y = 7.250 + 1.109x, r = 0.978), between SRID and ELISA (y = 3.042 + 1.059x, r = 0.967), and between capillary RPLA and ELISA (y = 1.778 + 0.929x, r = 0.962). Capillary RPLA may be considered useful as a routine biochemical technique for measurement of serum CRP concentration in the dog.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.