This study aimed to evaluate the inter-rater reliability of the Feline Grimace Scale (FGS) in cats undergoing dental extractions and the effects of the caregiver's presence on the FGS scores. Twenty-four cats (6 ± 3.3 years old; 4.9 ± 1.7 kg) undergoing oral treatment were included in a prospective, blinded, randomized, clinical study. They underwent treatment under general anesthesia (acepromazine-hydromorphone-propofol-isoflurane-meloxicam-local anesthetic blocks) at day 1 and were discharged at day 6. Images of cat faces were captured from video recordings with or without the caregiver's presence at 6 h postoperatively (day 1), day 6, and before and after rescue analgesia. Images were randomized and independently evaluated by four raters using the FGS [five action units (AU): ear position, orbital tightening, muzzle tension, whiskers change, and head position; score 0-2 for each]. Inter-rater reliability and the effects of the caregiver's presence were analyzed with intraclass correlation coefficient [single measures (95% confidence interval)] and the Wilcoxon signed-rank test, respectively (p < 0.05). A total of 91 images were scored. Total FGS scores showed good inter-rater reliability [0.84 (0.77-0.89)]. Reliability for each AU was: ears [0.68 (0.55-0.78)], orbital tightening [0.76 (0.65-0.84)], muzzle [0.56 (0.43-0.69)], whiskers [0.64 (0.50-0.76)], and head position [0.74 (0.63-0.82)]. The FGS scores were not different with [0.075 (0-0.325)] or without [0.088 (0-0.525)] the caregivers' presence (p = 0.12). The FGS is a reliable tool for pain assessment in cats undergoing dental extractions. The caregiver's presence did not affect FGS scores.
Background Pain is the leading cause of animal suffering, hence the importance of validated tools to ensure its appropriate evaluation and treatment. We aimed to test the psychometric properties of the short form of the Unesp-Botucatu Feline Pain Scale (UFEPS-SF) in eight languages. Methods The original scale was condensed from ten to four items. The content validation was performed by five specialists in veterinary anesthesia and analgesia. The English version of the scale was translated and back-translated into Chinese, French, German, Italian, Japanese, Portuguese and Spanish by fluent English and native speaker translators. Videos of the perioperative period of 30 cats submitted to ovariohysterectomy (preoperative, after surgery, after rescue analgesia and 24 h after surgery) were randomly evaluated twice (one-month interval) by one evaluator for each language unaware of the pain condition. After watching each video, the evaluators scored the unidimensional, UFEPS-SF and Glasgow composite multidimensional feline pain scales. Statistical analyses were carried out using R software for intra and interobserver reliability, principal component analysis, criteria concurrent and predictive validities, construct validity, item-total correlation, internal consistency, specificity, sensitivity, the definition of the intervention score for rescue analgesia and diagnostic uncertainty zone, according to the receiver operating characteristic (ROC) curve. Results UFEPS-SF intra- and inter-observer reliability were ≥0.92 and 0.84, respectively, for all observers. According to the principal component analysis, UFEPS-SF is a unidimensional scale. Concurrent criterion validity was confirmed by the high correlation between UFEPS-SF and all other scales (≥0.9). The total score and all items of UFEPS-SF increased after surgery (pain), decreased to baseline after analgesia and were intermediate at 24 h after surgery (moderate pain), confirming responsiveness and construct validity. Item total correlation of each item (0.68–0.83) confirmed that the items contributed homogeneously to the total score. Internal consistency was excellent (≥0.9) for all items. Both specificity (baseline) and sensitivity (after surgery) based on the Youden index was 99% (97–100%). The suggestive cut-off score for the administration of analgesia according to the ROC curve was ≥4 out of 12. The diagnostic uncertainty zone ranged from 3 to 4. The area under the curve of 0.99 indicated excellent discriminatory capacity of UFEPS-SF. Conclusions The UFEPS-SF and its items, assessed by experienced evaluators, demonstrated very good repeatability and reproducibility, content, criterion and construct validities, item-total correlation, internal consistency, excellent sensitivity and specificity and a cut-off point indicating the need for rescue analgesia in Chinese, French, English, German, Italian, Japanese, Portuguese and Spanish.
This study identified important areas of client communication regarding pain and its control in pets.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.