Purpose: To analyze the 2-year outcomes of endovascular aneurysm sealing (EVAS) according to 2 versions of the instructions for use (IFU). Methods: A retrospective study was conducted involving 355 consecutive patients treated with the first-generation EVAS device from April 2013 to December 31, 2015, at 3 high-volume centers. Out of 355 patients treated with EVAS, 264 were elective asymptomatic infrarenal EVAS procedures suitable for analysis. In this cohort, 168 (63.3%) patients were treated within the IFU 2013 criteria; of these 48 (18.2%) were in compliance with the revised IFU 2016 version. Results: Overall technical success was 98.2% (165/168) in the IFU 2013 group and 97.9% (47/48) in the IFU 2016 subgroup (p=0.428). The 2-year freedom from reintervention estimates were 89.7% (IFU 2013) and 95.7% (IFU 2016), with significantly more reinterventions in the first 45 cases (p=0.005). The stenosis/occlusion estimates were 6.5% (IFU 2013) and 4.2% (IFU 2016; p=0.705). Nine (5.4%) endoleaks (8 type Ia and 1 type Ib) were observed within the IFU 2013 cohort; 3 (2.1%) were in the IFU 2016 subgroup (p=0.583). Migration ≥10 mm or ≥5 mm requiring intervention was reported in 12 (7.1%) patients in the IFU 2013 cohort but none within the IFU 2016 subgroup. Ten (6.0%) patients demonstrated aneurysm growth in the IFU 2013 cohort, of which 2 (4.2%) were in the IFU 2016 subgroup. Overall survival and freedom from aneurysm-related death estimates at 2 years were 90.9% and 97.6% in the IFU 2013 cohort (IFU 2016: 95.5% and 100.0%). The prevalence of complications seemed lower within IFU 2016 without significant differences. Conclusion: This study shows acceptable 2-year results of EVAS used within the IFU, without significant differences between the 2 IFU versions, though longer follow-up is indicated. The refined IFU significantly reduced the applicability of the technique.
The studied aortoiliac stent configurations have distinct locations where flow disturbances occur, and these are related to the radial mismatch. The CERAB configuration is the most unimpaired physiologic reconstruction, whereas BMK and CK stents have their typical zones of flow recirculation.
The proposed gutter classification enables a uniform nomenclature in the current ch-EVAR literature and a more accurate risk assessment of gutter-associated endoleaks. Moreover, it allows monitoring of eventual progression of gutter size during follow-up.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.