MiR-148a sensitized chemotherapy-sensitive oesophageal cancer cell lines to cisplatin and, to a lesser extent, to 5-flurouracil and attenuated resistance in chemotherapy-resistant variants. Further experimental and clinical studies to investigate the exact mechanisms involved are warranted.
Objective: Nondiagnostic cytology is the most important limitation of thyroid ultrasound-guided fine-needle aspiration (US-FNA). This study aimed to identify factors associated with the adequacy rate of thyroid US-FNA. Study Design: Consecutive thyroid US-FNAs (2006-2013) were retrospectively included. Attending radiologists, radiology fellows and radiology residents performed US-FNA, usually involving 2-3 needle passes. In more recent years, rapid on-site adequacy assessment (ROSAA) was performed to ensure specimen adequacy. US characteristics, procedural variations and cytology results were extracted from US and pathology reports and statistically evaluated. Results: Diagnostic cytology was obtained in 64.6% of 1,381 thyroid US-FNAs. Factors associated with nondiagnostic cytology were ROSAA (74.6% diagnostic cytology, OR 0.55, 95% CI 0.42-0.71), ≥3 clinic visits for US-FNA of the same thyroid nodule (54.7%, OR 1.56, 95% CI 1.16-2.10) and increased intranodular vascularization (51.8%, OR 1.73, 95% CI 1.17-2.57). With ROSAA, an increasing number of needle passes demonstrated improving adequacy rates. The adequacy rate was not operator-dependent. Conclusion: This study demonstrates that ROSAA improves the adequacy rate of thyroid US-FNA. Without ROSAA, we recommend performing at least 3 needle passes. Less diagnostic cytology is obtained from nodules with increased intranodular vascularization or from those undergoing US-FNA ≥3 times.
Thyroid cancer is the most common endocrine neoplasm accounting for approximately 1,7% of total cancer diagnoses. The gold standard for evaluation of thyroid nodules is cytology from fine needle aspiration. In 30% of biopsies there is no conclusive diagnosis and patients undergo a diagnostic hemithyroidectomy. Somatic mutations occur frequently in thyroid cancer, the value of testing FNA biopsies on different mutation is analyzed, it improves accuracy, but their sensitivity is low. Another class of molecules with potential diagnostic value are miRNAs (miRNA, miR). MiRNAs function as gene regulators thereby controlling many cellular processes including cell growth, differentiation, proliferation, and apoptosis. Several studies have analyzed the expression of miRNAs in thyroid cancer, either by performing microarray analyses or validating a set of miRNAs. Recent reports focused on the diagnostic value of miRNAs in indeterminate FNA biopsies. In this systematic review we will provide an overview of all miRNAs found to be up- or downregulated in the different types of thyroid carcinomas, give an overview of the value of validated sets of microRNAs or single microRNAs in distinguishing malignant from benign lesions and conclude with a clinical view on future study strategies.
PurposeThere has been an increased utilization of the posterior retroperitoneal approach (PRA) for adrenalectomy alongside the “classic” laparoscopic transabdominal technique (LTA). The aim of this study was to compare both procedures based on outcome variables at various ranges of tumor size.MethodsA retrospective analysis was performed on 204 laparoscopic transabdominal (UMC Groningen) and 57 retroperitoneal (UMC Utrecht) adrenalectomies between 1998 and 2013. We applied a univariate and multivariate regression analysis. Mann-Whitney and chi-squared tests were used to compare outcome variables between both approaches.ResultsBoth mean operation time and median blood loss were significantly lower in the PRA group with 102.1 (SD 33.5) vs. 173.3 (SD 59.1) minutes (p < 0.001) and 0 (0–200) vs. 50 (0–1000) milliliters (p < 0.001), respectively. The shorter operation time in PRA was independent of tumor size. Complication rates were higher in the LTA (19.1%) compared to PRA (8.8%). There was no significant difference in recovery time between both approaches.ConclusionsApplication of the PRA decreases operation time, blood loss, and complication rates compared to LTA. This might encourage institutions that use the LTA to start using PRA in patients with adrenal tumors, independent of tumor size.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.