The umbilical venous catheter (UVC) is one of the most commonly used central lines in neonates. It can be easily inserted soon after birth providing stable intravenous access in infants requiring advanced resuscitation in the delivery room or needing medications, fluids, and parenteral nutrition during the 1st days of life. Resident training is crucial for UVC placement. The use of simulators allows trainees to gain practical experience and confidence in performing the procedure without risks for patients. UVCs are easy to insert, however when the procedure is performed without the use of ultrasound, there is a quite high risk, up to 40%, of non-central position. Ultrasound-guided UVC tip location is a simple and learnable technique and therefore should be widespread among all physicians. The feasibility of targeted training on the use of point-of-care ultrasound (POCUS) for UVC placement in the neonatal intensive care unit (NICU) among neonatal medical staff has been demonstrated. Conversely, UVC-related complications are very common and can sometimes be life-threatening. Despite UVCs being used by neonatologists for over 60 years, there are still no standard guidelines for assessment or monitoring of tip location, securement, management, or dwell time. This review article is an overview of the current knowledge and evidence available in the literature about UVCs. Our aim is to provide precise and updated recommendations on the use of this central line.
Objective
To propose an early lung ultrasound (LUS) score for the prediction of the need for respiratory assistance in newborns of gestational age (GA) ≥ 33 weeks presenting respiratory distress.
Study Design and Setting
Multicenter, prospective observational study in third‐level neonatal intensive care units.
Patient Selection
Infants with GA ≥ 33 + 0 weeks with respiratory distress within 3 h of life.
Methods
Three LUS for each patient were collected: within 3 h of life (T0), at 4–6 h of life (T1), and at the resolution of symptoms (T2). The primary aim was to assess the validity of the early LUS score in predicting the need for continuous positive airway pressure (CPAP). We also evaluated the validity of the score in predicting the need for surfactant, the scores' trend in our population, and any correlation with the duration of ventilation and oxygen therapy.
Results
Sixty‐two patients were enrolled in the study. The mean GA was 36 weeks. The receiver operating characteristic analysis for the LUS T0 and T1 yielded area under the curves of 0.91 and 0.82 in predicting the need for CPAP, respectively. LUS score cut off of 6 (sensitivity 84.8%, specificity 86.2%) and 5 (sensitivity 66.7%, specificity 100%) were calculated at T0 and T1, respectively. We found significant correlations between LUS score and respiratory assistance, surfactant administration, and SpO2/FiO2 ratio.
Conclusion
An early LUS score is a good noninvasive predictor of the need for respiratory assistance with CPAP and surfactant administration in newborns with GA ≥ 33 weeks.
Introduction: Epicutaneo-caval catheters (ECC) are pivotal for drug and fluid infusion in neonates. Given the intrinsic importance of the catheter for the patients’ health and the need to avoid stressful and painful procedures on premature or critically ill newborns with fragile and poor vein asset, it is clearly necessary an accurate bundle for ECC insertion and management to avoid complications that may lead to non-elective ECC removal. Among others, dislodgment is an acknowledged complication, and conventionally adopted fixing devices seem alone unsatisfying in relation to ECC securement. Object: To evaluate the usefulness of medical Cyanoacrylate Glue (CG) as a solution to strengthen conventional ECC securement. Methods: Since the use of CG has become part of our ECC insertion bundle in 2018, the present study compares all term and preterm neonates admitted in our NICU in 2018 who required an ECC for any cause (92 cases) with an historical cohort formed by all neonates who required an ECC in 2017 (80 patients). Results: CG added to usual securement devices is effective in reducing ECC accidental dislodgment. Moreover, it is easy and safe to apply and remove, limits bleeding and oozing at the puncture site, and may also be an effective antimicrobial mechanical barrier.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.