Compared with tricuspid AS, TAVR in bicuspid AS was associated with a similar prognosis, but lower device success rate. Procedural differences were observed in patients treated with the early-generation devices, whereas no differences were observed with the new-generation devices.
The clinical outcomes of TAVR in patients with bicuspid AS were favorable. New-generation devices were associated with less paravalvular leak and, hence, a higher device success rate than early-generation devices. (The Bicuspid Aortic Stenosis Following Transcatheter Aortic Valve Replacement Registry [Bicuspid TAVR]; NCT02394184).
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.