Background
Total hip replacement has recently followed a progressive evolution towards principles of bone- and soft-tissue-sparing surgery. Regarding femoral implants, different stem designs have been developed as an alternative to conventional stems, and there is a renewed interest towards short versions of uncemented femoral implants. Based on both experimental testing and finite element modeling, the proposed study has been designed to compare the biomechanical properties and clinical performance of the newly introduced short-stem Minima S, for which clinical data are lacking with an older generation stem, the Trilock Bone Preservation Stem with an established performance record in short to midterm follow-up.
Methods/design
In the experimental study, the transmission of forces as measured by cortical surface-strain distribution in the proximal femur will be evaluated using digital image correlation (DIC), first on the non-implanted femur and then on the implanted stems. Finite element parametric models of the bone, the stem and their interface will be also developed. Finite element predictions of surface strains in implanted composite femurs, after being validated against biomechanical testing measurements, will be used to assist the comparison of the stems by deriving important data on the developed stress and strain fields, which cannot be measured through biomechanical testing. Finally, a prospective randomized comparative clinical study between these two stems will be also conducted to determine (1) their clinical performance up to 2 years’ follow-up using clinical scores and gait analysis (2) stem fixation and remodeling using a detailed radiographic analysis and (3) incidence and types of complications.
Discussion
Our study would be the first that compares not only the clinical and radiological outcome but also the biomechanical properties of two differently designed femoral implants that are theoretically classified in the same main category of cervico-metaphyseal-diaphyseal short stems. We can hypothesize that even these subtle variations in geometric design between these two stems may create different loading characteristics and thus dissimilar biomechanical behaviors, which in turn could have an influence to their clinical performance.
Trial registration
International Standard Randomized Controlled Trial Number, ID:
ISRCTN10096716
. Retrospectively registered on May 8 2018.
Electronic supplementary material
The online version of this article (10.1186/s13063-019-3445-x) contains supplementary material, which is available to authorized users.
Progressive damage modeling (PDM) is a well-established methodology for the prediction of damage initiation and evolution in composite structures. However, as conventional PDM methodology involves a large post-processing procedure, it is impractical for application in large-scale structures due to the high computational cost it requires. In this study, the local character of nonlinearity, due to the scale of the damage topology compared to the size of the entire structure, is exploited to propose proper modifications in the 'classical' PDM methodology. Specifically, the sub-modeling technique principles are combined and integrated in the PDM methodology and the appropriate modifications required are discussed. Furthermore, two damage prediction indices, which are related to the criticality of damage state at specific sub-areas (material layers) of the structure are introduced, in order to achieve significant reductions of the required computational time. Both the improvements make the application of PDM in large-scale composite structures practically feasible; this is demonstrated in the case of a generic composite shear joint whose numerical model comprises over a million degrees of freedom.
A multifield simulation approach of cellular cores produced by additive manufacturing is presented. The analysis is aiming to derive the relation between the manufacturing process parameters and the resulting material failure behaviour. To this purpose, the selective laser melting manufacturing process is initially thermo‐mechanically simulated, followed by the mechanical analysis of the nonlinear core behaviour. The methodology is demonstrated in the case of open‐lattice body‐centred‐cubic (BCC) cellular cores.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.