PurposeWe investigated the hypothesis that many total hip arthroplasty revisions that are classified as aseptic are in fact low-grade infections missed with routine diagnostics.MethodsIn 7 Dutch hospitals, 176 consecutive patients with the preoperative diagnosis of aseptic loosening of their total hip arthroplasty were enrolled. During surgery, between 14 and 20 tissue samples were obtained for culture, pathology, and broad-range 16S rRNA PCR with reverse line blot hybridization. Patients were classified as either not being infected, suspected of having infection, or infected according to strict, predefined criteria. Each patient had a follow-up visit after 1 year.Results7 patients were classified as infected, 4 of whom were not identified by routine culture. 15 additional patients were suspected of having infection. 20 of these 22 patients received a cemented prosthesis, fixated with antibiotic-loaded bone cement. All 22 patients received prophylactic systemic antibiotics. 7 of them reported complaints one year after surgery, but only one showed signs of early loosening. However, additional surgery was not performed in any of the patients.InterpretationAlthough the proportions were not as high as previously reported in the literature, between 4% and 13% of patients with the preoperative diagnosis of aseptic loosening were infected. However, as thorough debridement was performed during surgery and prophylactic antibiotics were used, the diagnosis of infection did not have any obvious clinical consequences, as most patients performed well at the 1-year follow-up. Whether this observation has implications for long-term implant survival remains to be seen.
Following revision of TKA and THA for aseptic diagnoses, around 10% of cases were found to have positive cultures. In the knee, such cases had inferior infection-free survival at two years compared with those with negative cultures; there was no difference between the groups following THA. Cite this article: Bone Joint J 2017;99-B:1482-9.
We recommend that an orthopaedic surgeon should choose an established cemented or cementless socket for hip replacement based on patient characteristics, knowledge, experience and preference.
Background The acetabular component has remained the weakest link in hip arthroplasty regarding achievement of long-term survival. Primary fixation is a prerequisite for long-term performance. For this reason, we investigated the stability of a unique cementless titanium-coated elastic monoblock socket and the influence of supplementary screw fixation.Patient and methods During 2006–2008, we performed a randomized controlled trial on 37 patients (mean age 63 years (SD 7), 22 females) in whom we implanted a cementless press-fit socket. The socket was implanted with additional screw fixation (group A, n = 19) and without additional screw fixation (group B, n = 18). Using radiostereometric analysis with a 2-year follow-up, we determined the stability of the socket. Clinically relevant migration was defined as > 1 mm translation and > 2º rotation. Clinical scores were determined.Results The sockets without screw fixation showed a statistically significantly higher proximal translation compared to the socket with additional screw fixation. However, this higher migration was below the clinically relevant threshold. The numbers of migratory sockets were not significantly different between groups. After the 2-year follow-up, there were no clinically relevant differences between groups A and B regarding the clinical scores. 1 patient dropped out of the study. In the others, no sockets were revised.Interpretation We found that additional screw fixation is not necessary to achieve stability of the cementless press-fit elastic RM socket. We saw no postoperative benefit or clinical effect of additional screw fixation.
The survival of acetabular components depends on several factors: wear, osteolysis and septic or aseptic loosening. Osteolysis seems to be the main cause for concern in cementless arthroplasties. Acetabular osteolysis results from particle debris and segmental unloading of acetabular bone by rigid sockets. We investigated a cementless elastic monoblock socket with regard to acetabular osteolysis and aseptic loosening in a cohort of young patients. We evaluated 158 hip arthroplasties with a minimum follow-up of ten years (ten to 18) and a mean age of 42 years (18–50). The overall revision rate at 14 years was 80% with a 98% survival rate for aseptic loosening. The mean polyethylene wear rate was 0.11 mm/year. Progressive acetabular osteolysis was seen in 3% of patients evaluated. In conclusion, we found low pelvic osteolysis rates, acceptable overall wear rates, satisfactory overall survival and excellent survival rates for aseptic loosening of a cementless elastic monoblock socket in patients younger than 50 years. Ongoing tribology developments and knowledge about acetabular bone adaptations behind acetabular implants will further lower wear and osteolysis rates and optimise survival rates of cementless sockets.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.