Background: Sensitive and easy-to-perform methods for the diagnosis of malaria are not yet available. Improving the limit of detection and following the requirements for certification are issues to be addressed in both endemic and non-endemic settings. The aim of this study was to test whether loop-mediated isothermal amplification of DNA (LAMP) may be an alternative to microscopy or real-time PCR for the screening of imported malaria cases in non-endemic area. Results: 310 blood samples associated with 829 suspected cases of imported malaria were tested during a one year period. Microscopy (thin and thick stained blood slides, reference standard) was used for the diagnosis. Real-time PCR was used as a standard of truth, and LAMP (Meridian Malaria Plus) was used as an index test in a prospective study conducted following the Standards for Reporting Diagnosis Accuracy Studies. In the 83 positive samples, species identification was P. falciparum (n = 66), P. ovale (n = 9), P. vivax (n = 3) P. malariae (n = 3) and 2 co-infections with P. falciparum + P.malariae. Using LAMP methods, 93 samples gave positive results, including 4 false-positives. Sensitivity, specificity, positive predictive value and negative predictive value for LAMP tests were 100%, 98.13%, 95.51%, and 100% compared to PCR. Conclusion: High negative predictive value, and limit of detection suggest that LAMP can be used for screening of imported malaria cases in non-endemic countries when expert microscopists are not immediately available. However, the rare occurrence of non-valid results and the need for species identification and quantification of positive samples preclude the use of LAMP as a single reference method.
Plasmodium vivax is the most widely distributed human malaria parasite. Outside sub-Saharan Africa, the proportion of P. vivax malaria is rising. A major cause for concern is the re-emergence of Plasmodium vivax in malaria-free areas. Oman, situated in the south-eastern corner of the Arabian Peninsula, has long been an area of vivax malaria transmission but no locally acquired cases were reported in 2004. However, local transmission has been registered in small outbreaks since 2007. In this study, a local outbreak of 54 cases over 50 days in 2014 was analyzed retrospectively and stained blood slides have been obtained for parasite identification and genotyping. The aim of this study was to identify the geographical origin of these cases, in an attempt to differentiate between imported cases and local transmission. Using circumsporozoite protein (csp), merozoite surface protein 1 (msp1), and merozoite surface protein 3 (msp3) markers for genotyping of parasite DNA obtained by scrapping off the surface of smears, genetic diversity and phylogenetic analysis were performed. The study found that the samples had very low genetic diversity, a temperate genotype, and a high genetic distance, with most of the reference strains coming from endemic countries. We conclude that a small outbreak of imported malaria is not associated with re-emergence of malaria transmission in Oman, as no new cases have been seen since the outbreak ended.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.