An increased systemic and local inflammation plays a key role in the pathophysiology of acute coronary syndrome (ACS). This review will discuss the role of hematological indices: white blood cells (WBC), neutrophil to lymphocyte ratio (NLR), red cell distribution width (RDW), and platelet indices, that is, platelet to lymphocyte ratio (PLR), mean platelet volume (MPV), and platelet distribution width (PDW) in the case of ACS. In recent years, a strong interest has been drawn to these indices, given that they may provide independent information on pathophysiology, risk stratification, and optimal management. Their low-cost and consequent wide and easy availability in daily clinical practice have made them very popular in the laboratory testing. Furthermore, many studies have pointed at their effective prognostic value in all-cause mortality, major cardiovascular events, stent thrombosis, arrhythmias, and myocardial perfusion disorders in terms of acute myocardial infarction and unstable angina. The most recent research also emphasizes their significant value in the combined analysis with other markers, such as troponin, or with GRACE, SYNTAX, and TIMI scores, which improve risk stratification and diagnosis in ACS patients.
Inflammation, oxidative stress, myocardial injury biomarkers and clinical parameters (longer AF duration, left atrial enlargement, the metabolic syndrome) are factors commonly related to AF recurrence. This study aims to assess the predictive value of laboratory and clinical parameters responsible for early recurrence of atrial fibrillation (ERAF) following cryoballoon ablation (CBA) using statistical assessment and machine learning algorithms. This study group comprised 118 consecutive patients (mean age, 62.5 ± 7.8 years; women 36%) with paroxysmal (54.1%) and persistent (45.9%) AF who underwent their first pulmonary vein isolation (PVI) performed by CBA (Arctic Front Advance 2nd generation 28 mm). The biomarker concentrations were measured at baseline and after CBA in a 24-h follow-up. ERAF was defined as at least a 30-s episode of arrhythmia registered by a 24 h-Holter monitor within the 3 months following the procedure. 56 clinical, laboratory and procedural variables were collected from each patient. We used two classification algorithms: support vector machines, gradient boosted tree. The synthetic minority over-sampling technique (SMOTE) was used to provide a balanced training data set. Within a period of 3 months 21 patients (17.8%) experienced ERAF. The statistical analysis indicated that the lowered levels of post-ablation TnT (p = 0.043) and CK-MB (p = 0.010) with the TnT elevation (p = 0.044) were the predictors of ERAF following CBA. In addition, diabetes and statin treatment were significantly associated with ERAF after CBA (p < 0.05). The machine learning algorithms confirmed the results obtained in the univariate analysis.
Introduction. Hematological indices including red cell distribution width and neutrophil to lymphocyte ratio are proven to be associated with outcomes of acute coronary syndrome. The usefulness of machine learning techniques in predicting mortality after acute coronary syndrome based on such features has not been studied before. Objective. We aim to create an alternative risk assessment tool, which is based on easily obtainable features, including hematological indices and inflammation markers. Patients and Methods. We obtained the study data from the electronic medical records of 5053 patients hospitalized with acute coronary syndrome during a 5-year period. The time of follow-up ranged from 12 to 72 months. A machine learning classifier was trained to predict death during hospitalization and within 180 and 365 days from admission. Our method was compared with the Global Registry of Acute Coronary Events (GRACE) Score 2.0 on a test dataset. Results. For in-hospital mortality, our model achieved a c-statistic of 0.89 while the GRACE score 2.0 achieved 0.90. For six-month mortality, the results of our model and the GRACE score on the test set were 0.77 and 0.73, respectively. Red cell distribution width (HR 1.23; 95% CL 1.16-1.30; P<0.001) and neutrophil to lymphocyte ratio (HR 1.08; 95% CL 1.05-1.10; P<0.001) showed independent association with all-cause mortality in multivariable Cox regression. Conclusions. Hematological markers, such as neutrophil count and red cell distribution width have a strong association with all-cause mortality after acute coronary syndrome. A machine-learned model which uses the abovementioned parameters can provide long-term predictions of accuracy comparable or superior to well-validated risk scores.
Objectives: The purpose of the present study was to evaluate the efficacy and safety of a biodegradable polymer coated, paclitaxel eluting stent (Luc-Chopin 2 ) based on 9-months angiographic and 12-months clinical follow-up results. Background: First-generation drug-eluting stents utilize nonbioabsorbable polymeric coatings, whose persistent presence in the arterial wall may negatively affect long-term outcomes. Bioabsorbable coatings with a degradation period matched to that of the drug elution may be a better alternative, clinically and economically. Methods: We conducted a prospective, multicenter first-in-man registry of a novel, locally developed, bioabsorbable-coated, paclitaxel-eluting coronary stent in 116 patients with single-lesion de novo coronary disease. Results: Major adverse cardiac events occurred in 7.8% patients within 12 months. There were no late thrombotic events, death, stroke, or surgical revascularization in that period. There were two myocardial infarctions, one related to recent subacute stent thrombosis and another associated with restenosis. By 12 months, target vessel revascularization was performed in 7.8%; 2.9% were ischemia-driven and the rest were mandated at 9 months in accordance with a control angiography protocol. Core-lab assessed binary in-stent restenosis (≥50% DS) was noted in 11.9% patients and mean late loss was 0.46 6 0.47 mm. Conclusions: This first-in-man experience obtained in a multicenter registry of real-world de novo lesions (almost half of lesions were class B2 or C by AHA classification) showed a favorable safety profile and acceptable efficacy through 12 months. Randomized comparison with a benchmark nonbioabsorbable polymer coated paclitaxel eluting stent should be undertaken to validate this initial positive experience. '
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.