Adenovirus is recognized as the most UV-resistant waterborne pathogen of concern to public health microbiologists. The U.S. EPA has stipulated that a UV fluence (dose) of 186 mJ cm ؊2 is required for 4-log inactivation credit in water treatment. However, all adenovirus inactivation data to date published in the peer-reviewed literature have been based on UV disinfection experiments using UV irradiation at 253.7 nm produced from a conventional low-pressure UV source. The work reported here presents inactivation data for adenovirus based on polychromatic UV sources and details the significant enhancement in inactivation achieved using these polychromatic sources. When full-spectrum, medium-pressure UV lamps were used, 4-log inactivation of adenovirus type 40 is achieved at a UV fluence of less than 60 mJ cm ؊2 and a surface discharge pulsed UV source required a UV fluence of less than 40 mJ cm ؊2 . The action spectrum for adenovirus type 2 was also developed and partially explains the improved inactivation based on enhancements at wavelengths below 230 nm. Implications for water treatment, public health, and the future of UV regulations for virus disinfection are discussed.UV disinfection is a well-accepted technology for inactivation of bacterial and protozoan pathogens. Until recently, UV was also considered a viable technology for disinfection of viruses. At UV fluences (doses) typically used in water disinfection, UV is very effective (Ͼ4-log inactivation) against almost all known pathogenic viruses, with the one exception of adenoviruses (5). Adenovirus has been recently listed on the U.S. EPA Candidate Contaminant List, which indicates that it is a high priority for possible future regulation and is known or anticipated to occur in public water systems, but significant data gaps need to be addressed before regulation can be invoked. According to recently published U.S. EPA regulations (17), the inactivation of adenoviruses to a level of 4 log requires a UV fluence of 186 mJ cm Ϫ2 , based on an 80% credible interval, as presented in the Draft UV Disinfection Guidance Manual (16). The U.S. EPA-regulated UV fluence for inactivation of all viruses is now based on the conservative case of adenoviruses. Yates et al. (18) provide an excellent review of the issues surrounding the UV inactivation of adenovirus.Although data sets for UV inactivation of adenovirus differ moderately, they all place adenovirus as the most UV-resistant health-related virus known. However, all peer-reviewed published studies to date have been performed using a low-pressure (LP) mercury vapor UV lamp source characterized by a monochromatic output in the UV range at 253.7 nm. Based on these LP UV irradiation studies, the UV fluence necessary to achieve 4-log inactivation of adenovirus varies from 120 to approximately 180 mJ cm Ϫ2 . For adenovirus type 5 (Ad5), the required UV fluence is 160 to 170 mJ cm Ϫ2 (1), which is similar to those required for Ad1 (9), Ad2 (1, 5), Ad6 (9), and Ad40 and Ad41 (8). However, there are two studies that repo...
Information on the required chlorine dose or Ct value (concentration of free chlorine multiplied by contact time) is limited to only a few enteroviruses. In this study the Ct values of some of the reported more chlorine resistant enteroviruses were determined. The Efficiency Hom Model was used to predict the times for 2, 3. and 4 -log inactivation of echovirus 1 and 12, coxsackievirus B5 and poliovirus type 1 at pH 7.5 and 9 at 5 degrees C. Coxsackievirus B5 was the most resistant to chlorine with a Ct requirement of 11.5 mg x min/L at pH 7.5 at 5 degrees C compared to polio with a Ct of 5.3 mg x min/L under the same conditions. All the viruses were more resistant than polio 1 at pH 9.0.
The enhancement of water quality by artificial wetland systems is increasingly being employed throughout the world. Three wetlands were studied in Tucson, AZ to evaluate their individual performance in the removal of indicator bacteria (coliforms), coliphage, and enteric pathogens (Giardia and Cryptosporidium). A duckweed-covered pond, a multi-species subsurface flow (SSF) and a multi-species surface flow (SF) wetland were studied. Removal of the larger microorganisms, Giardia and Cryptosporidium, was the greatest in the duckweed pond at 98 and 89 percent, respectively. The lowest removal occurred in the SF wetland, 73 percent for Giardia and 58 percent removal for Cryptosporidium. In contrast, the greatest removal of coliphage, total and fecal coliforms occurred in the SSF wetland, 95, 99, and 98 percent respectively, whereas the pond had the lowest removals (40, 62, and 61 percent, respectively). Sedimentation may be the primary removal mechanism within the duckweed pond since the removal was related to size, removal of the largest organisms being the greatest. However, the smaller microorganisms were removed more efficiently in the SSF wetland, which may be related to the large surface area available for adsorption and filtration. This study suggests that in order to achieve the highest treatment level of secondary unchlorinated wastewater, a combination of aquatic ponds and subsurface flow wetlands may be necessary.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.