The question of whether influenza is transmitted to a significant degree by aerosols remains controversial, in part, because little is known about the quantity and size of potentially infectious airborne particles produced by people with influenza.
The International Organization for Standardization (ISO) standard 16900–1:2014 specifies the use of sodium chloride (NaCl) and corn oil aerosols, and sulfur hexafluoride gas for measuring total inward leakage (TIL). However, a comparison of TIL between different agents is lacking. The objective of this study was to measure and compare TIL for respirators using corn oil and NaCl aerosols. TIL was measured with 10 subjects donning two models of filtering facepiece respirators (FFRs) including FFP1, N95, P100, and elastomeric half-mask respirators (ERs) in NaCl and corn oil aerosol test chambers, using continuous sampling methods. After fit testing with a PortaCount (TSI, Inc., St. Paul, MN) using the Occupational Safety and Health Administration (OSHA) protocol, five subjects were tested in the NaCl chamber first and then in the corn oil chamber, while other subjects tested in the reverse order. TIL was measured as a ratio of mass-based aerosol concentrations in-mask to the test chamber, while the subjects performed ISO 16900–1-defined exercises. The concentration of NaCl aerosol was measured using two flame photometers, and corn oil aerosol was measured with one light scattering photometer. The same instruments were used to measure filter penetration in both chambers using a Plexiglas setup. The size distribution of aerosols was determined using a scanning mobility particle sizer and charge was measured with an electrometer. Filter efficiency was measured using an 8130 Automated Filter Tester (TSI). Results showed the geometric mean TIL for corn oil aerosol for one model each of all respirator categories, except P100, were significantly (p < 0.05) greater than for NaCl aerosol. Filter penetration in the two test chambers showed a trend similar to TIL. The count median diameter was ~ 82 nm for NaCl and ~ 200 nm for corn oil aerosols. The net positive charge for NaCl aerosol was relatively larger. Both fit factor and filter efficiency influence TIL measurement. Overall, TIL determination with aerosols of different size distributions and charges using different methodologies may produce dissimilar results.
The performance of field portable direct-reading organic vapor monitors (DROVMs) was evaluated under a variety of experimental conditions. Four of the DROVMs had photoionization detectors (ppbRAE, IAQRAE, MultiRAE, and Century Toxic Vapor Analyzer), one had a flame ionization detector (Century Toxic Vapor Analyzer), and one was a single-beam infrared spectrophotometer (SapphIRe). Four of each DROVM (two Century Toxic Vapor Analyzers and SapphIRes) were tested. The DROVMs were evaluated at three temperatures (4 degrees C, 21 degrees C, and 38 degrees C), three relative humidities (30%, 60%, and 90%), and two hexane concentrations (5 ppm and 100 ppm). These conditions were selected to provide a range within the operational parameters of all the instruments. At least four replicate trials were performed across the 18 experimental conditions (3 temperatures x 3 relative humidities x 2 concentrations). To evaluate performance, the 4-hr time-weighted average readings from the DROVMs in a given trial were compared with the average of two charcoal tube concentrations using pairwise comparison. The pairwise comparison criterion was +/-25% measurement agreement between each individual DROVM and the DROVMs as a group and the average charcoal tube concentration. The ppbRAE group performed the best with 40% of all readings meeting the comparison criterion followed by the SapphIRe group at 39%. Among individual DROVMs, the best performer was a SapphIRe, with 57% of its readings meeting the criterion. The data was further analyzed by temperature, humidity, and concentration. The results indicated the performance of some DROVMs may be affected by temperature, humidity, and/or concentration. The ppbRAE group performed best at 21 degrees C with the percentage of readings meeting the criterion increasing to 63%. At the 5 ppm concentration, 44% of the ppbRAE group readings met the criterion, while at 100 ppm, only 35% did. The results indicate that monitors can be used as survey tools. Based on the data, the inconsistent performance of these DROVMs may not allow them to be used for determining compliance with occupational exposure limits.
The physiological and subjective effects of working with different respirators while wearing lightweight disposable (Tyvek 1412 polyolefin) coveralls commonly used by the asbestos abatement industry were studied. Nine healthy men (mean age = 27.3 yr, weight = 76.9 kg) each performed a series of four exercise tests with four different respirator ensembles in counterbalanced order. Treadmill work was performed at a set walking speed of 4 kph (2.5 mph), 0 percent elevation (220 kcal/hr), a controlled environmental temperature of 33.9 degrees C, and 50% relative humidity. Each test continued up to 120 min, with repeated work/rest intervals of 26 min of work and 4 min of rest. Tyvek disposable coveralls and hoods were worn with each of these four different respirator ensembles: (1) control--a lightweight, low resistance mask; (2) HEPA--an air purifying, full facepiece respirator with dual high efficiency filters; (3) SAR--a supplied-air, pressure-demand respirator with escape filter; (4) SCBA--an open circuit, pressure-demand, self-contained breathing apparatus. Physiological measurements obtained every minute during each test included heart rate and skin and rectal temperatures. Subjective evaluations of clothing, respirator, and facepiece comfort, ease of breathing, temperature and perspiration in the mask and clothing, and respirator load also were measured at the end of the test. Data were analyzed using an analysis of variance. Results indicated that heart rate at the end of the test differed by less than 8 BPM between the control condition and the SCBA (heaviest) condition.(ABSTRACT TRUNCATED AT 250 WORDS)
This study describes a survey of environmental controls conducted by the National Institute for Occupational Safety and Health (NIOSH) at the Salvation Army Harbor Light Center homeless shelter in the City of St. Louis, Missouri. The Missouri Department of Health and Senior Services (MO DHHS) had epidemiologically linked 19 cases of active tuberculosis (TB) to the shelter. MO DHSS requested NIOSH to determine whether improvements could be made to the environmental controls to help reduce the probability of airborne transmission of TB at the shelter. NIOSH investigators conducted thorough inspections of the shelter's air-handling units (AHUs) and evaluated airflow rates. NIOSH recommended higher efficiency filters be used in the AHUs and installation of ultraviolet lights.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.