We present the calibration and background model for the Large Area X-ray Proportional Counter (LAXPC) detectors on-board AstroSat. LAXPC instrument has three nominally identical detectors to achieve large collecting area. These detectors are independent of each other and in the event analysis mode, they record the arrival time and energy of each photon that is detected. The detectors have a time-resolution of 10 µs and a dead-time of about 42 µs. This makes LAXPC ideal for timing studies. The energy resolution and peak channel to energy mapping were obtained from calibration on ground using radioactive sources coupled with GEANT4 simulations of the detectors. The response matrix was further refined from observations of the Crab after launch. At around 20 keV the energy resolution of detector is 10-15%, while the combined effective area of the 3 detectors is about 6000 cm 2 .
The Canadian Penning Trap mass spectrometer has made mass measurements of 33 neutron-rich nuclides provided by the new Californium Rare Isotope Breeder Upgrade facility at Argonne National Laboratory. The studied region includes the 132Sn double shell closure and ranges in Z from In to Cs, with Sn isotopes measured out to A=135, and the typical measurement precision is at the 100 ppb level or better. The region encompasses a possible major waiting point of the astrophysical r process, and the impact of the masses on the r process is shown through a series of simulations. These first-ever simulations with direct mass information on this waiting point show significant increases in waiting time at Sn and Sb in comparison with commonly used mass models, demonstrating the inadequacy of existing models for accurate r-process calculations.
In the standard model, the weak interaction is formulated with a purely vector-axial-vector (V-A) structure. Without restriction on the chirality of the neutrino, the most general limits on tensor currents from nuclear β decay are dominated by a single measurement of the β-ν[over ¯] correlation in ^{6}He β decay dating back over a half century. In the present work, the β-ν[over ¯]-α correlation in the β decay of ^{8}Li and subsequent α-particle breakup of the ^{8}Be^{*} daughter was measured. The results are consistent with a purely V-A interaction and in the case of couplings to right-handed neutrinos (C_{T}=-C_{T}^{'}) limits the tensor fraction to |C_{T}/C_{A}|^{2}<0.011 (95.5% C.L.). The measurement confirms the ^{6}He result using a different nuclear system and employing modern ion-trapping techniques subject to different systematic uncertainties.
The Canadian Penning Trap mass spectrometer at the Californium Rare Isotope Breeder Upgrade (CARIBU) facility was used to measure the masses of eight neutron-rich isotopes of Nd and Sm. These measurements are the first to push into the region of nuclear masses relevant to the formation of the rare-earth abundance peak at A∼165 by the rapid neutron-capture process. We compare our results with theoretical predictions obtained from "reverse engineering" the mass surface that best reproduces the observed solar abundances in this region through a Markov chain Monte Carlo technique. Our measured masses are consistent with the reverse-engineering predictions for a neutron star merger wind scenario.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.