In this work we present the results of the experimental studies of the dependence of the X-ray radiation on the temperature change speed of the lithium tantalate monocrystal in the pyroelectric source of the X-ray radiation. We have found an optimized linear temperature speed change pattern for the pyroelectric crystal designed for generation of the X-ray radiation with enhanced capabilities. The studies that were made open an opportunity to determine the most convenient conditions for generation of X-ray radiation with pyroelectric effect and for development of high-capacity pyroelectric X-ray radiation sources.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.