Objective The aim of this study was to compare the locking compression plate (LCP) with polyaxial locking system (PLS) using single cycle to failure 4-point bending test and to investigate the behaviour of PLS with screws inserted mono- and polyaxially using cyclic fatigue test in two bending directions. Materials and Methods Tests were performed on bone surrogates in a fracture gap model. The 3.5 LCP and 3.5 PLS plates were tested in single cycle to failure. The 3.5 PLS plates with mono- and polyaxial screws were compared in a cyclic fatigue tests in two orthogonal directions. For both experiments, micro-computed tomography (CT) scans were performed pre- and post-testing to investigate the connections between the screw head and the plate hole. Means of forces and cycles needed to failure were statistically compared. Results The PLS plates were on average 30% weaker than LCP plates. Mode of failure was plate bending in the single cycle to failure tests, and plate breakage in the cyclic fatigue tests. Neither screw breakage nor loss of the screw–plate interface occurred. Mono- and polyaxial constructs performed similarly when loaded in the same direction. Micro-CT revealed no additional internal cracks in the plates or screws after testing. It also showed for both PLS and LCP that there was only partial contact of the screw head with the plate hole. Clinical Relevance PLS offers a durable locking system, even when the screws are placed polyaxially. The weaker bending properties of the PLS compared with LCP should be considered during preoperative planning.
Objective The aim of this study was to evaluate the effect of screw insertion angle and insertion torque on the mechanical properties of a 3.5 fixed-angle locking plate locking compression plate (LCP) and 3.5 variable-angle locking plate polyaxial locking system (PLS). Methods In the LCP group, screws were placed abaxially at 0, 5 and 10 degrees. In the PLS group, screws were placed at 0, 5, 10, 15 and 20 degrees abaxially. The insertion torque was set to 1.5 and 2.5 Nm in the LCP and PLS groups respectively. A load was applied parallel to the screw axis, and the screw push-out force was measured until the locking mechanism was loosened. Results The 3.5 LCP showed higher push-out strength than the 3.5 PLS when the screws were placed at 0 degree regardless of the insertion torque. The off-axis insertion of 3.5 LCP locking screws resulted in a significant decrease in push-out strength (p < 0.05). A higher insertion torque value significantly increased the screw holding strength for the 3.5 LCP (p < 0.05). The 3.5 PLS system had a significantly higher push-out force when the screws are at 0 degree than at 5, 10 and 15 degrees, and 20 degrees (p < 0.05) at any given insertion torque. An increase in the insertion torque did not have a significant effect on the push-out strength of the 3.5 PLS locking system. Conclusion The 3.5 PLS is more sensitive to the screw insertion angle than to the insertion torque, whereas the 3.5 LCP is affected by both factors. Placing 3.5 LCP locking screws off-axis significantly reduces the screw holding strength; therefore, this approach has to be avoided. The findings of our research indicate that a 1.5 Nm torque can be used for a 3.5 PLS.
Objective: To report radiographic findings and complications after fracture repair with a new polyaxial locking plate system (PLS polyaxial locking system; Aesculap/B Braun, Tuttlingen, Germany) in dogs and cats. Study design: Retrospective case review from four veterinary practices. Sample population: Twenty-six dogs and 14 cats (40 long bone fractures). Methods: Medical and radiographic records of dogs and cats with long bone fractures treated with the PLS were reviewed. Cases were included when operative records were complete and included documentation of radiographic union or complications. Phone interviews of owners were performed for longterm follow-up. Ancillary methods of fracture fixation and associated complications were recorded. Results: Only two complications were recorded, one of which required a revision surgery. Radiographic follow-up was performed for all fractures. Radiographic union without complications was achieved in 38 of 40 (95%) fractures. Radiographic union was documented before 60 days in 19 of 40 (47.5%) fractures, between 61 and 90 days in 15 of 40 (37.5%) fractures, and after 90 days in six of 40 (15%) fractures. A functional union was observed at a mean time ± SD of 70.8 ± 38.9 days (range, 32-182). One or more ancillary fixation methods were used in 27 of 40 (67.5%) fractures. Conclusion: The PLS polyaxial locking system was often used with adjunct fixation in this series, and radiographically confirmed healing without complications was documented in most cases. Clinical significance: Use of the PLS can result in high success rates for fracture repair in dogs and cats, but ancillary fixation should be strongly considered.
The detection and measurement of hydrocarbons is of high interest for a variety of applications, for example within the oil & gas industry from extraction throughout the complete refining process, as well as for environmental monitoring and for portable safety devices. This paper presents a highly sensitive, selective and robust tunable laser analyzer that has the capability to analyze several components in a gas sample stream. More specifically, a multi-gas system for simultaneous detection of C1 to iC5 hydrocarbons, using a room temperature distributed feedback interband cascade laser array, emitting in the 3.3 micrometer band has been realized. It combines all the advantages of the tunable laser spectroscopy method for a fast, sensitive and selective in-line multicomponent tunable laser analyzer. Capable of continuous and milliseconds fast monitoring of C1-iC5 hydrocarbon compositions in a process stream, the analyzer requires no consumables (e.g. purging, carrier gas) and no in-field calibration, enabling a low cost of ownership for the analyzer. The system was built, based on an industrial GasEye series platform and deployed for the first time in field at Preem refinery in Lysekil, Sweden in autumn 2018. Results of the measurement campaign and comparison with gas chromatography instrumentation is presented.
Objective To quantify the amount of the screw head thread and the plate hole thread connection in two 3.5 mm locking plates: Locking Compression Plate (LCP) and Polyaxial Locking System (PLS). Materials and Methods A micro - CT scan of a screw head - plate hole connection was performed pre- and post destructive tests. Tests were performed on bone surrogates in a fracture gap model. The 3.5 LCP and 3.5 PLS plates, with 3 perpendicular screws per segment were used in a destructive static test. The 3.5 PLS plates with mono- and polyaxial screws were compared in a cyclic fatigue tests in two orthogonal directions. Pre - and post - test scan datasets were compared. Each dataset was converted into serial images depicting sections cut orthogonally to locking screw axis. The amount of engagement was detected through automated image postprocessing. Results The mean amount of the thread connection for the LCP was 28.85% before and 18.55% after destructive static test. The mean amount of the connection for the PLS was 16.20% before and 14.55% after destructive static test. When inserted monoaxially, the mean amount of the connection for the PLS screws was 14.4% before and 19.24% after destructive cyclic test. The mean amount of the connection for the polyaxial inserted PLS screws when loaded against plate thickness was 2.99% before and 2.08% after destructive cyclic test. The mean amount of the connection for the polyaxial inserted PLS screws when loaded against plate width was 3.36% before and 3.93% after destructive cyclic test. The 3D visualization of the thread connection showed that the initial interface points between screw head and plate hole are different for both LCP and PLS after the destructive testing. Depending on the type of applied force, there was either loss or increase of the contact. Clinical Relevance Micro-CT offers news possibilities in locking implant investigation. It might be helpful in better understanding the nature of locking mechanism and prediction of possible mode of failure in different systems.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.