Introduction: The hepatocyte growth factor receptor mesenchymal-epithelial transition (MET) is reported to be a negative prognostic marker in EGFR-mutant NSCLC and involved in resistance to EGFR inhibitors. Emibetuzumab, a humanized immunoglobulin G4 monoclonal bivalent MET antibody, blocks ligand-dependent and ligand-independent hepatocyte growth factor/MET signaling. This phase 2 study compared erlotinib with and without emibetuzumab in first-line treatment of EGFR-mutant metastatic NSCLC.
Background: The purpose of this study was to compare dosimetric differences related to target volume and organs-at-risk (OAR) using 3D-conformal radiotherapy (3DCRT), volumetric modulated arc therapy (VMAT), TomoTherapy (Tomo), proton radiotherapy (PRT), and carbon ion radiotherapy (CIRT) as part of postoperative thymoma irradiation. Material and methods: This single-institutional analysis included 10 consecutive patients treated with adjuvant radiotherapy between December 2013 and September 2016. CT-datasets and respective RT-structures were anonymized and plans for all investigated RT modalities (3DCRT, VMAT, Tomo, PRT, CIRT) were optimized for a total dose of 50 Gy in 25 fractions. Comparisons between target volume and OAR dosimetric parameters were performed using the Wilcoxon rank-sum test. Results: The best target volume coverage (mean PTV V 95% for all patients) was observed for Tomo (97.9%), PRT (97.6%), and CIRT (96.6%) followed by VMAT (85.4%) and 3DCRT (74.7%). PRT and CIRT both significantly reduced mean doses to the lungs, breasts, heart, and esophagus, as well as the spinal cord maximum dose compared with photon modalities. Among photon-based techniques, VMAT showed improved OAR sparing over 3DCRT. Tomo was associated with considerable low-dose exposure to the lungs, breasts, and heart. Conclusions: Particle radiotherapy (PRT, CIRT) showed superior OAR sparing and optimal target volume coverage. The observed dosimetric advantages are expected to reduce toxicity rates. However, their clinical impact must be investigated prospectively.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.