Background: The impact on clinical outcomes of patient selection using perfusion imaging for endovascular thrombectomy (EVT) in patients with acute ischemic stroke presenting beyond 6 hours from onset remains undetermined in routine clinical practice. Methods: Patients from a national stroke registry that underwent EVT selected with or without perfusion imaging (noncontrast computed tomography/computed tomography angiography) in the early (<6 hours) and late (6–24 hours) time windows, between October 2015 and March 2020, were compared. The primary outcome was the ordinal shift in the modified Rankin Scale score at hospital discharge. Other outcomes included functional independence (modified Rankin Scale score ≤2) and in-hospital mortality, symptomatic intracerebral hemorrhage, successful reperfusion (Thrombolysis in Cerebral Infarction score 2b–3), early neurological deterioration, futile recanalization (modified Rankin Scale score 4–6 despite successful reperfusion) and procedural time metrics. Multivariable analyses were performed, adjusted for age, sex, baseline stroke severity, prestroke disability, intravenous thrombolysis, mode of anesthesia (Model 1) and including EVT technique, balloon guide catheter, and center (Model 2). Results: We included 4249 patients, 3203 in the early window (593 with perfusion versus 2610 without perfusion) and 1046 in the late window (378 with perfusion versus 668 without perfusion). Within the late window, patients with perfusion imaging had a shift towards better functional outcome at discharge compared with those without perfusion imaging (adjusted common odds ratio [OR], 1.45 [95% CI, 1.16–1.83]; P =0.001). There was no significant difference in functional independence (29.3% with perfusion versus 24.8% without; P =0.210) or in the safety outcome measures of symptomatic intracerebral hemorrhage ( P =0.53) and in-hospital mortality (10.6% with perfusion versus 14.3% without; P =0.053). In the early time window, patients with perfusion imaging had significantly improved odds of functional outcome (adjusted common OR, 1.51 [95% CI, 1.28–1.78]; P =0.0001) and functional independence (41.6% versus 33.6%, adjusted OR, 1.31 [95% CI, 1.08–1.59]; P =0.006). Perfusion imaging was associated with lower odds of futile recanalization in both time windows (late: adjusted OR, 0.70 [95% CI, 0.50–0.97]; P =0.034; early: adjusted OR, 0.80 [95% CI, 0.65–0.99]; P =0.047). Conclusions: In this real-world study, acquisition of perfusion imaging for EVT was associated with improvement in functional disability in the early and late time windows compared with nonperfusion neuroimaging. These indirect comparisons should be interpreted with caution while awaiting confirmatory data from prospective randomized trials.
Background The Silk Vista Baby (SVB) flow diverter (FDS) is the only FDS deliverable via a 0.017 inch microcatheter and is specifically designed for the distal vasculature. We sought to evaluate the safety and efficacy of the SVB. Materials and Methods We performed a retrospective review to identify SVB cases at 4 tertiary neurosurgical centres within the U.K. Clinical, procedural, angiographic and follow-up data were collected. Results We identified 60 patients (35 female, 58%) of average age 54 ± 10.5 (range 30–72) with 61 aneurysms, 50 (81.9%) located in the anterior circulation. The majority of the aneurysms treated were unruptured (46, 75.4%) and saccular (46, 75.4%). Dome size was 6.2 ± 6.2 mm (range 1–36mm) and parent vessel diameter was 2.3 ± 0.4 mm (range 1.2-3.3 mm). An average number of 1.07 devices were implanted. Coils or other devices were implanted in 14 aneurysms (23.3%). At last angiographic follow-up (n = 55), 7.5 ± 4.2 months post-procedure, 32 aneurysms (57.1%) were graded as RRC I, 7 (12.5%) RRC II, and 17 RRC III (30.4%). Clinical complications, excluding death, were seen in 4 patients (6.8%) including 1 delayed aneurysm rupture and 3 symptomatic ischaemic events. Only one patient had permanent morbidity (mRS 1). 3 patients died during follow-up (5.1%); 2 deaths were related to the aneurysms (3.4%) – one ruptured dissecting MCA aneurysm, and one giant partially thrombosed posterior circulation aneurysm. 93% of patients were mRS ≤ 2 at last follow-up. Conclusion The SVB has high rates of technical success and an acceptable safety profile. Distal aneurysms may occlude slower due to relative oversizing of the devices.
Endosaccular flow disruption is an innovative method of treating wide-necked complex aneurysms. Currently four types of devices have obtained the CE mark for use within Europe. These are the Woven EndoBridge device (WEB), the Luna Aneurysm Embolization System, the Medina Embolic Device (Medtronic), and the Contour Neurovascular System. The aim of this article is to provide an overview of these devices and to summarize the evidence in the literature pertaining to the treatment of intracranial aneurysms with them.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.