Aims To critically review the available transcatheter aortic valve implantation techniques and their results, as well as propose recommendations for their use and development. Methods and results A committee of experts including European Association of Cardio-Thoracic Surgery and European Society of Car-diology representatives met to reach a consensus based on the analysis of the available data obtained with transcath-eter aortic valve implantation and their own experience. The evidence suggests that this technique is feasible and provides haemodynamic and clinical improvement for up to 2 years in patients with severe symptomatic aortic ste-nosis at high risk or with contraindications for surgery. Questions remain mainly concerning safety and long-term durability, which have to be assessed. Surgeons and cardiologists working as a team should select candidates, perform the procedure, and assess the results. Today, the use of this technique should be restricted to high-risk patients or those with contraindications for surgery. However, this may be extended to lower risk patients if the initial promise holds to be true after careful evaluation. * Corresponding authors. Tel: þ33 1 40 25 67 60, Fax: þ33 1 40 25 67 32, Email: alec.vahanian@bch.aphp.fr (A. V.);
Midterm to long-term survival after TAVI was encouraging in this high-risk patient population, although a substantial proportion of patients died within the first year.
Paravalvular aortic regurgitation (PAR) negatively affects the prognosis after transcatheter aortic valve replacement (TAVR) with dramatically increased morbidity and mortality in patients with more than mild PAR. Because transcatheter heart valves are implanted in a sutureless fashion using oversizing to anchor the prosthesis stent frame at the level of the virtual aortic annulus, stent frame underexpansion due to heavily calcified cusps, suboptimal placement of the prosthesis, and/or annulus-prosthesis-size mismatch due to malsizing can contribute to paravalvular leakage. In contrast to open heart surgery, TAVR does not offer the opportunity to measure the aortic annulus under direct vision during the procedure. Therefore, the dilemma before each TAVR procedure is the appropriate sizing of the dimensions of the aortic annulus and to choose not only the size but also the transcatheter heart valve type (self-expanding vs. balloon-expandable) that fits the given anatomy best. Because precise echocardiographic quantification of PAR in patients with TAVR remains challenging especially in the acute implantation situation, a multimodal approach for the evaluation of PAR with the use of hemodynamic measurements and imaging modalities is imperative to precisely quantify the severity of aortic regurgitation immediately after valve implantation and to identify patients who will benefit from corrective measures such as post-dilation or valve-in-valve implantation. Every measure has to be taken to prevent or reduce PAR to provide a satisfying long-term clinical outcome.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.