Abstract. The predominant driver of bioanalysis in supporting drug development is the intended use of the data. Ligand-binding assays (LBA) are widely used for the analysis of protein biotherapeutics and target ligands (L) to support pharmacokinetics/pharmacodynamics (PK/PD) and safety assessments. For monoclonal antibody drugs (mAb), in particular, which non-covalently bind to L, multiple forms of mAb and L can exist in vivo, including free mAb, free L, and mono-and/or bivalent complexes of mAb and L. Given the complexity of the dynamic binding equilibrium occurring in the body after dosing and multiple sources of perturbation of the equilibrium during bioanalysis, it is clear that ex vivo quantification of the forms of interest (free, bound, or total mAb and L) may differ from the actual ones in vivo. LBA reagents and assay formats can be designed in principle to measure the total or free forms of mAb and L. However, confirmation of the forms being measured under the specified conditions can be technically challenging. The assay forms and issues must be clearly communicated and understood appropriately by all stakeholders as the program proceeds through the development process. This paper focuses on monoclonal antibody biotherapeutics and their circulatory L that are either secreted as soluble forms or shed from membrane receptors. It presents an investigation into the theoretical and practical considerations for total/free analyte assessment to increase awareness in the scientific community and offer bioanalytical approaches to provide appropriate PK/PD information required at specific phases of drug development.
We report here the first radioimmunoassay for a vitamin D metabolite utilizing a radioiodinated tracer. Antibodies were generated in a goat immunized with the vitamin D analog 23, 24, 25, 26, 27-pentanor-C(22)-carboxylic acid of vitamin D, coupled directly with bovine serum albumin. The 125I-labeled tracer was prepared by reacting a 3-amino-propyl derivative of vitamin D-C(22)-amide with Bolton-Hunter reagent. The primary antiserum, used at a 15,000-fold final dilution, cross-reacted equally with all cholecalciferol and ergocalciferol metabolites tested except 1,25-dihydroxycalciferol metabolites and the parent calciferols; the antiserum did not cross-react with dihydrotachysterol. Calibrators were prepared in vitamin D-stripped human serum. 25-Hydroxycholecalciferol was quantitatively extracted from serum or plasma (50 microL) with acetonitrile. The assay consists of a 90-min incubation at room temperature with primary antiserum, followed by a 20-min incubation with a second antiserum and separation of bound from free fractions by centrifugation. The detection limit of the assay was 2.8 micrograms/L for 25-hydroxycholecalciferol. Results with the present assay compared well with those from a liquid-chromatographic procedure involving specific ultraviolet detection of 25-hydroxycalciferol in plasma.
The 2015 9th Workshop on Recent Issues in Bioanalysis (9th WRIB) took place in Miami, Florida with participation of 600 professionals from pharmaceutical and biopharmaceutical companies, biotechnology companies, contract research organizations and regulatory agencies worldwide. WRIB was once again a 5 day, week-long event - A Full Immersion Bioanalytical Week - specifically designed to facilitate sharing, reviewing, discussing and agreeing on approaches to address the most current issues of interest in bioanalysis. The topics covered included both small and large molecules, and involved LCMS, hybrid LBA/LCMS and LBA approaches, including the focus on biomarkers and immunogenicity. This 2015 White Paper encompasses recommendations emerging from the extensive discussions held during the workshop, and is aimed to provide the bioanalytical community with key information and practical solutions on topics and issues addressed, in an effort to enable advances in scientific excellence, improved quality and better regulatory compliance. Due to its length, the 2015 edition of this comprehensive White Paper has been divided into three parts. Part 3 discusses the recommendations for large molecule bioanalysis using LBA, biomarkers and immunogenicity. Part 1 (small molecule bioanalysis using LCMS) and Part 2 (hybrid LBA/LCMS and regulatory inputs from major global health authorities) have been published in volume 7, issues 22 and 23 of Bioanalysis, respectively.
The 2016 10th Workshop on Recent Issues in Bioanalysis (10th WRIB) took place in Orlando, Florida with participation of close to 700 professionals from pharmaceutical/biopharmaceutical companies, biotechnology companies, contract research organizations, and regulatory agencies worldwide. WRIB was once again a weeklong event - A Full Immersion Week of Bioanalysis for PK, Biomarkers and Immunogenicity. As usual, it is specifically designed to facilitate sharing, reviewing, discussing and agreeing on approaches to address the most current issues of interest including both small and large molecules involving LCMS, hybrid LBA/LCMS, and LBA approaches, with the focus on PK, biomarkers and immunogenicity. This 2016 White Paper encompasses recommendations emerging from the extensive discussions held during the workshop, and is aimed to provide the bioanalytical community with key information and practical solutions on topics and issues addressed, in an effort to enable advances in scientific excellence, improved quality and better regulatory compliance. This White Paper is published in 3 parts due to length. This part (Part 3) discusses the recommendations for large molecule bioanalysis using LBA, biomarkers and immunogenicity. Parts 1 (small molecule bioanalysis using LCMS) and Part 2 (Hybrid LBA/LCMS and regulatory inputs from major global health authorities) have been published in the Bioanalysis journal, issues 22 and 23, respectively.
"The Global CRO Council (GCC) for Bioanalysis was formed in an effort to bring together many CRO leaders to openly discuss bioanalysis and the regulatory challenges unique to the outsourcing industry"
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations –citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.