The Canadian Cardiovascular Society (CCS) atrial fibrillation (AF) guidelines program was developed to aid clinicians in the management of these complex patients, as well as to provide direction to policy makers and health care systems regarding related issues. The most recent comprehensive CCS AF guidelines update was published R ESUM ELe programme de lignes directrices de la Soci et e canadienne de cardiologie (SCC) en matière de fibrillation auriculaire (FA) a et e elabor e pour aider les cliniciens à prendre en charge ces patients complexes, ainsi que pour orienter les d ecideurs politiques et les systèmes de soins de sant e sur des questions connexes. La dernière edition
Background: Advanced generation ablation technologies have been developed to achieve more effective pulmonary vein isolation (PVI) and minimize arrhythmia recurrence after atrial fibrillation (AF) ablation. Methods: We randomly assigned 346 patients with drug-refractory paroxysmal AF to contact force–guided radiofrequency ablation (CF-RF; n=115), 4-minute cryoballoon ablation (Cryo-4; n=115), or 2-minute cryoballoon ablation (Cryo-2; n=116). Follow-up was 12 months. The primary outcome was time to first documented recurrence of symptomatic or asymptomatic atrial tachyarrhythmia (AF, atrial flutter, or atrial tachycardia) between days 91 and 365 after ablation or a repeat ablation procedure at any time. Secondary end points included freedom from symptomatic arrhythmia and AF burden. All patients received an implantable loop recorder. Results: One-year freedom from atrial tachyarrhythmia defined by continuous rhythm monitoring was 53.9%, 52.2%, and 51.7% with CF-RF, Cryo-4, and Cryo-2, respectively ( P =0.87). One-year freedom from symptomatic atrial tachyarrhythmia defined by continuous rhythm monitoring was 79.1%, 78.2%, and 73.3% with CF-RF, Cryo-4, and Cryo-2, respectively ( P =0.26). Compared with the monitoring period before ablation, AF burden was reduced by a median of 99.3% (interquartile range, 67.8%–100.0%) with CF-RF, 99.9% (interquartile range, 65.3%–100.0%) with Cryo-4, and 98.4% (interquartile range, 56.2%–100.0%) with Cryo-2 ( P =0.36). Serious adverse events occurred in 3 patients (2.6%) in the CF-RF group, 6 patients (5.3%) in the Cryo-4 group, and 7 patients (6.0%) in the Cryo-2 group, with no significant difference between groups ( P =0.24). The CF-RF group had a significantly longer procedure duration but significantly shorter fluoroscopy exposure ( P <0.001 vs cryoballoon groups). Conclusions: In this multicenter, randomized, single-blinded trial, CF-RF and 2 different regimens of cryoballoon ablation resulted in no difference in 1-year efficacy, which was 53% by time to first recurrence but >98% burden reduction as assessed by continuous cardiac rhythm monitoring. Clinical Trial Registration: URL: https://www.clinicaltrials.gov . Unique identifier: NCT01913522.
Background/purpose : Interventional cardiac electrophysiology (EP) is a rapidly evolving field in Canada; a nationwide registry was established in 2011 to conduct a periodic review of resource allocation. Methods The registry collects annual data on EP lab infrastructure, imaging, tools, human resources, procedural volumes, success rates, and wait times. Leading physicians from each EP lab were contacted electronically; participation was voluntary. Results All Canadian EP centres were identified (n = 30); 50 and 45 % of active centres participated in the last 2 instalments of the registry. A mean of 508 ± 270 standard and complex catheter ablation procedures were reported annually for 2015–2016 by all responding centres. The most frequently performed ablation targets atrial fibrillation (PVI) arrhythmia accounting for 36 % of all procedures (mean = 164 ± 85). The number of full time physicians ranges between 1 and 7 per centre, (mean = 4). The mean wait time to see an electrophysiologist for an initial non-urgent consult is 23 weeks. The wait time between an EP consult and ablation date is 17.8 weeks for simple ablation, and 30.1 weeks for AF ablation. On average centres have 2 (range: 1–4) rooms equipped for ablations; each centre uses the EP lab an average of 7 shifts per week. While diagnostic studies and radiofrequency ablations are performed in all centres, point-by-point cryoablation is available in 85 % centres; 38 % of the respondents use circular ablation techniques. Conclusions This initiative provides contemporary data on invasive electrophysiology lab practices. The EP registry provides activity benchmarks on national trends and practices.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.